{"title":"CAR-15-GFST","description":"","products":[{"product_id":"lutron-car-15-gfst-al","title":"Lutron CAR-15-GFST-AL Claro Self-Testing Tamper Resistant 15A GFCI Receptacle, in Almond","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/Lutron-Gloss-Claro-Wallplates-s\/4072.htm\" style=\"outline: 0px;\"\u003eMatching Wallplate Sold Separately\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eThree provisions for providing protection:\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\u003ctable class=\"subpage_table\" width=\"100%\" cellpadding=\"5\" cellspacing=\"0\" style=\"font-size: 14px;\"\u003e\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd valign=\"top\" width=\"30%\"\u003eModel #\u003c\/td\u003e\n\u003ctd\u003eCAR-15-GFST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\u003ctd valign=\"top\"\u003eType\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eSelf-Testing Tamper Resistant GFCI Receptacles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd valign=\"top\"\u003eAmpere\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\u003ctd valign=\"top\"\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd valign=\"top\"\u003eStandards and Certifications\u003c\/td\u003e\n\u003ctd\u003eUL\/CSA\/NOM\/UL 943 Dust Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46793195192627,"sku":"Lutron-CAR-15-GFST-AL","price":61.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-CAR-15-GFST-AL-2.jpg?v=1737642876"},{"product_id":"lutron-car-15-gfst-bl","title":"Lutron CAR-15-GFST-BL Claro Self-Testing Tamper Resistant 15A GFCI Receptacle, in Black","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/Lutron-Gloss-Claro-Wallplates-s\/4072.htm\" style=\"outline: 0px;\"\u003eMatching Wallplate Sold Separately\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eThree provisions for providing protection:\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\u003ctable class=\"subpage_table\" style=\"font-size: 14px;\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\"\u003e\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd width=\"30%\" valign=\"top\"\u003eModel #\u003c\/td\u003e\n\u003ctd\u003eCAR-15-GFST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\u003ctd valign=\"top\"\u003eType\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eSelf-Testing Tamper Resistant GFCI Receptacles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd valign=\"top\"\u003eAmpere\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\u003ctd valign=\"top\"\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd valign=\"top\"\u003eStandards and Certifications\u003c\/td\u003e\n\u003ctd\u003eUL\/CSA\/NOM\/UL 943 Dust Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46793195258163,"sku":"Lutron-CAR-15-GFST-BL","price":61.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-CAR-15-GFST-BL-2.jpg?v=1737642892"},{"product_id":"lutron-car-15-gfst-br","title":"Lutron CAR-15-GFST-BR Claro Self-Testing Tamper Resistant 15A GFCI Receptacle, in Brown","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/Lutron-Gloss-Claro-Wallplates-s\/4072.htm\" style=\"outline: 0px;\"\u003eMatching Wallplate Sold Separately\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eThree provisions for providing protection:\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\u003ctable class=\"subpage_table\" width=\"100%\" cellpadding=\"5\" cellspacing=\"0\" style=\"font-size: 14px;\"\u003e\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd valign=\"top\" width=\"30%\"\u003eModel #\u003c\/td\u003e\n\u003ctd\u003eCAR-15-GFST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\u003ctd valign=\"top\"\u003eType\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eSelf-Testing Tamper Resistant GFCI Receptacles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd valign=\"top\"\u003eAmpere\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\u003ctd valign=\"top\"\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd valign=\"top\"\u003eStandards and Certifications\u003c\/td\u003e\n\u003ctd\u003eUL\/CSA\/NOM\/UL 943 Dust Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46793195618611,"sku":"Lutron-CAR-15-GFST-BR","price":61.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-CAR-15-GFST-BR-2.jpg?v=1737642908"},{"product_id":"lutron-car-15-gfst-gr","title":"Lutron CAR-15-GFST-GR Claro Self-Testing Tamper Resistant 15A GFCI Receptacle, in Gray","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/Lutron-Gloss-Claro-Wallplates-s\/4072.htm\" style=\"outline: 0px;\"\u003eMatching Wallplate Sold Separately\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eThree provisions for providing protection:\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\u003ctable class=\"subpage_table\" style=\"font-size: 14px;\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\"\u003e\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd width=\"30%\" valign=\"top\"\u003eModel #\u003c\/td\u003e\n\u003ctd\u003eCAR-15-GFST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\u003ctd valign=\"top\"\u003eType\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eSelf-Testing Tamper Resistant GFCI Receptacles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd valign=\"top\"\u003eAmpere\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\u003ctd valign=\"top\"\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd valign=\"top\"\u003eStandards and Certifications\u003c\/td\u003e\n\u003ctd\u003eUL\/CSA\/NOM\/UL 943 Dust Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46793195684147,"sku":"Lutron-CAR-15-GFST-GR","price":61.