{"title":"Dual-Lite Central Lighting Inverters","description":"","products":[{"product_id":"dual-lite-atsd","title":"Dual-Lite ATSD 120\/277VAV Auxilary Transfer Switch","description":"\u003cp\u003e\n\t\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\n\tThe ATSD auxiliary transfer switch works in conjunction with an emergency lighting inverter or an auxiliary generator to power switched or dimmed emergency lighting fixtures up to 3A. The auxiliary transfer senses the loss of normal power and bypasses the switch or dimmer, transferring the lighting load to a designated emergency power source, regardless of the switch or dimmer position. Recommended applications include: auditoriums, classrooms, or any other location with generator or inverter-supplied emergency lighting.\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cbr\u003e\n\t\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003e\n\tThe ATSD consists of relay switching circuitry and fusing in one compact galvanized steel case. The auxiliary transfer switch device is suitable for use indoor-dry or damp location fixture.\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cbr\u003e\n\t\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003cbr\u003e\n\tThe ATSD auxiliary transfer device does not affect normal fixture operation and comes fully assembled to mount in the fixture ballast channel. In addition to available wiring, the device requires a direct, unswitched connection to a generator or inverter-supplied emergency panel and an unswitched source on the same branch circuit as the switched supply. One auxiliary transfer switch device per fixture can be used to bypass fixture wall switch allowing the building generator to bring on switchable fixture and not just those on “night-light” circuits. (See diagram on second page of PDF Specification)\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cbr\u003e\n\t\u003cstrong\u003eIllumination\u003c\/strong\u003e\u003cbr\u003e\n\tThe ATSD auxiliary transfer switching device works in conjunction with an auxiliary generator or inverter power system to power existing fixtures for egress lighting regardless of fixture wall switch position.\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cbr\u003e\n\t\u003cstrong\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\n\tUL 924 Listed\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cbr\u003e\n\t\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\n\tUnit and Electronics: 5 years full\n\u003c\/p\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441574207795,"sku":"Dual-Lite-ATSD","price":296.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-ATSD-2.jpg?v=1734123028"},{"product_id":"dual-lite-atsd20","title":"Dual-Lite ATSD20 20 Amp Auxilary Transfer Switch","description":"\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\n  The ATSD20 works in conjunction with an emergency lighting inverter or auxiliary generator to power switched and dimmed emergency lighting loads up to 20 Amps. The device senses the loss of normal power and, in response, switches the lighting load to a designated emergency source. This allows for a switch or dimmer to be overridden\u003cbr\u003e\n  so that full emergency power can be provided to the designated fixtures, regardless of switch position. The switch is compatible with all lamp types, although HID type lamps are not recommended as the time to achieve full illumination may not be acceptable to NFPA 101 standards when switching to emergency power from an off position.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cb\u003e\n  Construction\u003c\/b\u003e\u003cbr\u003e\n  The ATSD20 enclosure and cover are constructed of 20 gauge steel with a gray paint finish and is surface mountable.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\n  \u003cstrong\u003eInstallation\u003c\/strong\u003e\u003cbr\u003e\n  The ATSD20 does not affect normal fixture operation and comes fully assembled for immediate installation. In addition to available wiring, the device requires a direct, unswitched connection to a normal power circuit and, depending on the application, an unswitched connection to a generator-supplied or central inverter system-supplied emergency panel. (See diagram on second page of PDF Specification)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\n  \u003cstrong\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\n  UL Damp location listed\u003cbr\u003e\n  UL 1008 Listed (Transfer Switch Equipment)\u003cbr\u003e\n  NFPA 101 Life Safety Code\u003cbr\u003e\n  NFPA 70 National Electrical Code\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\n  \u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\n  Unit and Electronics: 5 years full\u003c\/p\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441574240563,"sku":"Dual-Lite-ATSD20","price":417.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-ATSD20-2.jpg?v=1734123044"},{"product_id":"dual-lite-d208-27s120-208a2004","title":"Dual-Lite D208-27S120\/208-A2004 Single-Phase Central Lighting Inverter, 208VAC Input, 2.7KVA, 10-year VRLA Lead-Calcium, 120\/208VAC Output, 120VAC Output Circuit Breaker Voltage Rating, 20A, 4 Output Circuit Breaker","description":"\u003cb\u003ePRODUCT FAMILY SPECIFICATIONS\u003cbr\u003e\u003c\/b\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cb\u003eAPPLICATION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eIndoor Commercial\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003eIndoor Industrial\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/span\u003e\u003cb\u003eOPERATION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eAutomatic, programmable self-diagnostic \u003c\/span\u003eoperation\u003c\/li\u003e\n\u003cli\u003eWhen normal utility-supplied power is present, the LSN model central lighting inverter provides load-side line conditioning with \"brownout\" protection, and charges the system batteries when required.\u003c\/li\u003e\n\u003cli\u003eWhen utility-supplied power is interrupted, or the voltage varies from predetermined limits, the system will automatically and instantaneously transfer to emergency mode without interruption to connected loads.\u003c\/li\u003e\n\u003cli\u003eDC battery-derived emergency power is inverted to AC power and supplied in a pure sine wave output form for 90 minutes (standard run time).\u003c\/li\u003e\n\u003cli\u003eA low voltage battery disconnect circuit prevents \"deep discharge\" damage to the batteries during prolonged power outages. When normal power is restored the system will automatically restart, providing power to connected loads and recharging the batteries.\u003c\/li\u003e\n\u003cli\u003eThe charging circuit will bring the batteries to full recharge within UL time standards.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cb\u003eCONSTRUCTION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eSteel Cabinet\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003eLight grey paint finish\u003c\/li\u003e\n\u003cli\u003eLocking cabinetry and password-protected user interface for security\u003c\/li\u003e\n\u003cli\u003eLouvers at front and top of cabinet allow venting.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cb\u003eINSTALLATION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eInput power entry point is from the \u003c\/span\u003ecabinet top.\u003c\/li\u003e\n\u003cli\u003eBottom channels for lifting straps\u003c\/li\u003e\n\u003cli\u003eWall brackets for anchoring.\u003c\/li\u003e\n\u003cli\u003eServicing is accessible from cabinet front.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eCERTIFICATIONS\/COMPLIANCES\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eUL 924 Listed, Emergency Lighting and \u003c\/span\u003ePower Equipment (standard 90 minute run time), type S battery, all voltages except 347V\u003c\/li\u003e\n\u003cli\u003eUL \u0026amp; CUL 1778 Listed, Uninterruptible Power Supply Equipment (alternate run times; type G batteries; 347V input\/output)\u003c\/li\u003e\n\u003cli\u003eANSI C62.41: ANSI C62.45 (Cat. A \u0026amp; B)\u003c\/li\u003e\n\u003cli\u003eFCC class A\u003c\/li\u003e\n\u003cli\u003eNational Electrical Code (NFPA 70)\u003c\/li\u003e\n\u003cli\u003eLife Safety Code (NFPA 101)\u003c\/li\u003e\n\u003cli\u003eNFPA 111 (Stored Emergency Power Supply Systems - SEPSS)\u003c\/li\u003e\n\u003cli\u003eNEMA Type 1 Cabinetry\u003c\/li\u003e\n\u003cli\u003eOSHA, state and local codes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003cb\u003eWARRANTY\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTwo years full on all components from date \u003c\/span\u003eof shipment when a Factory Start-Up is performed; one year full when a Factory Start-Up is not performed.\u003c\/li\u003e\n\u003cli\u003eBatteries are covered under a separate warranty:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan\u003e        \u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/dual-lite-LSN-D-Series-battery-warranty-information_ff710a2a-9e21-4320-9b55-8fe88fd66b17.jpg?v=1761762803\" style=\"background-color: initial; letter-spacing: 0px;\"\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eBatteries must be connected to an energized charging circuit within 90 days from date of shipment or warranty is void.\u003c\/li\u003e\n\u003cli\u003eStart-Up must be performed by an Authorized Service Center within 6 months of inverter shipment and will increase the inverter warranty to 2 years. Order quantity of 1 per system. Systems powered up by others are done so at their own risk.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/dual-lite-LSN-D-Series-ordering-information_b6201431-e64a-47ef-910f-0665230e94f9.jpg?v=1761762805\"\u003e\n\u003c\/div\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441580990771,"sku":"Dual-Lite-D208-27S120-208A2004","price":36790.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-D208-27S120-208A2004-2.jpg?v=1734123949"},{"product_id":"dual-lite-dls-400-120","title":"Dual-Lite DLS-400-120 400W Single-Phase Central Lighting Inverter120V, Normally On Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\n  Designed for indoor installation in commercial or industrial applications.\u003cbr\u003e\n  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\n  When normal utility-supplied power is present, the Synchron central lighting inverter allows utility power to pass through to the connected load and charges the system batteries as required. When utilitysupplied power is interrupted, the system will automatically and instantaneously transfer to emergency mode without interruption to connected loads. DC battery-derived emergency power is inverted to AC power and supplied in a pure sine wave output form for 90 minutes (standard run time).