{"title":"Juno Aculux Recessed Lighting IC412LPSQ Low Profile 3-1\/4 inch LED Housings","description":"","products":[{"product_id":"juno-ax3sq-lpa-8933","title":"Juno Aculux AX3SQ LPA 12LM 27K 80CRI 12D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 80 CRI, 12 Degree Spot, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462401417523,"sku":"Juno-AX3SQ-LPA-8933","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8933-2_8abab2b3-07aa-454a-81a8-4746f0ea2057.jpg?v=1689640652"},{"product_id":"juno-ax3sq-lpa-8935","title":"Juno Aculux AX3SQ LPA 12LM 27K 80CRI 12D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 80 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462402105651,"sku":"Juno-AX3SQ-LPA-8935","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8935-2.jpg?v=1689640673"},{"product_id":"juno-ax3sq-lpa-8936","title":"Juno Aculux AX3SQ LPA 12LM 27K 80CRI 12D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 80 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462402138419,"sku":"Juno-AX3SQ-LPA-8936","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8936-2.jpg?v=1689640682"},{"product_id":"juno-ax3sq-lpa-8941","title":"Juno Aculux AX3SQ LPA 12LM 27K 80CRI 12D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 80 CRI, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462403186995,"sku":"Juno-AX3SQ-LPA-8941","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8941-2_32b3670c-c976-46ee-b5b3-a4ea87a770e5.jpg?v=1689640731"},{"product_id":"juno-ax3sq-lpa-8942","title":"Juno Aculux AX3SQ LPA 12LM 27K 80CRI 24D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 80 CRI, 24 Degree Narrow Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462403219763,"sku":"Juno-AX3SQ-LPA-8942","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8942-2.jpg?v=1689640741"},{"product_id":"juno-ax3sq-lpa-8943","title":"Juno Aculux AX3SQ LPA 12LM 27K 80CRI 24D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 80 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462404825395,"sku":"Juno-AX3SQ-LPA-8943","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8943-2.jpg?v=1689640751"},{"product_id":"juno-ax3sq-lpa-8944","title":"Juno Aculux AX3SQ LPA 12LM 27K 80CRI 24D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 80 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462404890931,"sku":"Juno-AX3SQ-LPA-8944","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8944-2_e146f829-7d12-41ac-b42b-8bcb668ea589.jpg?v=1689640760"},{"product_id":"juno-ax3sq-lpa-8949","title":"Juno Aculux AX3SQ LPA 12LM 27K 80CRI 24D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 80 CRI, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462406496563,"sku":"Juno-AX3SQ-LPA-8949","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8949-2.jpg?v=1689640810"},{"product_id":"juno-ax3sq-lpa-8950","title":"Juno Aculux AX3SQ LPA 12LM 27K 80CRI 35D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 80 CRI, 35 Degree Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462407217459,"sku":"Juno-AX3SQ-LPA-8950","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8950-2_b6ea10cf-89b2-4110-81fa-e21648cd6b4d.jpg?v=1689640821"},{"product_id":"juno-ax3sq-lpa-8951","title":"Juno Aculux AX3SQ LPA 12LM 27K 80CRI 35D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 80 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462407676211,"sku":"Juno-AX3SQ-LPA-8951","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8951-2_2bc389ae-7d14-4469-ad36-7fc9cd9a2330.jpg?v=1689640831"},{"product_id":"juno-ax3sq-lpa-8952","title":"Juno Aculux AX3SQ LPA 12LM 27K 80CRI 35D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 80 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462407807283,"sku":"Juno-AX3SQ-LPA-8952","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8952-2.jpg?v=1689640840"},{"product_id":"juno-ax3sq-lpa-8957","title":"Juno Aculux AX3SQ LPA 12LM 27K 80CRI 35D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 80 CRI, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462408692019,"sku":"Juno-AX3SQ-LPA-8957","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8957-2.jpg?v=1689640891"},{"product_id":"juno-ax3sq-lpa-8958","title":"Juno Aculux AX3SQ LPA 12LM 27K 80CRI 50D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 80 CRI, 50 Degree Wide Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462409085235,"sku":"Juno-AX3SQ-LPA-8958","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8958-2_02a404a0-0dec-4509-b4a3-5ab9a21813e0.jpg?v=1689640901"},{"product_id":"juno-ax3sq-lpa-8959","title":"Juno Aculux AX3SQ LPA 12LM 27K 80CRI 50D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 80 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462409314611,"sku":"Juno-AX3SQ-LPA-8959","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8959-2_bb4fdcfb-1b16-41d8-aa8e-f3a46b33c7de.jpg?v=1689640911"},{"product_id":"juno-ax3sq-lpa-8960","title":"Juno