{"title":"Juno Aculux Recessed Lighting IC408LPSQ Low Profile 3-1\/4 inch LED Housings","description":"","products":[{"product_id":"juno-ax3sq-lpa-8731","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 12D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 12 Degree Spot, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462206677299,"sku":"Juno-AX3SQ-LPA-8731","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8731-2.jpg?v=1689638606"},{"product_id":"juno-ax3sq-lpa-8733","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 12D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462207037747,"sku":"Juno-AX3SQ-LPA-8733","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8733-2_db9817ee-7c01-4c37-8698-c462d59f7bec.jpg?v=1689638626"},{"product_id":"juno-ax3sq-lpa-8734","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 12D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462207201587,"sku":"Juno-AX3SQ-LPA-8734","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8734-2.jpg?v=1689638636"},{"product_id":"juno-ax3sq-lpa-8737","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 12D EZ1 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 12 Degree Spot, eldoLED 0-10V, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462208807219,"sku":"Juno-AX3SQ-LPA-8737","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8737-2_4f62b0d2-8367-40d8-9979-e3161a088e3e.jpg?v=1689638675"},{"product_id":"juno-ax3sq-lpa-8739","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 12D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462209626419,"sku":"Juno-AX3SQ-LPA-8739","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8739-2_bede71c5-3a12-4228-a201-f26430987a95.jpg?v=1689638700"},{"product_id":"juno-ax3sq-lpa-8740","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 24D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 24 Degree Narrow Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462209790259,"sku":"Juno-AX3SQ-LPA-8740","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8740-2_8d7aa2d6-6f45-4b62-9ae0-0dbcce3e234d.jpg?v=1689638710"},{"product_id":"juno-ax3sq-lpa-8741","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 24D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462209855795,"sku":"Juno-AX3SQ-LPA-8741","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8741-2.jpg?v=1689638722"},{"product_id":"juno-ax3sq-lpa-8742","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 24D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462210019635,"sku":"Juno-AX3SQ-LPA-8742","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8742-2.jpg?v=1689638732"},{"product_id":"juno-ax3sq-lpa-8745","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 24D EZ1 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 24 Degree Narrow Flood, eldoLED 0-10V, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462210707763,"sku":"Juno-AX3SQ-LPA-8745","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8745-2.jpg?v=1689638764"},{"product_id":"juno-ax3sq-lpa-8747","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 24D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462211166515,"sku":"Juno-AX3SQ-LPA-8747","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8747-2.jpg?v=1689638784"},{"product_id":"juno-ax3sq-lpa-8748","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 35D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 35 Degree Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462211461427,"sku":"Juno-AX3SQ-LPA-8748","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8748-2_6d181dff-d10b-4345-abce-de1c038770fa.jpg?v=1689638794"},{"product_id":"juno-ax3sq-lpa-8749","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 35D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462215983411,"sku":"Juno-AX3SQ-LPA-8749","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8749-2.jpg?v=1689638804"},{"product_id":"juno-ax3sq-lpa-8750","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 35D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462218408243,"sku":"Juno-AX3SQ-LPA-8750","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8750-2_c7b0bc83-7419-45c7-8f03-c505b2769911.jpg?v=1689638814"},{"product_id":"juno-ax3sq-lpa-8753","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 35D EZ1 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 35 Degree Flood, eldoLED 0-10V, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462221259059,"sku":"Juno-AX3SQ-LPA-8753","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8753-2_4482b536-39d8-42cc-ac1d-b9cacd45ad81.jpg?v=1689638846"},{"product_id":"juno-ax3sq-lpa-8755","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 35D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462221488435,"sku":"Juno-AX3SQ-LPA-8755","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8755-2.jpg?v=1689638866"},{"product_id":"juno-ax3sq-lpa-8756","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 50D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 50 Degree Wide Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462221914419,"sku":"Juno-AX3SQ-LPA-8756","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8756-2.jpg?v=1689638877"},{"product_id":"juno-ax3sq-lpa-8757","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 50D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462222537011,"sku":"Juno-AX3SQ-LPA-8757","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8757-2_75f55c79-c98d-46f1-a30b-3deb445317eb.jpg?v=1689638887"},{"product_id":"juno-ax3sq-lpa-8758","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 