\u003cbr\u003e\n  A low voltage battery disconnect circuit prevents “deep discharge” damage to the batteries during prolonged power outages. When normal power is restored the system will automatically restart, providing power to connected loads and recharging the batteries. The charging circuit will bring the batteries to full recharge within UL time standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003e\n  The Synchron cabinet is constructed of NEMA 1 rated, painted steel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003cbr\u003e\n  Input power entry point is from the cabinet top. Unit supplied with wall brackets for anchoring and features front service entry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\n  UL 924 Listed, Emergency Lighting and Power Equipment\u003cbr\u003e\n  (standard 90 minute run time)\u003cbr\u003e\n  National Electrical Code (NFPA 70)\u003cbr\u003e\n  Life Safety Code (NFPA 101)\u003cbr\u003e\n  OSHA, state and local codes\u003cbr\u003e\n  Made in U.S.A.\u003cbr\u003e\n  Factory Startup\u003cbr\u003e\n  Use accessory number FSS when ordering\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\n  Two years full on all components from date of shipment when a Factory Start-Up is ordered; one year full when a Factory Start-Up is not ordered.\u003cbr\u003e\nOne year full, 9 years pro-rata for batteries.\u003c\/p\u003e\n\u003cb\u003eORDERING INFORMATION\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/DLS-ordering-information_1a15086f-938a-4865-9908-9854ef49f193.jpg?v=1761762869\"\u003e\u003c\/b\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441581023539,"sku":"Dual-Lite-DLS-400-120","price":7094.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-DLS-400-120-2.jpg?v=1734124004"},{"product_id":"dual-lite-dls-400-277","title":"Dual-Lite DLS-400-277 400W Single-Phase Central Lighting Inverter277V, Normally On Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\n  Designed for indoor installation in commercial or industrial applications.\u003cbr\u003e\n  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\n  When normal utility-supplied power is present, the Synchron central lighting inverter allows utility power to pass through to the connected load and charges the system batteries as required. When utilitysupplied power is interrupted, the system will automatically and instantaneously transfer to emergency mode without interruption to connected loads. DC battery-derived emergency power is inverted to AC power and supplied in a pure sine wave output form for 90 minutes (standard run time).\u003cbr\u003e\n  A low voltage battery disconnect circuit prevents “deep discharge” damage to the batteries during prolonged power outages. When normal power is restored the system will automatically restart, providing power to connected loads and recharging the batteries. The charging circuit will bring the batteries to full recharge within UL time standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003e\n  The Synchron cabinet is constructed of NEMA 1 rated, painted steel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003cbr\u003e\n  Input power entry point is from the cabinet top. Unit supplied with wall brackets for anchoring and features front service entry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\n  UL 924 Listed, Emergency Lighting and Power Equipment\u003cbr\u003e\n  (standard 90 minute run time)\u003cbr\u003e\n  National Electrical Code (NFPA 70)\u003cbr\u003e\n  Life Safety Code (NFPA 101)\u003cbr\u003e\n  OSHA, state and local codes\u003cbr\u003e\n  Made in U.S.A.\u003cbr\u003e\n  Factory Startup\u003cbr\u003e\n  Use accessory number FSS when ordering\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\n  Two years full on all components from date of shipment when a Factory Start-Up is ordered; one year full when a Factory Start-Up is not ordered.\u003cbr\u003e\nOne year full, 9 years pro-rata for batteries.\u003c\/p\u003e\n\u003cb\u003eORDERING INFORMATION\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/DLS-ordering-information_1a15086f-938a-4865-9908-9854ef49f193.jpg?v=1761762869\"\u003e\u003c\/b\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441581056307,"sku":"Dual-Lite-DLS-400-277","price":7094.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-DLS-400-277-2.jpg?v=1734124021"},{"product_id":"dual-lite-dls-525-120","title":"Dual-Lite DLS-525-120 525W Single-Phase Central Lighting Inverter120V, Normally On Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\n  Designed for indoor installation in commercial or industrial applications.\u003cbr\u003e\n  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\n  When normal utility-supplied power is present, the Synchron central lighting inverter allows utility power to pass through to the connected load and charges the system batteries as required. When utilitysupplied power is interrupted, the system will automatically and instantaneously transfer to emergency mode without interruption to connected loads. DC battery-derived emergency power is inverted to AC power and supplied in a pure sine wave output form for 90 minutes (standard run time).\u003cbr\u003e\n  A low voltage battery disconnect circuit prevents “deep discharge” damage to the batteries during prolonged power outages. When normal power is restored the system will automatically restart, providing power to connected loads and recharging the batteries. The charging circuit will bring the batteries to full recharge within UL time standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003e\n  The Synchron cabinet is constructed of NEMA 1 rated, painted steel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003cbr\u003e\n  Input power entry point is from the cabinet top. Unit supplied with wall brackets for anchoring and features front service entry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\n  UL 924 Listed, Emergency Lighting and Power Equipment\u003cbr\u003e\n  (standard 90 minute run time)\u003cbr\u003e\n  National Electrical Code (NFPA 70)\u003cbr\u003e\n  Life Safety Code (NFPA 101)\u003cbr\u003e\n  OSHA, state and local codes\u003cbr\u003e\n  Made in U.S.A.\u003cbr\u003e\n  Factory Startup\u003cbr\u003e\n  Use accessory number FSS when ordering\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\n  Two years full on all components from date of shipment when a Factory Start-Up is ordered; one year full when a Factory Start-Up is not ordered.\u003cbr\u003e\nOne year full, 9 years pro-rata for batteries.\u003c\/p\u003e\n\u003cb\u003eORDERING INFORMATION\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/DLS-ordering-information_1a15086f-938a-4865-9908-9854ef49f193.jpg?v=1761762869\"\u003e\u003c\/b\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441581121843,"sku":"Dual-Lite-DLS-525-120","price":8783.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-DLS-525-120-2.jpg?v=1734124037"},{"product_id":"dual-lite-dls-525-277","title":"Dual-Lite DLS-525-277 525W Single-Phase Central Lighting Inverter277V, Normally On Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\n  Designed for indoor installation in commercial or industrial applications.\u003cbr\u003e\n  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\n  When normal utility-supplied power is present, the Synchron central lighting inverter allows utility power to pass through to the connected load and charges the system batteries as required. When utilitysupplied power is interrupted, the system will automatically and instantaneously transfer to emergency mode without interruption to connected loads. DC battery-derived emergency power is inverted to AC power and supplied in a pure sine wave output form for 90 minutes (standard run time).\u003cbr\u003e\n  A low voltage battery disconnect circuit prevents “deep discharge” damage to the batteries during prolonged power outages. When normal power is restored the system will automatically restart, providing power to connected loads and recharging the batteries. The charging circuit will bring the batteries to full recharge within UL time standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003e\n  The Synchron cabinet is constructed of NEMA 1 rated, painted steel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003cbr\u003e\n  Input power entry point is from the cabinet top. Unit supplied with wall brackets for anchoring and features front service entry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\n  UL 924 Listed, Emergency Lighting and Power Equipment\u003cbr\u003e\n  (standard 90 minute run time)\u003cbr\u003e\n  National Electrical Code (NFPA 70)\u003cbr\u003e\n  Life Safety Code (NFPA 101)\u003cbr\u003e\n  OSHA, state and local codes\u003cbr\u003e\n  Made in U.S.A.\u003cbr\u003e\n  Factory Startup\u003cbr\u003e\n  Use accessory number FSS when ordering\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\n  Two years full on all components from date of shipment when a Factory Start-Up is ordered; one year full when a Factory Start-Up is not ordered.\u003cbr\u003e\nOne year full, 9 years pro-rata for batteries.\u003c\/p\u003e\n\u003cb\u003eORDERING INFORMATION\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/DLS-ordering-information_1a15086f-938a-4865-9908-9854ef49f193.jpg?v=1761762869\"\u003e\u003c\/b\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441582072115,"sku":"Dual-Lite-DLS-525-277","price":8783.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-DLS-525-277-2.jpg?v=1734124053"},{"product_id":"dual-lite-lg125s","title":"Dual-Lite LG125S LiteGear 125VA\/110W Single-Phase Central Lighting Inverter, Surface Wall Mount","description":"\u003cp\u003e\u003cstrong\u003eApplication  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for indoor installation in commercial or industrial applications.  Emergency AC power is supplied to lighting fixtures equipped with  incandescent, linear fluorescent, compact fluorescent or LED lamps. The  lighting load can be installed at a distance of up to 1,000 feet from the  LiteGear® central lighting inverter. Observe all required AC  conductor sizing requirements. When using LED lamps, consider LED  in-rush current in load calculations. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen normal utility supplied power is interrupted, the LiteGear®  Series unit will automatically transfer to emergency mode in less than  2-seconds and begin supplying inverted battery-derived AC power to  the load for 90 minutes. The unit is capable of operating normally on,  normally off or switched loads. A low voltage battery disconnect circuit  will prevent “deep discharge” damage to the battery. The charging  circuit will bring the batteries to full recharge within UL time standards.  A “brownout” circuit will automatically transfer the unit to emergency  power if the utility voltage falls to a pre-determined “low line” limit.  125VA\/110W and 250VA\/220W versions provide pure sine wave output.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LiteGear® enclosure and cover are constructed of heavy-duty,  steel with a white powder-coat paint finish. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUL 924 (Emergency Lighting)  UL 2043 (Plenum Air Handling Spaces) for LG125T  Life Safety Code (NFPA 101)  National Electrical Code (NFPA 70)  State and Local Code compliant  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUnit and Electronics: 3 years full* \u003c\/li\u003e\n  \u003cli\u003eSpectron® Model Unit and Electronics: 5 years full* \u003c\/li\u003e\n  \u003cli\u003eSLA Lead Calcium Battery: 3 years full, 7 years pro-rata\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LG-ordering-information_0822409d-cc92-4920-914d-a4c611e1f768.jpg?v=1761764861\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441726611763,"sku":"Dual-Lite-LG125S","price":995.