Aculux AX3SQ LPA 12LM 27K 80CRI 50D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 80 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462409543987,"sku":"Juno-AX3SQ-LPA-8960","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8960-2_d3cef6a9-11a3-4c84-b6ac-c414deb4953d.jpg?v=1689640920"},{"product_id":"juno-ax3sq-lpa-8966","title":"Juno Aculux AX3SQ LPA 12LM 27K 80CRI 50D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 80 CRI, 50 Degree Wide Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462412755251,"sku":"Juno-AX3SQ-LPA-8966","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8966-2_12b2f52b-6363-43d3-823b-14bad891d330.jpg?v=1689640980"},{"product_id":"juno-ax3sq-lpa-8967","title":"Juno Aculux AX3SQ LPA 12LM 27K 90CRI 12D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 90 CRI, 12 Degree Spot, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462413574451,"sku":"Juno-AX3SQ-LPA-8967","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8967-2_44ba145d-99bf-4792-a738-5089a3773a88.jpg?v=1689640990"},{"product_id":"juno-ax3sq-lpa-8968","title":"Juno Aculux AX3SQ LPA 12LM 27K 90CRI 12D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 90 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462413967667,"sku":"Juno-AX3SQ-LPA-8968","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8968-2_76c83bf2-386f-4c21-85a2-0a29e004ec92.jpg?v=1689640999"},{"product_id":"juno-ax3sq-lpa-8969","title":"Juno Aculux AX3SQ LPA 12LM 27K 90CRI 12D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 90 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462414983475,"sku":"Juno-AX3SQ-LPA-8969","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8969-2_56d7a539-84a1-4591-bfde-b9f659a8e0a4.jpg?v=1689641009"},{"product_id":"juno-ax3sq-lpa-8974","title":"Juno Aculux AX3SQ LPA 12LM 27K 90CRI 12D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 90 CRI, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462421209395,"sku":"Juno-AX3SQ-LPA-8974","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8974-2.jpg?v=1689641058"},{"product_id":"juno-ax3sq-lpa-8975","title":"Juno Aculux AX3SQ LPA 12LM 27K 90CRI 24D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 90 CRI, 24 Degree Narrow Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462423535923,"sku":"Juno-AX3SQ-LPA-8975","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8975-2_645f664d-6f77-47d6-ac95-063ca1ec5967.jpg?v=1689641067"},{"product_id":"juno-ax3sq-lpa-8977","title":"Juno Aculux AX3SQ LPA 12LM 27K 90CRI 24D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 90 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462425174323,"sku":"Juno-AX3SQ-LPA-8977","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8977-2.jpg?v=1689641087"},{"product_id":"juno-ax3sq-lpa-8978","title":"Juno Aculux AX3SQ LPA 12LM 27K 90CRI 24D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 90 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462425338163,"sku":"Juno-AX3SQ-LPA-8978","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8978-2_b743b0da-448c-4c2d-8971-958286d703e9.jpg?v=1689641097"},{"product_id":"juno-ax3sq-lpa-8983","title":"Juno Aculux AX3SQ LPA 12LM 27K 90CRI 24D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 90 CRI, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462427697459,"sku":"Juno-AX3SQ-LPA-8983","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8983-2_c45945d0-54c0-4fa5-887c-dac031d6f087.jpg?v=1689641146"},{"product_id":"juno-ax3sq-lpa-8984","title":"Juno Aculux AX3SQ LPA 12LM 27K 90CRI 35D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 90 CRI, 35 Degree Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462428025139,"sku":"Juno-AX3SQ-LPA-8984","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8984-2.jpg?v=1689641156"},{"product_id":"juno-ax3sq-lpa-8985","title":"Juno Aculux AX3SQ LPA 12LM 27K 90CRI 35D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 90 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462428647731,"sku":"Juno-AX3SQ-LPA-8985","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8985-2.jpg?v=1689641166"},{"product_id":"juno-ax3sq-lpa-8986","title":"Juno Aculux AX3SQ LPA 12LM 27K 90CRI 35D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 90 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462434840883,"sku":"Juno-AX3SQ-LPA-8986","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8986-2.jpg?v=1689641175"},{"product_id":"juno-ax3sq-lpa-8991","title":"Juno Aculux AX3SQ LPA 12LM 27K 90CRI 35D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 90 