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-CAR-15-GFST-GR-2.jpg?v=1737642924"},{"product_id":"lutron-car-15-gfst-iv","title":"Lutron CAR-15-GFST-IV Claro Self-Testing Tamper Resistant 15A GFCI Receptacle, in Ivory","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/Lutron-Gloss-Claro-Wallplates-s\/4072.htm\" style=\"outline: 0px;\"\u003eMatching Wallplate Sold Separately\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eThree provisions for providing protection:\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\u003ctable class=\"subpage_table\" style=\"font-size: 14px;\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\"\u003e\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd width=\"30%\" valign=\"top\"\u003eModel #\u003c\/td\u003e\n\u003ctd\u003eCAR-15-GFST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\u003ctd valign=\"top\"\u003eType\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eSelf-Testing Tamper Resistant GFCI Receptacles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd valign=\"top\"\u003eAmpere\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\u003ctd valign=\"top\"\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd valign=\"top\"\u003eStandards and Certifications\u003c\/td\u003e\n\u003ctd\u003eUL\/CSA\/NOM\/UL 943 Dust Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46793196011827,"sku":"Lutron-CAR-15-GFST-IV","price":61.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-CAR-15-GFST-IV-2.jpg?v=1737642940"},{"product_id":"lutron-car-15-gfst-la","title":"Lutron CAR-15-GFST-LA Claro Self-Testing Tamper Resistant 15A GFCI Receptacle, in Light Almond","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/Lutron-Gloss-Claro-Wallplates-s\/4072.htm\" style=\"outline: 0px;\"\u003eMatching Wallplate Sold Separately\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eThree provisions for providing protection:\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\u003ctable class=\"subpage_table\" width=\"100%\" cellpadding=\"5\" cellspacing=\"0\" style=\"font-size: 14px;\"\u003e\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd valign=\"top\" width=\"30%\"\u003eModel #\u003c\/td\u003e\n\u003ctd\u003eCAR-15-GFST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\u003ctd valign=\"top\"\u003eType\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eSelf-Testing Tamper Resistant GFCI Receptacles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd valign=\"top\"\u003eAmpere\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\u003ctd valign=\"top\"\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd valign=\"top\"\u003eStandards and Certifications\u003c\/td\u003e\n\u003ctd\u003eUL\/CSA\/NOM\/UL 943 Dust Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46793196077363,"sku":"Lutron-CAR-15-GFST-LA","price":61.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-CAR-15-GFST-LA-2.jpg?v=1737642956"},{"product_id":"lutron-car-15-gfst-wh","title":"Lutron CAR-15-GFST-WH Claro Self-Testing Tamper Resistant 15A GFCI Receptacle, in White","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/Lutron-Gloss-Claro-Wallplates-s\/4072.htm\" style=\"outline: 0px none currentcolor;\"\u003eMatching Wallplate Sold Separately\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eThree provisions for providing protection:\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\u003ctable class=\"subpage_table\" style=\"font-size: 14px;\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\"\u003e\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd width=\"30%\" valign=\"top\"\u003eModel #\u003c\/td\u003e\n\u003ctd\u003eCAR-15-GFST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\u003ctd valign=\"top\"\u003eType\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eSelf-Testing Tamper Resistant GFCI Receptacles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd valign=\"top\"\u003eAmpere\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\u003ctd valign=\"top\"\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\u003ctd valign=\"top\"\u003eStandards and Certifications\u003c\/td\u003e\n\u003ctd\u003eUL\/CSA\/NOM\/UL 943 Dust Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46793196405043,"sku":"Lutron-CAR-15-GFST-WH","price":61.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-CAR-15-GFST-WH-2.jpg?v=1737642973"}],"url":"https:\/\/electricbargainstores.com\/collections\/car-15-gfst.oembed","provider":"Electric Bargain Store","version":"1.0","type":"link"}