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LG125S-2.jpg?v=1734126705"},{"product_id":"dual-lite-lg125si","title":"Dual-Lite LG125SI LiteGear 125VA\/110W Single-Phase Central Lighting Inverter, Surface Wall Mount, Self Testing\/ Diagnostics","description":"\u003cp\u003e\n \u003cstrong\u003eApplication  \u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Designed for indoor installation in commercial or industrial applications.  Emergency AC power is supplied to lighting fixtures equipped with  incandescent, linear fluorescent, compact fluorescent or LED lamps. The  lighting load can be installed at a distance of up to 1,000 feet from the  LiteGear central lighting inverter. Observe all required AC  conductor sizing requirements. When using LED lamps, consider LED  in-rush current in load calculations.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eOperation  \u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n When normal utility supplied power is interrupted, the LiteGear Series unit will automatically transfer to emergency mode in less than  2-seconds and begin supplying inverted battery-derived AC power to  the load for 90 minutes. The unit is capable of operating normally on,  normally off or switched loads. A low voltage battery disconnect circuit  will prevent ?deep discharge? damage to the battery. The charging  circuit will bring the batteries to full recharge within UL time standards.  A ?brownout? circuit will automatically transfer the unit to emergency  power if the utility voltage falls to a pre-determined \"low line\" limit.  125VA\/110W and 250VA\/220W versions provide pure sine wave output.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eConstruction  \u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n The LiteGear enclosure and cover are constructed of heavy-duty,  steel with a white powder-coat paint finish.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCompliances  \u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n UL 924 (Emergency Lighting)  UL 2043 (Plenum Air Handling Spaces) for LG125T  Life Safety Code (NFPA 101)  National Electrical Code (NFPA 70)  State and Local Code compliant\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty  \u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUnit and Electronics: 3 years full* \u003c\/li\u003e\n \u003cli\u003eSpectron Model Unit and Electronics: 5 years full* \u003c\/li\u003e\n \u003cli\u003eSLA Lead Calcium Battery: 3 years full, 7 years pro-rata\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LG-ordering-information_0822409d-cc92-4920-914d-a4c611e1f768.jpg?v=1761764861\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441727234355,"sku":"Dual-lite-LG125SI","price":2671.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-lite-LG125SI-2.jpg?v=1734126724"},{"product_id":"dual-lite-lg125t","title":"Dual-Lite LG125T LiteGear 125VA\/110W Single-Phase Central Lighting Inverter, Surface Recessed Ceiling T-Grid Mount","description":"\u003cp\u003e\u003cstrong\u003eApplication  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for indoor installation in commercial or industrial applications.  Emergency AC power is supplied to lighting fixtures equipped with  incandescent, linear fluorescent, compact fluorescent or LED lamps. The  lighting load can be installed at a distance of up to 1,000 feet from the  LiteGear® central lighting inverter. Observe all required AC  conductor sizing requirements. When using LED lamps, consider LED  in-rush current in load calculations. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen normal utility supplied power is interrupted, the LiteGear®  Series unit will automatically transfer to emergency mode in less than  2-seconds and begin supplying inverted battery-derived AC power to  the load for 90 minutes. The unit is capable of operating normally on,  normally off or switched loads. A low voltage battery disconnect circuit  will prevent “deep discharge” damage to the battery. The charging  circuit will bring the batteries to full recharge within UL time standards.  A “brownout” circuit will automatically transfer the unit to emergency  power if the utility voltage falls to a pre-determined “low line” limit.  125VA\/110W and 250VA\/220W versions provide pure sine wave output.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LiteGear® enclosure and cover are constructed of heavy-duty,  steel with a white powder-coat paint finish. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUL 924 (Emergency Lighting)  UL 2043 (Plenum Air Handling Spaces) for LG125T  Life Safety Code (NFPA 101)  National Electrical Code (NFPA 70)  State and Local Code compliant  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUnit and Electronics: 3 years full* \u003c\/li\u003e\n  \u003cli\u003eSpectron® Model Unit and Electronics: 5 years full* \u003c\/li\u003e\n  \u003cli\u003eSLA Lead Calcium Battery: 3 years full, 7 years pro-rata\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LG-ordering-information_0822409d-cc92-4920-914d-a4c611e1f768.jpg?v=1761764861\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441727889715,"sku":"Dual-Lite-LG125T","price":1182.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LG125T-2.jpg?v=1734126740"},{"product_id":"dual-lite-lg1s","title":"Dual-Lite LG1S LiteGear 100VA\/W Surface Wall Mount Compact Central Lighting Inverter","description":"\u003cp\u003e\u003cstrong\u003eApplication  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for indoor installation in commercial or industrial applications.  Emergency AC power is supplied to lighting fixtures equipped with  incandescent, linear fluorescent, compact fluorescent or LED lamps. The  lighting load can be installed at a distance of up to 1,000 feet from the  LiteGear® central lighting inverter. Observe all required AC  conductor sizing requirements. When using LED lamps, consider LED  in-rush current in load calculations. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen normal utility supplied power is interrupted, the LiteGear®  Series unit will automatically transfer to emergency mode in less than  2-seconds and begin supplying inverted battery-derived AC power to  the load for 90 minutes. The unit is capable of operating normally on,  normally off or switched loads. A low voltage battery disconnect circuit  will prevent “deep discharge” damage to the battery. The charging  circuit will bring the batteries to full recharge within UL time standards.  A “brownout” circuit will automatically transfer the unit to emergency  power if the utility voltage falls to a pre-determined “low line” limit.  125VA\/110W and 250VA\/220W versions provide pure sine wave output.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LiteGear® enclosure and cover are constructed of heavy-duty,  steel with a white powder-coat paint finish. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUL 924 (Emergency Lighting)  UL 2043 (Plenum Air Handling Spaces) for LG125T  Life Safety Code (NFPA 101)  National Electrical Code (NFPA 70)  State and Local Code compliant  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUnit and Electronics: 3 years full* \u003c\/li\u003e\n  \u003cli\u003eSpectron® Model Unit and Electronics: 5 years full* \u003c\/li\u003e\n  \u003cli\u003eSLA Lead Calcium Battery: 3 years full, 7 years pro-rata\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LG-ordering-information_0822409d-cc92-4920-914d-a4c611e1f768.jpg?v=1761764861\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441728512307,"sku":"Dual-Lite-LG1S","price":1055.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LG1S-2.jpg?v=1734126756"},{"product_id":"dual-lite-lg1t","title":"Dual-Lite LG1T 100VA\/W Recessed T-grid Ceiling Mount, Compact Central Lighting Inverter, White Finish","description":"\u003cp\u003e\u003cstrong\u003eApplication  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for indoor installation in commercial or industrial applications.  Emergency AC power is supplied to lighting fixtures equipped with  incandescent, linear fluorescent, compact fluorescent or LED lamps. The  lighting load can be installed at a distance of up to 1,000 feet from the  LiteGear® central lighting inverter. Observe all required AC  conductor sizing requirements. When using LED lamps, consider LED  in-rush current in load calculations. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen normal utility supplied power is interrupted, the LiteGear®  Series unit will automatically transfer to emergency mode in less than  2-seconds and begin supplying inverted battery-derived AC power to  the load for 90 minutes. The unit is capable of operating normally on,  normally off or switched loads. A low voltage battery disconnect circuit  will prevent “deep discharge” damage to the battery. The charging  circuit will bring the batteries to full recharge within UL time standards.  A “brownout” circuit will automatically transfer the unit to emergency  power if the utility voltage falls to a pre-determined “low line” limit.  125VA\/110W and 250VA\/220W versions provide pure sine wave output.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LiteGear® enclosure and cover are constructed of heavy-duty,  steel with a white powder-coat paint finish. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUL 924 (Emergency Lighting)  UL 2043 (Plenum Air Handling Spaces) for LG125T  Life Safety Code (NFPA 101)  National Electrical Code (NFPA 70)  State and Local Code compliant  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUnit and Electronics: 3 years full* \u003c\/li\u003e\n  \u003cli\u003eSpectron® Model Unit and Electronics: 5 years full* \u003c\/li\u003e\n  \u003cli\u003eSLA Lead Calcium Battery: 3 years full, 7 years pro-rata\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LG-ordering-information_0822409d-cc92-4920-914d-a4c611e1f768.jpg?v=1761764861\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441729134899,"sku":"Dual-Lite-LG1T","price":896.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LG1T-2.jpg?v=1734126771"},{"product_id":"dual-lite-lg250s","title":"Dual-Lite LG250S LiteGear 250VA\/W Single-Phase Central Lighting Inverter, Surface Wall Mount","description":"\u003cp\u003e\u003cstrong\u003eApplication  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for indoor installation in commercial or industrial applications.  Emergency AC power is supplied to lighting fixtures equipped with  incandescent, linear fluorescent, compact fluorescent or LED lamps. The  lighting load can be installed at a distance of up to 1,000 feet from the  LiteGear® central lighting inverter. Observe all required AC  conductor sizing requirements. When using LED lamps, consider LED  in-rush current in load calculations. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen normal utility supplied power is interrupted, the LiteGear®  Series unit will automatically transfer to emergency mode in less than  2-seconds and begin supplying inverted battery-derived AC power to  the load for 90 minutes. The unit is capable of operating normally on,  normally off or switched loads. A low voltage battery disconnect circuit  will prevent “deep discharge” damage to the battery. The charging  circuit will bring the batteries to full recharge within UL time standards.  