CRI, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462439788851,"sku":"Juno-AX3SQ-LPA-8991","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8991-2_b5782012-6a71-423c-8486-d5c1e5504b41.jpg?v=1689641223"},{"product_id":"juno-ax3sq-lpa-8992","title":"Juno Aculux AX3SQ LPA 12LM 27K 90CRI 50D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 90 CRI, 50 Degree Wide Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462440444211,"sku":"Juno-AX3SQ-LPA-8992","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8992-2_5af83161-08d1-4a53-9154-25834403739d.jpg?v=1689641232"},{"product_id":"juno-ax3sq-lpa-8993","title":"Juno Aculux AX3SQ LPA 12LM 27K 90CRI 50D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 90 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462440902963,"sku":"Juno-AX3SQ-LPA-8993","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8993-2.jpg?v=1689641242"},{"product_id":"juno-ax3sq-lpa-8994","title":"Juno Aculux AX3SQ LPA 12LM 27K 90CRI 50D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 90 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462441328947,"sku":"Juno-AX3SQ-LPA-8994","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8994-2_8501a748-62c0-4b39-a936-b7562871e568.jpg?v=1689641252"},{"product_id":"juno-ax3sq-lpa-8999","title":"Juno Aculux AX3SQ LPA 12LM 27K 90CRI 50D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 2700K Color, 90 CRI, 50 Degree Wide Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462457057587,"sku":"Juno-AX3SQ-LPA-8999","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-8999-2_1988ab17-d4c2-4123-b06c-7dd2df6b3ad1.jpg?v=1689641301"},{"product_id":"juno-ax3sq-lpa-9000","title":"Juno Aculux AX3SQ LPA 12LM 30K 80CRI 12D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 3000K Color, 80 CRI, 12 Degree Spot, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462457614643,"sku":"Juno-AX3SQ-LPA-9000","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-9000-2_596dfd2a-0735-412e-b08d-126c7cbc3a78.jpg?v=1689641311"},{"product_id":"juno-ax3sq-lpa-9001","title":"Juno Aculux AX3SQ LPA 12LM 30K 80CRI 12D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 3000K Color, 80 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462457844019,"sku":"Juno-AX3SQ-LPA-9001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-9001-2.jpg?v=1689641321"},{"product_id":"juno-ax3sq-lpa-9002","title":"Juno Aculux AX3SQ LPA 12LM 30K 80CRI 12D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 3000K Color, 80 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462458564915,"sku":"Juno-AX3SQ-LPA-9002","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-9002-2_5593f9be-b0e8-4b28-a7f8-2e39ca88aa3e.jpg?v=1689641330"},{"product_id":"juno-ax3sq-lpa-9007","title":"Juno Aculux AX3SQ LPA 12LM 30K 80CRI 12D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 3000K Color, 80 CRI, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462465446195,"sku":"Juno-AX3SQ-LPA-9007","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-9007-2.jpg?v=1689641379"},{"product_id":"juno-ax3sq-lpa-9008","title":"Juno Aculux AX3SQ LPA 12LM 30K 80CRI 24D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 3000K Color, 80 CRI, 24 Degree Narrow Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462465839411,"sku":"Juno-AX3SQ-LPA-9008","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-9008-2.jpg?v=1689641389"},{"product_id":"juno-ax3sq-lpa-9010","title":"Juno Aculux AX3SQ LPA 12LM 30K 80CRI 24D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 3000K Color, 80 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462467838259,"sku":"Juno-AX3SQ-LPA-9010","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-9010-2_87ed44b2-6e09-4bda-8a1c-a2d294970905.jpg?v=1689641409"},{"product_id":"juno-ax3sq-lpa-9011","title":"Juno Aculux AX3SQ LPA 12LM 30K 80CRI 24D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 3000K Color, 80 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462468493619,"sku":"Juno-AX3SQ-LPA-9011","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-9011-2.jpg?v=1689641419"},{"product_id":"juno-ax3sq-lpa-9016","title":"Juno Aculux AX3SQ LPA 12LM 30K 80CRI 24D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 3000K Color, 80 CRI, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462472655155,"sku":"Juno-AX3SQ-LPA-9016","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-9016-2_17d21b4e-af30-4aae-9f76-bddbdc256e32.jpg?v=1689641472"},{"product_id":"juno-ax3sq-lpa-9017","title":"Juno Aculux AX3SQ LPA 12LM 30K 80CRI 35D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 3000K Color, 80 CRI, 35 Degree Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462473244979,"sku":"Juno-AX3SQ-LPA-9017","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-9017-2.jpg?v=1689641482"},{"product_id":"juno-ax3sq-lpa-9018","title":"Juno Aculux AX3SQ LPA 12LM 30K 80CRI 35D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 