50D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462222733619,"sku":"Juno-AX3SQ-LPA-8758","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8758-2_f08a298f-46eb-4f9e-ae4f-88239b88a426.jpg?v=1689638898"},{"product_id":"juno-ax3sq-lpa-8761","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 50D EZ1 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 50 Degree Wide Flood, eldoLED 0-10V, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462225256755,"sku":"Juno-AX3SQ-LPA-8761","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8761-2_b8e78753-7e9b-4be9-a8a8-78a983923668.jpg?v=1689638928"},{"product_id":"juno-ax3sq-lpa-8763","title":"Juno Aculux AX3SQ LPA 08LM 27K 80CRI 50D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 80 CRI, 50 Degree Wide Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462226239795,"sku":"Juno-AX3SQ-LPA-8763","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8763-2_28742c0e-2bea-44b1-8920-91b158ad76c6.jpg?v=1689638947"},{"product_id":"juno-ax3sq-lpa-8764","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 12D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 12 Degree Spot, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462226665779,"sku":"Juno-AX3SQ-LPA-8764","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8764-2.jpg?v=1689638957"},{"product_id":"juno-ax3sq-lpa-8765","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 12D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462235611443,"sku":"Juno-AX3SQ-LPA-8765","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8765-2.jpg?v=1689638967"},{"product_id":"juno-ax3sq-lpa-8766","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 12D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462238527795,"sku":"Juno-AX3SQ-LPA-8766","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8766-2_851696a2-3f97-433f-9763-af29ae2163d5.jpg?v=1689638977"},{"product_id":"juno-ax3sq-lpa-8769","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 12D EZ1 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 12 Degree Spot, eldoLED 0-10V, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462239019315,"sku":"Juno-AX3SQ-LPA-8769","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8769-2_41f134f5-fa75-47d5-bf79-fa7dfc85b1c0.jpg?v=1689639007"},{"product_id":"juno-ax3sq-lpa-8771","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 12D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462239445299,"sku":"Juno-AX3SQ-LPA-8771","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8771-2_9471869f-0722-4a00-b41c-214357569cb5.jpg?v=1689639028"},{"product_id":"juno-ax3sq-lpa-8772","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 24D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 24 Degree Narrow Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462239936819,"sku":"Juno-AX3SQ-LPA-8772","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8772-2_4b1ad98b-fcc4-4083-9d66-9196d1e2b9bb.jpg?v=1689639038"},{"product_id":"juno-ax3sq-lpa-8774","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 24D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462241280307,"sku":"Juno-AX3SQ-LPA-8774","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8774-2_0221506e-73e3-4f5f-a15b-8fc4a99c783e.jpg?v=1689639057"},{"product_id":"juno-ax3sq-lpa-8775","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 24D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462241607987,"sku":"Juno-AX3SQ-LPA-8775","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8775-2_b75ec6c6-135a-4f85-a53f-4f190a1c9d9d.jpg?v=1689639067"},{"product_id":"juno-ax3sq-lpa-8778","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 24D EZ1 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 24 Degree Narrow Flood, eldoLED 0-10V, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462246129971,"sku":"Juno-AX3SQ-LPA-8778","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8778-2_b775ad46-ab46-403d-ad6b-4fb57baccd9c.jpg?v=1689639098"},{"product_id":"juno-ax3sq-lpa-8780","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 24D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462247506227,"sku":"Juno-AX3SQ-LPA-8780","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8780-2_4949d14d-7167-4e47-9625-3ec71597b1a4.jpg?v=1689639117"},{"product_id":"juno-ax3sq-lpa-8781","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 35D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 35 Degree Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462248227123,"sku":"Juno-AX3SQ-LPA-8781","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8781-2.jpg?v=1689639127"},{"product_id":"juno-ax3sq-lpa-8782","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 35D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462248358195,"sku":"Juno-AX3SQ-LPA-8782","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8782-2_ecc07fc2-8072-41ea-8560-d5e5ab2dbfdf.jpg?v=1689639136"},{"product_id":"juno-ax3sq-lpa-8783","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 35D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462248587571,"sku":"Juno-AX3SQ-LPA-8783","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8783-2.jpg?v=1689639147"},{"product_id":"juno-ax3sq-lpa-8786","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 35D EZ1 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 35 Degree Flood, eldoLED 0-10V, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462249242931,"sku":"Juno-AX3SQ-LPA-8786","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8786-2_895ddc32-91d4-4c6a-8b5f-5a32c5b457eb.jpg?v=1689639177"},{"product_id":"juno-ax3sq-lpa-8788","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 