A “brownout” circuit will automatically transfer the unit to emergency  power if the utility voltage falls to a pre-determined “low line” limit.  125VA\/110W and 250VA\/220W versions provide pure sine wave output.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LiteGear® enclosure and cover are constructed of heavy-duty,  steel with a white powder-coat paint finish. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUL 924 (Emergency Lighting)  UL 2043 (Plenum Air Handling Spaces) for LG125T  Life Safety Code (NFPA 101)  National Electrical Code (NFPA 70)  State and Local Code compliant  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUnit and Electronics: 3 years full* \u003c\/li\u003e\n  \u003cli\u003eSpectron® Model Unit and Electronics: 5 years full* \u003c\/li\u003e\n  \u003cli\u003eSLA Lead Calcium Battery: 3 years full, 7 years pro-rata\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LG-ordering-information_0822409d-cc92-4920-914d-a4c611e1f768.jpg?v=1761764861\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441729462579,"sku":"Dual-Lite-LG250S","price":1928.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LG250S-2.jpg?v=1734126786"},{"product_id":"dual-lite-lg250si","title":"Dual-Lite LG250SI LiteGear 250VA\/W Single-Phase Central Lighting Inverter, Surface Wall Mount, With Spectron Self Testing","description":"\u003cp\u003e\u003cstrong\u003eApplication  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for indoor installation in commercial or industrial applications.  Emergency AC power is supplied to lighting fixtures equipped with  incandescent, linear fluorescent, compact fluorescent or LED lamps. The  lighting load can be installed at a distance of up to 1,000 feet from the  LiteGear® central lighting inverter. Observe all required AC  conductor sizing requirements. When using LED lamps, consider LED  in-rush current in load calculations. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen normal utility supplied power is interrupted, the LiteGear®  Series unit will automatically transfer to emergency mode in less than  2-seconds and begin supplying inverted battery-derived AC power to  the load for 90 minutes. The unit is capable of operating normally on,  normally off or switched loads. A low voltage battery disconnect circuit  will prevent “deep discharge” damage to the battery. The charging  circuit will bring the batteries to full recharge within UL time standards.  A “brownout” circuit will automatically transfer the unit to emergency  power if the utility voltage falls to a pre-determined “low line” limit.  125VA\/110W and 250VA\/220W versions provide pure sine wave output.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LiteGear® enclosure and cover are constructed of heavy-duty,  steel with a white powder-coat paint finish. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUL 924 (Emergency Lighting)  UL 2043 (Plenum Air Handling Spaces) for LG125T  Life Safety Code (NFPA 101)  National Electrical Code (NFPA 70)  State and Local Code compliant  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUnit and Electronics: 3 years full* \u003c\/li\u003e\n  \u003cli\u003eSpectron® Model Unit and Electronics: 5 years full* \u003c\/li\u003e\n  \u003cli\u003eSLA Lead Calcium Battery: 3 years full, 7 years pro-rata\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LG-ordering-information_0822409d-cc92-4920-914d-a4c611e1f768.jpg?v=1761764861\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441729823027,"sku":"Dual-Lite-LG250SI","price":3191.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LG250SI-2.jpg?v=1734126802"},{"product_id":"dual-lite-lg2s","title":"Dual-Lite LG2S LiteGear 250VA\/W Surface Wall Mount Compact Central Lighting Inverter","description":"\u003cp\u003e\u003cstrong\u003eApplication  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for indoor installation in commercial or industrial applications.  Emergency AC power is supplied to lighting fixtures equipped with  incandescent, linear fluorescent, compact fluorescent or LED lamps. The  lighting load can be installed at a distance of up to 1,000 feet from the  LiteGear® central lighting inverter. Observe all required AC  conductor sizing requirements. When using LED lamps, consider LED  in-rush current in load calculations. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen normal utility supplied power is interrupted, the LiteGear®  Series unit will automatically transfer to emergency mode in less than  2-seconds and begin supplying inverted battery-derived AC power to  the load for 90 minutes. The unit is capable of operating normally on,  normally off or switched loads. A low voltage battery disconnect circuit  will prevent “deep discharge” damage to the battery. The charging  circuit will bring the batteries to full recharge within UL time standards.  A “brownout” circuit will automatically transfer the unit to emergency  power if the utility voltage falls to a pre-determined “low line” limit.  125VA\/110W and 250VA\/220W versions provide pure sine wave output.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LiteGear® enclosure and cover are constructed of heavy-duty,  steel with a white powder-coat paint finish. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUL 924 (Emergency Lighting)  UL 2043 (Plenum Air Handling Spaces) for LG125T  Life Safety Code (NFPA 101)  National Electrical Code (NFPA 70)  State and Local Code compliant  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUnit and Electronics: 3 years full* \u003c\/li\u003e\n  \u003cli\u003eSpectron® Model Unit and Electronics: 5 years full* \u003c\/li\u003e\n  \u003cli\u003eSLA Lead Calcium Battery: 3 years full, 7 years pro-rata\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LG-ordering-information_0822409d-cc92-4920-914d-a4c611e1f768.jpg?v=1761764861\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441730478387,"sku":"Dual-Lite-LG2S","price":1841.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LG2S-2.jpg?v=1734126818"},{"product_id":"dual-lite-lg2si","title":"Dual-Lite LG2SI LiteGear 250VA\/W Surface Wall Mount Compact Central Lighting Inverter with Sprectron, White Finish","description":"\u003cp\u003e\u003cstrong\u003eApplication  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for indoor installation in commercial or industrial applications.  Emergency AC power is supplied to lighting fixtures equipped with  incandescent, linear fluorescent, compact fluorescent or LED lamps. The  lighting load can be installed at a distance of up to 1,000 feet from the  LiteGear® central lighting inverter. Observe all required AC  conductor sizing requirements. When using LED lamps, consider LED  in-rush current in load calculations. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen normal utility supplied power is interrupted, the LiteGear®  Series unit will automatically transfer to emergency mode in less than  2-seconds and begin supplying inverted battery-derived AC power to  the load for 90 minutes. The unit is capable of operating normally on,  normally off or switched loads. A low voltage battery disconnect circuit  will prevent “deep discharge” damage to the battery. The charging  circuit will bring the batteries to full recharge within UL time standards.  A “brownout” circuit will automatically transfer the unit to emergency  power if the utility voltage falls to a pre-determined “low line” limit.  125VA\/110W and 250VA\/220W versions provide pure sine wave output.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LiteGear® enclosure and cover are constructed of heavy-duty,  steel with a white powder-coat paint finish. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUL 924 (Emergency Lighting)  UL 2043 (Plenum Air Handling Spaces) for LG125T  Life Safety Code (NFPA 101)  National Electrical Code (NFPA 70)  State and Local Code compliant  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUnit and Electronics: 3 years full* \u003c\/li\u003e\n  \u003cli\u003eSpectron® Model Unit and Electronics: 5 years full* \u003c\/li\u003e\n  \u003cli\u003eSLA Lead Calcium Battery: 3 years full, 7 years pro-rata\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LG-ordering-information_0822409d-cc92-4920-914d-a4c611e1f768.jpg?v=1761764861\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441731625267,"sku":"Dual-Lite-LG2SI","price":2257.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LG2SI-2.jpg?v=1734126833"},{"product_id":"dual-lite-lg375si","title":"Dual-Lite LG375SI LiteGear 375VA\/W Single-Phase Central Lighting Inverter, Surface Wall Mount, With Spectron Self Testing","description":"\u003cb\u003ePRODUCT SPECIFICATIONS\u003cbr\u003eAPPLICATION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eDesigned for indoor installation in\ncommercial or industrial applications.\u003c\/li\u003e\n\u003cli\u003eEmergency AC power is supplied to lighting\nfixtures equipped with incandescent,\nlinear fluorescent, compact fluorescent\nor LED lamps\u003c\/li\u003e\n\u003cli\u003eThe lighting load can be installed at a\ndistance of up to 1,000 feet from the\nLiteGear central lighting inverter\u003c\/li\u003e\n\u003cli\u003eObserve all required AC conductor\nsizing requirements\u003c\/li\u003e\n\u003cli\u003eWhen using LED lamps, consider LED in-rush\ncurrent in load calculations\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eOPERATION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eWhe\u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003en normal utility supplied power is\ninterrupted, the LiteGear Series unit will\nautomatically transfer to emergency mode\nin less than 2-seconds and begin supplying\ninverted, battery-derived pure sine wave\noutput power to the load for 90 minutes\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eThe unit is capable of operating normally on,\nnormally off, switched or dimmed loads\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eA low voltage battery disconnect circuit\nwill prevent \"deep discharge\" damage to\nthe battery\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eThe charging circuit will bring the batteries\nto full recharge within UL time standards\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eA \"brownout\" circuit will automatically\ntransfer the unit to emergency power if the\nutility voltage falls to a pre-determined \"low line\" limit\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eCONSTRUCTION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\u003cli\u003eThe LiteGear enclosure and cover\nare constructed of heavy-duty, steel with\na white powder-coat paint finish.