3000K Color, 80 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462473834803,"sku":"Juno-AX3SQ-LPA-9018","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-9018-2_1e9a93a5-ee79-4a55-b90d-0f5861887fac.jpg?v=1689641491"},{"product_id":"juno-ax3sq-lpa-9019","title":"Juno Aculux AX3SQ LPA 12LM 30K 80CRI 35D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 3000K Color, 80 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462474064179,"sku":"Juno-AX3SQ-LPA-9019","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-9019-2_429feee5-ece3-4119-a90b-44a1e6ccb656.jpg?v=1689641501"},{"product_id":"juno-ax3sq-lpa-9024","title":"Juno Aculux AX3SQ LPA 12LM 30K 80CRI 35D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 3000K Color, 80 CRI, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462477701427,"sku":"Juno-AX3SQ-LPA-9024","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-9024-2_3ec2094a-8bd9-42e5-9686-feb9c5fe7789.jpg?v=1689641551"},{"product_id":"juno-ax3sq-lpa-9025","title":"Juno Aculux AX3SQ LPA 12LM 30K 80CRI 50D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 3000K Color, 80 CRI, 50 Degree Wide Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462478192947,"sku":"Juno-AX3SQ-LPA-9025","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-9025-2_2f6048e7-0e2e-490f-a3d7-2787128622b4.jpg?v=1689641561"},{"product_id":"juno-ax3sq-lpa-9026","title":"Juno Aculux AX3SQ LPA 12LM 30K 80CRI 50D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 3000K Color, 80 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462479503667,"sku":"Juno-AX3SQ-LPA-9026","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-9026-2_ca3b29d8-c99d-4f29-856e-7ecdb74aa3dd.jpg?v=1689641571"},{"product_id":"juno-ax3sq-lpa-9027","title":"Juno Aculux AX3SQ LPA 12LM 30K 80CRI 50D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 3000K Color, 80 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462479995187,"sku":"Juno-AX3SQ-LPA-9027","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-9027-2_a8b2d617-dc42-43e5-8cd5-55695e55fc16.jpg?v=1689641580"},{"product_id":"juno-ax3sq-lpa-9032","title":"Juno Aculux AX3SQ LPA 12LM 30K 80CRI 50D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 3000K Color, 80 CRI, 50 Degree Wide Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462483009843,"sku":"Juno-AX3SQ-LPA-9032","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-9032-2_79c7410a-a460-4939-91ad-850a7ed3348b.jpg?v=1689641630"},{"product_id":"juno-ax3sq-lpa-9033","title":"Juno Aculux AX3SQ LPA 12LM 30K 90CRI 12D DALI MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 3000K Color, 90 CRI, 12 Degree Spot, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462483206451,"sku":"Juno-AX3SQ-LPA-9033","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-9033-2_279480a0-5641-4f13-8cbd-4c07efea1fd9.jpg?v=1689641640"},{"product_id":"juno-ax3sq-lpa-9034","title":"Juno Aculux AX3SQ LPA 12LM 30K 90CRI 12D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Square Adjustable Low Profile Housing, 1200 Lumens, 3000K Color, 90 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, 45 degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flangeless reflectors utilize precision wound double torsion springs for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eFlange is same finish as reflector unless optional painted white flange is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eICAT housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eAX3SQ A 08LM\/12LM and AX3SQ LPA 08LM\/12LM (ICAT) are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n \u003c\/li\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures except for AX3SQ A 20LM ICAT also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line\u003c\/li\u003e\n \u003cli\u003ePlatform featuring +\/- 1\/2\" translation and +\/- 45 degree aperture rotation aids fixture alignment after installation, prior to drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 4 No. 12 AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" ? 1 5\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA4SQ-125 (7\/8\"-1 1\/4\"), CTA4SQ-163 (1 1\/4\"- 1 5\/8\") or CTA4SQ-200 (1 5\/8\" ? 2\")\u003c\/li\u003e\n \u003cli\u003eCTA4SQ not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3SQ-A-AX3SQ-LPA-ordering-information_4d7b111f-10f5-46b4-b84f-1c1154c73035.jpg?v=1761904036\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462489563443,"sku":"Juno-AX3SQ-LPA-9034","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3SQ-LPA-9034-2_8f261049-4fc7-4eab-a4f1-398799ba3fd5.jpg?v=1689641650"}],"url":"https:\/\/electricbargainstores.com\/collections\/juno-aculux-recessed-lighting-ic412lpsq-low-profile-3-1-4-inch-led-housings.oembed","provider":"Electric Bargain Store","version":"1.0","type":"link"}