35D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462249963827,"sku":"Juno-AX3SQ-LPA-8788","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8788-2_26560522-9fd0-4f5b-88de-12c6e22ae433.jpg?v=1689639198"},{"product_id":"juno-ax3sq-lpa-8789","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 50D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 50 Degree Wide Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462250193203,"sku":"Juno-AX3SQ-LPA-8789","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8789-2_cee54116-75f7-4442-9d16-63510919fa32.jpg?v=1689639207"},{"product_id":"juno-ax3sq-lpa-8790","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 50D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462250357043,"sku":"Juno-AX3SQ-LPA-8790","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8790-2.jpg?v=1689639217"},{"product_id":"juno-ax3sq-lpa-8791","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 50D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462251602227,"sku":"Juno-AX3SQ-LPA-8791","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8791-2_fa0dd01e-cf58-424f-a821-07680ddbd4a0.jpg?v=1689639227"},{"product_id":"juno-ax3sq-lpa-8794","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 50D EZ1 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 50 Degree Wide Flood, eldoLED 0-10V, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462260252979,"sku":"Juno-AX3SQ-LPA-8794","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8794-2.jpg?v=1689639263"},{"product_id":"juno-ax3sq-lpa-8796","title":"Juno Aculux AX3SQ LPA 08LM 27K 90CRI 50D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 2700K Color, 90 CRI, 50 Degree Wide Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462266741043,"sku":"Juno-AX3SQ-LPA-8796","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8796-2_bf742ffb-9a49-452c-b31b-7790b875b1f5.jpg?v=1689639282"},{"product_id":"juno-ax3sq-lpa-8797","title":"Juno Aculux AX3SQ LPA 08LM 30K 80CRI 12D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 3000K Color, 80 CRI, 12 Degree Spot, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462270640435,"sku":"Juno-AX3SQ-LPA-8797","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8797-2.jpg?v=1689639293"},{"product_id":"juno-ax3sq-lpa-8798","title":"Juno Aculux AX3SQ LPA 08LM 30K 80CRI 12D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 3000K Color, 80 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462270771507,"sku":"Juno-AX3SQ-LPA-8798","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8798-2.jpg?v=1689639303"},{"product_id":"juno-ax3sq-lpa-8799","title":"Juno Aculux AX3SQ LPA 08LM 30K 80CRI 12D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 3000K Color, 80 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462270902579,"sku":"Juno-AX3SQ-LPA-8799","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8799-2.jpg?v=1689639313"},{"product_id":"juno-ax3sq-lpa-8802","title":"Juno Aculux AX3SQ LPA 08LM 30K 80CRI 12D EZ1 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 3000K Color, 80 CRI, 12 Degree Spot, eldoLED 0-10V, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462272082227,"sku":"Juno-AX3SQ-LPA-8802","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8802-2.jpg?v=1689639343"},{"product_id":"juno-ax3sq-lpa-8804","title":"Juno Aculux AX3SQ LPA 08LM 30K 80CRI 12D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 3000K Color, 80 CRI, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462272770355,"sku":"Juno-AX3SQ-LPA-8804","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8804-2.jpg?v=1689639363"},{"product_id":"juno-ax3sq-lpa-8805","title":"Juno Aculux AX3SQ LPA 08LM 30K 80CRI 24D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 3000K Color, 80 CRI, 24 Degree Narrow Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462273294643,"sku":"Juno-AX3SQ-LPA-8805","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8805-2_c21ffe1f-c0d7-4f06-adb2-4d34f44f1ef3.jpg?v=1689639373"},{"product_id":"juno-ax3sq-lpa-8807","title":"Juno Aculux AX3SQ LPA 08LM 30K 80CRI 24D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 3000K Color, 80 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462282993971,"sku":"Juno-AX3SQ-LPA-8807","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8807-2_6f6fd6b5-fd7f-47a8-b8c0-01f90f9ccd89.jpg?v=1689639393"},{"product_id":"juno-ax3sq-lpa-8809","title":"Juno Aculux AX3SQ LPA 08LM 30K 80CRI 24D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 3000K Color, 80 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462291022131,"sku":"Juno-AX3SQ-LPA-8809","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8809-2.jpg?v=1689639414"},{"product_id":"juno-ax3sq-lpa-8812","title":"Juno Aculux AX3SQ LPA 08LM 30K 80CRI 24D EZ1 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 3000K Color, 80 CRI, 24 Degree Narrow Flood, eldoLED 0-10V, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462293446963,"sku":"Juno-AX3SQ-LPA-8812","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8812-2.jpg?v=1689639443"},{"product_id":"juno-ax3sq-lpa-8815","title":"Juno Aculux AX3SQ LPA 08LM 30K 80CRI 24D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 800 Lumens, 3000K Color, 80 CRI, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462313632051,"sku":"Juno-AX3SQ-LPA-8815","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8815-2_f59bc06c-5b64-402c-90d8-c68ea3941d02.jpg?v=1689639473"}],"url":"https:\/\/electricbargainstores.com\/collections\/juno-aculux-recessed-lighting-ic408lpsq-low-profile-3-1-4-inch-led-housings.oembed","provider":"Electric Bargain Store","version":"1.0","type":"link"}