\u003c\/li\u003e\u003c\/ul\u003e\u003cb\u003eCOMPLIANCES\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eUL 924 (Emergency Lighting)\u003c\/li\u003e\n\u003cli\u003eLife Safety Code (NFPA 101)\u003c\/li\u003e\n\u003cli\u003eNational Electrical Code (NFPA 70)\u003c\/li\u003e\n\u003cli\u003eState and Local Code compliant\u003c\/li\u003e\n\u003cli\u003eCEC Title 20 Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eWARRANTY\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eUnit and Electronics: 3 years full (excludes fuses)\u003c\/li\u003e\n\u003cli\u003eelf-Test Model Unit and Electronics:\n5 years full (excludes fuses)\u003c\/li\u003e\n\u003cli\u003eSLA Lead Calcium Battery: 3 years full,\n7 years pro-rata\u003c\/li\u003e\n\u003c\/ul\u003e \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/dual-lite-LG375SI-LG600SI-ordering-information_3380d9ba-c51e-4c9f-b218-46a536f7a9c8.jpg?v=1761765013\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441732247859,"sku":"Dual-Lite-LG375SI","price":2433.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LG375SI-2.jpg?v=1734126869"},{"product_id":"dual-lite-lg600si","title":"Dual-Lite LG600SI LiteGear 600VA\/W Single-Phase Central Lighting Inverter, Surface Wall Mount, With Spectron Self Testing","description":"\u003cb\u003ePRODUCT SPECIFICATIONS\u003cbr\u003eAPPLICATION\u003c\/b\u003e\u003cbr\u003e\u003cul style=\"letter-spacing: normal;\"\u003e\n\u003cli\u003eDesigned for indoor installation in commercial or industrial applications.\u003c\/li\u003e\n\u003cli\u003eEmergency AC power is supplied to lighting fixtures equipped with incandescent, linear fluorescent, compact fluorescent or LED lamps\u003c\/li\u003e\n\u003cli\u003eThe lighting load can be installed at a distance of up to 1,000 feet from the LiteGear central lighting inverter\u003c\/li\u003e\n\u003cli\u003eObserve all required AC conductor sizing requirements\u003c\/li\u003e\n\u003cli\u003eWhen using LED lamps, consider LED in-rush current in load calculations\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eOPERATION\u003c\/b\u003e\u003cbr\u003e\u003cul style=\"letter-spacing: normal;\"\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eWhe\u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003en normal utility supplied power is interrupted, the LiteGear Series unit will automatically transfer to emergency mode in less than 2-seconds and begin supplying inverted, battery-derived pure sine wave output power to the load for 90 minutes\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eThe unit is capable of operating normally on, normally off, switched or dimmed loads\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eA low voltage battery disconnect circuit will prevent \"deep discharge\" damage to the battery\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eThe charging circuit will bring the batteries to full recharge within UL time standards\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eA \"brownout\" circuit will automatically transfer the unit to emergency power if the utility voltage falls to a pre-determined \"low line\" limit\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eCONSTRUCTION\u003c\/b\u003e\u003cbr\u003e\u003cul style=\"letter-spacing: normal;\"\u003e\u003cli\u003eThe LiteGear enclosure and cover are constructed of heavy-duty, steel with a white powder-coat paint finish.\u003c\/li\u003e\u003c\/ul\u003e\u003cb\u003eCOMPLIANCES\u003c\/b\u003e\u003cbr\u003e\u003cul style=\"letter-spacing: normal;\"\u003e\n\u003cli\u003eUL 924 (Emergency Lighting)\u003c\/li\u003e\n\u003cli\u003eLife Safety Code (NFPA 101)\u003c\/li\u003e\n\u003cli\u003eNational Electrical Code (NFPA 70)\u003c\/li\u003e\n\u003cli\u003eState and Local Code compliant\u003c\/li\u003e\n\u003cli\u003eCEC Title 20 Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eWARRANTY\u003c\/b\u003e\u003cbr\u003e\u003cul style=\"letter-spacing: normal;\"\u003e\n\u003cli\u003eUnit and Electronics: 3 years full (excludes fuses)\u003c\/li\u003e\n\u003cli\u003eelf-Test Model Unit and Electronics: 5 years full (excludes fuses)\u003c\/li\u003e\n\u003cli\u003eSLA Lead Calcium Battery: 3 years full, 7 years pro-rata\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/dual-lite-LG375SI-LG600SI-ordering-information_3380d9ba-c51e-4c9f-b218-46a536f7a9c8.jpg?v=1761765013\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441732903219,"sku":"Dual-Lite-LG600SI","price":6391.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LG600SI-2.jpg?v=1734126885"},{"product_id":"dual-lite-lps20-r","title":"Dual-Lite LPS20-R 20W Central Lighting Micro Inverter, Recessed Wall Mount","description":"\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\nDesigned for indoor installation in commercial or industrial applications, LIGHTPOWER™ Series micro inverter systems provide sinusoidal Emergency AC power to lighting fixtures equipped with incandescent, linear fluorescent, compact fluorescent or LED lamps between 20 and 55 watts. The lighting load can be installed at a distance of up to 1,000 feet from the LIGHTPOWER™ micro inverter. Observe all required AC conductor sizing requirements.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\nWhen normal utility supplied power is interrupted, the LIGHTPOWER™ Series unit will automatically transfer to emergency mode in less than 1-second and begin supplying pure sinusoidal AC power to the load for 90 minutes. The unit is capable of operating normally on, normally off, or switched loads. A low voltage battery disconnect circuit will prevent “deep discharge” damage to the battery. AC lockout prevents battery discharge prior to initial unit power-up. The charging circuit will bring the batteries to full recharge within UL time standards. A “brownout” circuit will automatically transfer the unit to emergency power if the utility voltage falls to a predetermined “low line” limit.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eConstruction\u003c\/strong\u003e\u003cbr\u003e\nThe LIGHTPOWER™ enclosure and cover are constructed of heavy-duty, 20 gauge steel with a white powder-coat paint finish.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\nUL 924 (Emergency Lighting)\u003cbr\u003e\nLife Safety Code (NFPA 101)\u003cbr\u003e\nNational Electrical Code (NFPA 70)\u003cbr\u003e\nOSHA, State and Local Code compliant\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\nUnit and Electronics: 3 years full*\u003cbr\u003e\nBatteries: SLA Lead Calcium: 3 years full, 7 years pro-rata\u003cbr\u003e\nNickel Cadmium: 2 years full, 13 years pro-rata\u003cbr\u003e\n* excludes fuses\n\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LPS-ordering-information_e4211a6b-13bd-4952-b3ab-7d3e979df591.jpg?v=1761765151\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441753547059,"sku":"Dual-Lite-LPS20-R","price":889.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LPS20-R-2.jpg?v=1734127383"},{"product_id":"dual-lite-lps20-s","title":"Dual-Lite LPS20-S 20W Central Lighting Micro Inverter, Surface Wall Mount","description":"\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\nDesigned for indoor installation in commercial or industrial applications, LIGHTPOWER™ Series micro inverter systems provide sinusoidal Emergency AC power to lighting fixtures equipped with incandescent, linear fluorescent, compact fluorescent or LED lamps between 20 and 55 watts. The lighting load can be installed at a distance of up to 1,000 feet from the LIGHTPOWER™ micro inverter. Observe all required AC conductor sizing requirements.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\nWhen normal utility supplied power is interrupted, the LIGHTPOWER™ Series unit will automatically transfer to emergency mode in less than 1-second and begin supplying pure sinusoidal AC power to the load for 90 minutes. The unit is capable of operating normally on, normally off, or switched loads. A low voltage battery disconnect circuit will prevent “deep discharge” damage to the battery. AC lockout prevents battery discharge prior to initial unit power-up. The charging circuit will bring the batteries to full recharge within UL time standards. A “brownout” circuit will automatically transfer the unit to emergency power if the utility voltage falls to a predetermined “low line” limit.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eConstruction\u003c\/strong\u003e\u003cbr\u003e\nThe LIGHTPOWER™ enclosure and cover are constructed of heavy-duty, 20 gauge steel with a white powder-coat paint finish.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\nUL 924 (Emergency Lighting)\u003cbr\u003e\nLife Safety Code (NFPA 101)\u003cbr\u003e\nNational Electrical Code (NFPA 70)\u003cbr\u003e\nOSHA, State and Local Code compliant\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\nUnit and Electronics: 3 years full*\u003cbr\u003e\nBatteries: SLA Lead Calcium: 3 years full, 7 years pro-rata\u003cbr\u003e\nNickel Cadmium: 2 years full, 13 years pro-rata\u003cbr\u003e\n* excludes fuses\n\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LPS-ordering-information_e4211a6b-13bd-4952-b3ab-7d3e979df591.jpg?v=1761765151\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441754169651,"sku":"Dual-Lite-LPS20-S","price":789.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LPS20-S-2.jpg?v=1734127402"},{"product_id":"dual-lite-lps20-t","title":"Dual-Lite LPS20-T 20W Central Lighting Micro Inverter, Recessed Ceilig T-Grid Mount","description":"\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\nDesigned for indoor installation in commercial or industrial applications, LIGHTPOWER™ Series micro inverter systems provide sinusoidal Emergency AC power to lighting fixtures equipped with incandescent, linear fluorescent, compact fluorescent or LED lamps between 20 and 55 watts. The lighting load can be installed at a distance of up to 1,000 feet from the LIGHTPOWER™ micro inverter. Observe all required AC conductor sizing requirements.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\nWhen normal utility supplied power is interrupted, the LIGHTPOWER™ Series unit will automatically transfer to emergency mode in less than 1-second and begin supplying pure sinusoidal AC power to the load for 90 minutes. The unit is capable of operating normally on, normally off, or switched loads. A low voltage battery disconnect circuit will prevent “deep discharge” damage to the battery. AC lockout prevents battery discharge prior to initial unit power-up. The charging circuit will bring the batteries to full recharge within UL time standards. A “brownout” circuit will automatically transfer the unit to emergency power if the utility voltage falls to a predetermined “low line” limit.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eConstruction\u003c\/strong\u003e\u003cbr\u003e\nThe LIGHTPOWER™ enclosure and cover are constructed of heavy-duty, 20 gauge steel with a white powder-coat paint finish.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\nUL 924 (Emergency Lighting)\u003cbr\u003e\nLife Safety Code (NFPA 101)\u003cbr\u003e\nNational Electrical Code (NFPA 70)\u003cbr\u003e\nOSHA, State and Local Code compliant\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\nUnit and Electronics: 3 years full*\u003cbr\u003e\nBatteries: SLA Lead Calcium: 3 years full, 7 years pro-rata\u003cbr\u003e\nNickel Cadmium: 2 years full, 13 years pro-rata\u003cbr\u003e\n* excludes fuses\n\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LPS-ordering-information_e4211a6b-13bd-4952-b3ab-7d3e979df591.jpg?v=1761765151\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441754792243,"sku":"Dual-Lite-LPS20-T","price":883.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LPS20-T-2.jpg?v=1734127417"},{"product_id":"dual-lite-lps32-r","title":"Dual-Lite LPS32-R 32W Central Lighting Micro Inverter, Recessed Wall Mount","description":"\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\nDesigned for indoor installation in commercial or industrial applications, LIGHTPOWER™ Series micro inverter systems provide sinusoidal Emergency AC power to lighting fixtures equipped with incandescent, linear fluorescent, compact fluorescent or LED lamps between 20 and 55 watts. The lighting load can be installed at a distance of up to 1,000 feet from the LIGHTPOWER™ micro inverter. Observe all required AC conductor sizing requirements.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\nWhen normal utility supplied power is interrupted, the LIGHTPOWER™ Series unit will automatically transfer to emergency mode in less than 1-second and begin supplying pure sinusoidal AC power to the load for 90 minutes. The unit is capable of operating normally on, normally off, or switched loads. A low voltage battery disconnect circuit will prevent “deep discharge” damage to the battery. AC lockout prevents battery discharge prior to initial unit power-up. The charging circuit will bring the batteries to full recharge within UL time standards. A “brownout” circuit will automatically transfer the unit to emergency power if the utility voltage falls to a predetermined “low line” limit.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eConstruction\u003c\/strong\u003e\u003cbr\u003e\nThe LIGHTPOWER™ enclosure and cover are constructed of heavy-duty, 20 gauge steel with a white powder-coat paint finish.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\nUL 924 (Emergency Lighting)\u003cbr\u003e\nLife Safety Code (NFPA 101)\u003cbr\u003e\nNational Electrical Code (NFPA 70)\u003cbr\u003e\nOSHA, State and Local Code compliant\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\nUnit and Electronics: 3 years full*\u003cbr\u003e\nBatteries: SLA Lead Calcium: 3 years full, 7 years pro-rata\u003cbr\u003e\nNickel Cadmium: 2 years full, 13 years pro-rata\u003cbr\u003e\n* excludes fuses\n\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LPS-ordering-information_e4211a6b-13bd-4952-b3ab-7d3e979df591.jpg?v=1761765151\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441755480371,"sku":"Dual-Lite-LPS32-R","price":802.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LPS32-R-2.jpg?v=1734127433"},{"product_id":"dual-lite-lps32-s","title":"Dual-Lite LPS32-S 32W Central Lighting Micro Inverter, Surface Wall Mount","description":"\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\nDesigned for indoor installation in commercial or industrial applications, LIGHTPOWER™ Series micro inverter systems provide sinusoidal Emergency AC power to lighting fixtures equipped with incandescent, linear fluorescent, compact fluorescent or LED lamps between 20 and 55 watts. The lighting load can be installed at a distance of up to 1,000 feet from the LIGHTPOWER™ micro inverter. Observe all required AC conductor sizing requirements.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\nWhen normal utility supplied power is interrupted, the LIGHTPOWER™ Series unit will automatically transfer to emergency mode in less than 1-second and begin supplying pure sinusoidal AC power to the load for 90 minutes. The unit is capable of operating normally on, normally off, or switched loads. A low voltage battery disconnect circuit will prevent “deep discharge” damage to the battery. AC lockout prevents battery discharge prior to initial unit power-up. The charging circuit will bring the batteries to full recharge within UL time standards. A “brownout” circuit will automatically transfer the unit to emergency power if the utility voltage falls to a predetermined “low line” limit.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eConstruction\u003c\/strong\u003e\u003cbr\u003e\nThe LIGHTPOWER™ enclosure and cover are constructed of heavy-duty, 20 gauge steel with a white powder-coat paint finish.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\nUL 924 (Emergency Lighting)\u003cbr\u003e\nLife Safety Code (NFPA 101)\u003cbr\u003e\nNational Electrical Code (NFPA 70)\u003cbr\u003e\nOSHA, State and Local Code compliant\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\nUnit and Electronics: 3 years full*\u003cbr\u003e\nBatteries: SLA Lead Calcium: 3 years full, 7 years pro-rata\u003cbr\u003e\nNickel Cadmium: 2 years full, 13 years pro-rata\u003cbr\u003e\n* excludes fuses\n\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LPS-ordering-information_e4211a6b-13bd-4952-b3ab-7d3e979df591.jpg?v=1761765151\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441756102963,"sku":"Dual-Lite-LPS32-S","price":560.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LPS32-S-2.jpg?v=1734127450"},{"product_id":"dual-lite-lps32-t","title":"Dual-Lite LPS32-T 32W Central Lighting Micro Inverter, Recessed Ceilig T-Grid Mount","description":"\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\nDesigned for indoor installation in commercial or industrial applications, LIGHTPOWER™ Series micro inverter systems provide sinusoidal Emergency AC power to lighting fixtures equipped with incandescent, linear fluorescent, compact fluorescent or LED lamps between 20 and 55 watts. The lighting load can be installed at a distance of up to 1,000 feet from the LIGHTPOWER™ micro inverter. Observe all required AC conductor sizing requirements.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\nWhen normal utility supplied power is interrupted, the LIGHTPOWER™ Series unit will automatically transfer to emergency mode in less than 1-second and begin supplying pure sinusoidal AC power to the load for 90 minutes. The unit is capable of operating normally on, normally off, or switched loads. A low voltage battery disconnect circuit will prevent “deep discharge” damage to the battery. AC lockout prevents battery discharge prior to initial unit power-up. The charging circuit will bring the batteries to full recharge within UL time standards. A “brownout” circuit will automatically transfer the unit to emergency power if the utility voltage falls to a predetermined “low line” limit.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eConstruction\u003c\/strong\u003e\u003cbr\u003e\nThe LIGHTPOWER™ enclosure and cover are constructed of heavy-duty, 20 gauge steel with a white powder-coat paint finish.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\nUL 924 (Emergency Lighting)\u003cbr\u003e\nLife Safety Code (NFPA 101)\u003cbr\u003e\nNational Electrical Code (NFPA 70)\u003cbr\u003e\nOSHA, State and Local Code compliant\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\nUnit and Electronics: 3 years full*\u003cbr\u003e\nBatteries: SLA Lead Calcium: 3 years full, 7 years pro-rata\u003cbr\u003e\nNickel Cadmium: 2 years full, 13 years pro-rata\u003cbr\u003e\n* excludes fuses\n\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LPS-ordering-information_e4211a6b-13bd-4952-b3ab-7d3e979df591.jpg?v=1761765151\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441756725555,"sku":"Dual-Lite-LPS32-T","price":666.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LPS32-T-2.jpg?v=1734127466"},{"product_id":"dual-lite-lps35-r","title":"Dual-Lite LPS35-R 35W Central Lighting Micro Inverter, Recessed Wall Mount","description":"\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\nDesigned for indoor installation in commercial or industrial applications, LIGHTPOWER™ Series micro inverter systems provide sinusoidal Emergency AC power to lighting fixtures equipped with incandescent, linear fluorescent, compact fluorescent or LED lamps between 20 and 55 watts. The lighting load can be installed at a distance of up to 1,000 feet from the LIGHTPOWER™ micro inverter. Observe all required AC conductor sizing requirements.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\nWhen normal utility supplied power is interrupted, the LIGHTPOWER™ Series unit will automatically transfer to emergency mode in less than 1-second and begin supplying pure sinusoidal AC power to the load for 90 minutes. The unit is capable of operating normally on, normally off, or switched loads. A low voltage battery disconnect circuit will prevent “deep discharge” damage to the battery. AC lockout prevents battery discharge prior to initial unit power-up. The charging circuit will bring the batteries to full recharge within UL time standards. A “brownout” circuit will automatically transfer the unit to emergency power if the utility voltage falls to a predetermined “low line” limit.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eConstruction\u003c\/strong\u003e\u003cbr\u003e\nThe LIGHTPOWER™ enclosure and cover are constructed of heavy-duty, 20 gauge steel with a white powder-coat paint finish.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\nUL 924 (Emergency Lighting)\u003cbr\u003e\nLife Safety Code (NFPA 101)\u003cbr\u003e\nNational Electrical Code (NFPA 70)\u003cbr\u003e\nOSHA, State and Local Code compliant\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\nUnit and Electronics: 3 years full*\u003cbr\u003e\nBatteries: SLA Lead Calcium: 3 years full, 7 years pro-rata\u003cbr\u003e\nNickel Cadmium: 2 years full, 13 years pro-rata\u003cbr\u003e\n* excludes fuses\n\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LPS-ordering-information_e4211a6b-13bd-4952-b3ab-7d3e979df591.jpg?v=1761765151\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441757348147,"sku":"Dual-Lite-LPS35-R","price":1094.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LPS35-R-2.jpg?v=1734127482"},{"product_id":"dual-lite-lps35-s","title":"Dual-Lite LPS35-S 35W Central Lighting Micro Inverter, Surface Wall Mount","description":"\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\nDesigned for indoor installation in commercial or industrial applications, LIGHTPOWER™ Series micro inverter systems provide sinusoidal Emergency AC power to lighting fixtures equipped with incandescent, linear fluorescent, compact fluorescent or LED lamps between 20 and 55 watts. The lighting load can be installed at a distance of up to 1,000 feet from the LIGHTPOWER™ micro inverter. Observe all required AC conductor sizing requirements.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\nWhen normal utility supplied power is interrupted, the LIGHTPOWER™ Series unit will automatically transfer to emergency mode in less than 1-second and begin supplying pure sinusoidal AC power to the load for 90 minutes. The unit is capable of operating normally on, normally off, or switched loads. A low voltage battery disconnect circuit will prevent “deep discharge” damage to the battery. AC lockout prevents battery discharge prior to initial unit power-up. The charging circuit will bring the batteries to full recharge within UL time standards. A “brownout” circuit will automatically transfer the unit to emergency power if the utility voltage falls to a predetermined “low line” limit.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eConstruction\u003c\/strong\u003e\u003cbr\u003e\nThe LIGHTPOWER™ enclosure and cover are constructed of heavy-duty, 20 gauge steel with a white powder-coat paint finish.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\nUL 924 (Emergency Lighting)\u003cbr\u003e\nLife Safety Code (NFPA 101)\u003cbr\u003e\nNational Electrical Code (NFPA 70)\u003cbr\u003e\nOSHA, State and Local Code compliant\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\nUnit and Electronics: 3 years full*\u003cbr\u003e\nBatteries: SLA Lead Calcium: 3 years full, 7 years pro-rata\u003cbr\u003e\nNickel Cadmium: 2 years full, 13 years pro-rata\u003cbr\u003e\n* excludes fuses\n\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LPS-ordering-information_e4211a6b-13bd-4952-b3ab-7d3e979df591.jpg?v=1761765151\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441757479219,"sku":"Dual-Lite-LPS35-S","price":1032.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LPS35-S-2.jpg?v=1734127498"},{"product_id":"dual-lite-lps35-t","title":"Dual-Lite LPS35-T 35W Central Lighting Micro Inverter, Recessed Ceilig T-Grid Mount","description":"\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\nDesigned for indoor installation in commercial or industrial applications, LIGHTPOWER™ Series micro inverter systems provide sinusoidal Emergency AC power to lighting fixtures equipped with incandescent, linear fluorescent, compact fluorescent or LED lamps between 20 and 55 watts. The lighting load can be installed at a distance of up to 1,000 feet from the LIGHTPOWER™ micro inverter. Observe all required AC conductor sizing requirements.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\nWhen normal utility supplied power is interrupted, the LIGHTPOWER™ Series unit will automatically transfer to emergency mode in less than 1-second and begin supplying pure sinusoidal AC power to the load for 90 minutes. The unit is capable of operating normally on, normally off, or switched loads. A low voltage battery disconnect circuit will prevent “deep discharge” damage to the battery. AC lockout prevents battery discharge prior to initial unit power-up. The charging circuit will bring the batteries to full recharge within UL time standards. A “brownout” circuit will automatically transfer the unit to emergency power if the utility voltage falls to a predetermined “low line” limit.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eConstruction\u003c\/strong\u003e\u003cbr\u003e\nThe LIGHTPOWER™ enclosure and cover are constructed of heavy-duty, 20 gauge steel with a white powder-coat paint finish.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\nUL 924 (Emergency Lighting)\u003cbr\u003e\nLife Safety Code (NFPA 101)\u003cbr\u003e\nNational Electrical Code (NFPA 70)\u003cbr\u003e\nOSHA, State and Local Code compliant\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\nUnit and Electronics: 3 years full*\u003cbr\u003e\nBatteries: SLA Lead Calcium: 3 years full, 7 years pro-rata\u003cbr\u003e\nNickel Cadmium: 2 years full, 13 years pro-rata\u003cbr\u003e\n* excludes fuses\n\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LPS-ordering-information_e4211a6b-13bd-4952-b3ab-7d3e979df591.jpg?v=1761765151\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441758101811,"sku":"Dual-Lite-LPS35-T","price":881.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LPS35-T-2.jpg?v=1734127516"},{"product_id":"dual-lite-lps55-r","title":"Dual-Lite LPS55-R 55W Central Lighting Micro Inverter, Recessed Wall Mount","description":"\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\nDesigned for indoor installation in commercial or industrial applications, LIGHTPOWER™ Series micro inverter systems provide sinusoidal Emergency AC power to lighting fixtures equipped with incandescent, linear fluorescent, compact fluorescent or LED lamps between 20 and 55 watts. The lighting load can be installed at a distance of up to 1,000 feet from the LIGHTPOWER™ micro inverter. Observe all required AC conductor sizing requirements.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\nWhen normal utility supplied power is interrupted, the LIGHTPOWER™ Series unit will automatically transfer to emergency mode in less than 1-second and begin supplying pure sinusoidal AC power to the load for 90 minutes. The unit is capable of operating normally on, normally off, or switched loads. A low voltage battery disconnect circuit will prevent “deep discharge” damage to the battery. AC lockout prevents battery discharge prior to initial unit power-up. The charging circuit will bring the batteries to full recharge within UL time standards. A “brownout” circuit will automatically transfer the unit to emergency power if the utility voltage falls to a predetermined “low line” limit.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eConstruction\u003c\/strong\u003e\u003cbr\u003e\nThe LIGHTPOWER™ enclosure and cover are constructed of heavy-duty, 20 gauge steel with a white powder-coat paint finish.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\nUL 924 (Emergency Lighting)\u003cbr\u003e\nLife Safety Code (NFPA 101)\u003cbr\u003e\nNational Electrical Code (NFPA 70)\u003cbr\u003e\nOSHA, State and Local Code compliant\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\nUnit and Electronics: 3 years full*\u003cbr\u003e\nBatteries: SLA Lead Calcium: 3 years full, 7 years pro-rata\u003cbr\u003e\nNickel Cadmium: 2 years full, 13 years pro-rata\u003cbr\u003e\n* excludes fuses\n\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LPS-ordering-information_e4211a6b-13bd-4952-b3ab-7d3e979df591.jpg?v=1761765151\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441758757171,"sku":"Dual-Lite-LPS55-R","price":939.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LPS55-R-2.jpg?v=1734127531"},{"product_id":"dual-lite-lps55-s","title":"Dual-Lite LPS55-S 55W Central Lighting Micro Inverter, Surface Wall Mount","description":"\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\nDesigned for indoor installation in commercial or industrial applications, LIGHTPOWER™ Series micro inverter systems provide sinusoidal Emergency AC power to lighting fixtures equipped with incandescent, linear fluorescent, compact fluorescent or LED lamps between 20 and 55 watts. The lighting load can be installed at a distance of up to 1,000 feet from the LIGHTPOWER™ micro inverter. Observe all required AC conductor sizing requirements.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\nWhen normal utility supplied power is interrupted, the LIGHTPOWER™ Series unit will automatically transfer to emergency mode in less than 1-second and begin supplying pure sinusoidal AC power to the load for 90 minutes. The unit is capable of operating normally on, normally off, or switched loads. A low voltage battery disconnect circuit will prevent “deep discharge” damage to the battery. AC lockout prevents battery discharge prior to initial unit power-up. The charging circuit will bring the batteries to full recharge within UL time standards. A “brownout” circuit will automatically transfer the unit to emergency power if the utility voltage falls to a predetermined “low line” limit.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eConstruction\u003c\/strong\u003e\u003cbr\u003e\nThe LIGHTPOWER™ enclosure and cover are constructed of heavy-duty, 20 gauge steel with a white powder-coat paint finish.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\nUL 924 (Emergency Lighting)\u003cbr\u003e\nLife Safety Code (NFPA 101)\u003cbr\u003e\nNational Electrical Code (NFPA 70)\u003cbr\u003e\nOSHA, State and Local Code compliant\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\nUnit and Electronics: 3 years full*\u003cbr\u003e\nBatteries: SLA Lead Calcium: 3 years full, 7 years pro-rata\u003cbr\u003e\nNickel Cadmium: 2 years full, 13 years pro-rata\u003cbr\u003e\n* excludes fuses\n\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LPS-ordering-information_e4211a6b-13bd-4952-b3ab-7d3e979df591.jpg?v=1761765151\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441759412531,"sku":"Dual-Lite-LPS55-S","price":748.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LPS55-S-2.jpg?v=1734127548"},{"product_id":"dual-lite-lps55-t","title":"Dual-Lite LPS55-T 55W Central Lighting Micro Inverter, Recessed Ceilig T-Grid Mount","description":"\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\nDesigned for indoor installation in commercial or industrial applications, LIGHTPOWER™ Series micro inverter systems provide sinusoidal Emergency AC power to lighting fixtures equipped with incandescent, linear fluorescent, compact fluorescent or LED lamps between 20 and 55 watts. The lighting load can be installed at a distance of up to 1,000 feet from the LIGHTPOWER™ micro inverter. Observe all required AC conductor sizing requirements.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\nWhen normal utility supplied power is interrupted, the LIGHTPOWER™ Series unit will automatically transfer to emergency mode in less than 1-second and begin supplying pure sinusoidal AC power to the load for 90 minutes. The unit is capable of operating normally on, normally off, or switched loads. A low voltage battery disconnect circuit will prevent “deep discharge” damage to the battery. AC lockout prevents battery discharge prior to initial unit power-up. The charging circuit will bring the batteries to full recharge within UL time standards. A “brownout” circuit will automatically transfer the unit to emergency power if the utility voltage falls to a predetermined “low line” limit.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eConstruction\u003c\/strong\u003e\u003cbr\u003e\nThe LIGHTPOWER™ enclosure and cover are constructed of heavy-duty, 20 gauge steel with a white powder-coat paint finish.\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\nUL 924 (Emergency Lighting)\u003cbr\u003e\nLife Safety Code (NFPA 101)\u003cbr\u003e\nNational Electrical Code (NFPA 70)\u003cbr\u003e\nOSHA, State and Local Code compliant\u003cbr\u003e\n\u003cstrong\u003e\u003cbr\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\nUnit and Electronics: 3 years full*\u003cbr\u003e\nBatteries: SLA Lead Calcium: 3 years full, 7 years pro-rata\u003cbr\u003e\nNickel Cadmium: 2 years full, 13 years pro-rata\u003cbr\u003e\n* excludes fuses\n\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/LPS-ordering-information_e4211a6b-13bd-4952-b3ab-7d3e979df591.jpg?v=1761765151\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441760198963,"sku":"Dual-Lite-LPS55-T","price":706.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LPS55-T-2.jpg?v=1734127565"},{"product_id":"dual-lite-d208-48s120-a2002ibs","title":"Dual Lite D208-48S120-A2002-IBS Single-Phase Central Lighting Inverter, 208VAC Input, 4.8KVA, 10-year VRLA Lead-Calcium, 120VAC  Output Voltage, 120VAC, 20A Output Circuit Breaker Rating, 2 Output Circuit Breakers, Internal Maintenance Bypass Switch","description":"\u003cb\u003ePRODUCT FAMILY SPECIFICATIONS\u003cbr\u003e\u003c\/b\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cb\u003eAPPLICATION\u003c\/b\u003e\u003cbr\u003e\n\u003cul\u003e\n \u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eIndoor Commercial\u003c\/span\u003e\n\u003c\/li\u003e\n \u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003eIndoor Industrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/span\u003e\u003cb\u003eOPERATION\u003c\/b\u003e\u003cbr\u003e\n\u003cul\u003e\n \u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eAutomatic, programmable self-diagnostic \u003c\/span\u003eoperation\u003c\/li\u003e\n \u003cli\u003eWhen normal utility-supplied power is present, the LSN model central lighting inverter provides load-side line conditioning with \"brownout\" protection, and charges the system batteries when required.\u003c\/li\u003e\n \u003cli\u003eWhen utility-supplied power is interrupted, or the voltage varies from predetermined limits, the system will automatically and instantaneously transfer to emergency mode without interruption to connected loads.\u003c\/li\u003e\n \u003cli\u003eDC battery-derived emergency power is inverted to AC power and supplied in a pure sine wave output form for 90 minutes (standard run time).\u003c\/li\u003e\n \u003cli\u003eA low voltage battery disconnect circuit prevents \"deep discharge\" damage to the batteries during prolonged power outages. When normal power is restored the system will automatically restart, providing power to connected loads and recharging the batteries.\u003c\/li\u003e\n \u003cli\u003eThe charging circuit will bring the batteries to full recharge within UL time standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n \u003cspan style=\"background-color: initial;\"\u003e\u003cb\u003eCONSTRUCTION\u003c\/b\u003e\u003cbr\u003e\n \u003cul\u003e\n  \u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eSteel Cabinet\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003eLight grey paint finish\u003c\/li\u003e\n  \u003cli\u003eLocking cabinetry and password-protected user interface for security\u003c\/li\u003e\n  \u003cli\u003eLouvers at front and top of cabinet allow venting.\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cb\u003eINSTALLATION\u003c\/b\u003e\u003cbr\u003e\n\u003cul\u003e\n \u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eInput power entry point is from the \u003c\/span\u003ecabinet top.\u003c\/li\u003e\n \u003cli\u003eBottom channels for lifting straps\u003c\/li\u003e\n \u003cli\u003eWall brackets for anchoring.\u003c\/li\u003e\n \u003cli\u003eServicing is accessible from cabinet front.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003eCERTIFICATIONS\/COMPLIANCES\u003c\/b\u003e\u003cbr\u003e\n\u003cul\u003e\n \u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eUL 924 Listed, Emergency Lighting and \u003c\/span\u003ePower Equipment (standard 90 minute run time), type S battery, all voltages except 347V\u003c\/li\u003e\n \u003cli\u003eUL \u0026amp; CUL 1778 Listed, Uninterruptible Power Supply Equipment (alternate run times; type G batteries; 347V input\/output)\u003c\/li\u003e\n \u003cli\u003eANSI C62.41: ANSI C62.45 (Cat. A \u0026amp; B)\u003c\/li\u003e\n \u003cli\u003eFCC class A\u003c\/li\u003e\n \u003cli\u003eNational Electrical Code (NFPA 70)\u003c\/li\u003e\n \u003cli\u003eLife Safety Code (NFPA 101)\u003c\/li\u003e\n \u003cli\u003eNFPA 111 (Stored Emergency Power Supply Systems - SEPSS)\u003c\/li\u003e\n \u003cli\u003eNEMA Type 1 Cabinetry\u003c\/li\u003e\n \u003cli\u003eOSHA, state and local codes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n \u003cspan style=\"background-color: initial;\"\u003e\u003cb\u003eWARRANTY\u003c\/b\u003e\u003cbr\u003e\n \u003cul\u003e\n  \u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTwo years full on all components from date \u003c\/span\u003eof shipment when a Factory Start-Up is performed; one year full when a Factory Start-Up is not performed.\u003c\/li\u003e\n  \u003cli\u003eBatteries are covered under a separate warranty:\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003cspan\u003e\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/dual-lite-LSN-D-Series-battery-warranty-information_ff710a2a-9e21-4320-9b55-8fe88fd66b17.jpg?v=1761762803\" style=\"background-color: initial; letter-spacing: 0px;\"\u003e\u003cbr\u003e\n \u003cul\u003e\n  \u003cli\u003eBatteries must be connected to an energized charging circuit within 90 days from date of shipment or warranty is void.\u003c\/li\u003e\n  \u003cli\u003eStart-Up must be performed by an Authorized Service Center within 6 months of inverter shipment and will increase the inverter warranty to 2 years. Order quantity of 1 per system. Systems powered up by others are done so at their own risk.\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003cbr\u003e\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/dual-lite-LSN-D-Series-ordering-information_b6201431-e64a-47ef-910f-0665230e94f9.jpg?v=1761762805\"\u003e\n\u003c\/div\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":50248590262579,"sku":"Dual-Lite-D208-48S120-A2002IBS","price":53744.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-D208-48S120-A2002IBS-2.jpg?v=1734123970"},{"product_id":"dual-lite-dls-28","title":"Dual Lite DLS-2100-120-A-20-10U 2100W Single-Phase Central Lighting Inverter, 120V Input Voltage, Normally On, 120V Output Voltage, 20 Amp, 10 Circuit Breakers, Unmonitored","description":"\u003cp\u003e\n \u003cstrong\u003eApplication\u003c\/strong\u003e\u003cbr\u003e\n Designed for indoor installation in commercial or industrial applications.\u003cbr\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\n When normal utility-supplied power is present, the Synchron central lighting inverter allows utility power to pass through to the connected load and charges the system batteries as required. When utilitysupplied power is interrupted, the system will automatically and instantaneously transfer to emergency mode without interruption to connected loads. DC battery-derived emergency power is inverted to AC power and supplied in a pure sine wave output form for 90 minutes (standard run time).\u003cbr\u003e\n A low voltage battery disconnect circuit prevents ?deep discharge? damage to the batteries during prolonged power outages. When normal power is restored the system will automatically restart, providing power to connected loads and recharging the batteries. The charging circuit will bring the batteries to full recharge within UL time standards.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003e\n The Synchron cabinet is constructed of NEMA 1 rated, painted steel.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eInstallation\u003c\/strong\u003e\u003cbr\u003e\n Input power entry point is from the cabinet top. Unit supplied with wall brackets for anchoring and features front service entry.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCompliances\u003c\/strong\u003e\u003cbr\u003e\n UL 924 Listed, Emergency Lighting and Power Equipment\u003cbr\u003e\n (standard 90 minute run time)\u003cbr\u003e\n National Electrical Code (NFPA 70)\u003cbr\u003e\n Life Safety Code (NFPA 101)\u003cbr\u003e\n OSHA, state and local codes\u003cbr\u003e\n Made in U.S.A.\u003cbr\u003e\n Factory Startup\u003cbr\u003e\n Use accessory number FSS when ordering\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e\n Two years full on all components from date of shipment when a Factory Start-Up is ordered; one year full when a Factory Start-Up is not ordered.\u003cbr\u003e\n One year full, 9 years pro-rata for batteries.\n\u003c\/p\u003e\n\u003cb\u003eORDERING INFORMATION\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/DLS-ordering-information_1a15086f-938a-4865-9908-9854ef49f193.jpg?v=1761762869\"\u003e\u003c\/b\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":50248593408307,"sku":"Dual-Lite-DLS-28","price":16980.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-DLS-28-2.jpg?v=1734123987"},{"product_id":"dual-lite-lg375s","title":"Dual-Lite LG375S LiteGear 375VA\/W Single-Phase Central Lighting Inverter, Surface Wall Mount","description":"\u003cb\u003ePRODUCT SPECIFICATIONS\u003cbr\u003eAPPLICATION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eDesigned for indoor installation in\ncommercial or industrial applications.\u003c\/li\u003e\n\u003cli\u003eEmergency AC power is supplied to lighting\nfixtures equipped with incandescent,\nlinear fluorescent, compact fluorescent\nor LED lamps\u003c\/li\u003e\n\u003cli\u003eThe lighting load can be installed at a\ndistance of up to 1,000 feet from the\nLiteGear central lighting inverter\u003c\/li\u003e\n\u003cli\u003eObserve all required AC conductor\nsizing requirements\u003c\/li\u003e\n\u003cli\u003eWhen using LED lamps, consider LED in-rush\ncurrent in load calculations\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eOPERATION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eWhe\u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003en normal utility supplied power is\ninterrupted, the LiteGear Series unit will\nautomatically transfer to emergency mode\nin less than 2-seconds and begin supplying\ninverted, battery-derived pure sine wave\noutput power to the load for 90 minutes\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eThe unit is capable of operating normally on,\nnormally off, switched or dimmed loads\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eA low voltage battery disconnect circuit\nwill prevent \"deep discharge\" damage to\nthe battery\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eThe charging circuit will bring the batteries\nto full recharge within UL time standards\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eA \"brownout\" circuit will automatically\ntransfer the unit to emergency power if the\nutility voltage falls to a pre-determined \"low line\" limit\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eCONSTRUCTION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\u003cli\u003eThe LiteGear enclosure and cover\nare constructed of heavy-duty, steel with\na white powder-coat paint finish.\u003c\/li\u003e\u003c\/ul\u003e\u003cb\u003eCOMPLIANCES\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eUL 924 (Emergency Lighting)\u003c\/li\u003e\n\u003cli\u003eLife Safety Code (NFPA 101)\u003c\/li\u003e\n\u003cli\u003eNational Electrical Code (NFPA 70)\u003c\/li\u003e\n\u003cli\u003eState and Local Code compliant\u003c\/li\u003e\n\u003cli\u003eCEC Title 20 Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eWARRANTY\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eUnit and Electronics: 3 years full (excludes fuses)\u003c\/li\u003e\n\u003cli\u003eelf-Test Model Unit and Electronics:\n5 years full (excludes fuses)\u003c\/li\u003e\n\u003cli\u003eSLA Lead Calcium Battery: 3 years full,\n7 years pro-rata\u003c\/li\u003e\n\u003c\/ul\u003e \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/dual-lite-LG375SI-LG600SI-ordering-information_3380d9ba-c51e-4c9f-b218-46a536f7a9c8.jpg?v=1761765013\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":50248983576883,"sku":"Dual-Lite-LG375S","price":4137.01,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-LG375S-2.jpg?v=1734126849"}],"url":"https:\/\/electricbargainstores.com\/collections\/dual-lite-central-lighting-inverters.oembed?page=2","provider":"Electric Bargain Store","version":"1.0","type":"link"}