{"title":"Juno Aculux Recessed Lighting IC415L 3-1\/4 inch LED Housings","description":"","products":[{"product_id":"juno-ax3-a-4418","title":"Juno Aculux AX3 A 15LM 27K 80CRI 12D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457006526771,"sku":"Juno-AX3-A-4418","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4418-2_9a1cd357-75fa-4b15-906c-1635ba2103c3.jpg?v=1689590518"},{"product_id":"juno-ax3-a-4420","title":"Juno Aculux AX3 A 15LM 27K 80CRI 12D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457010000179,"sku":"Juno-AX3-A-4420","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4420-2.jpg?v=1689590539"},{"product_id":"juno-ax3-a-4425","title":"Juno Aculux AX3 A 15LM 27K 80CRI 12D FPC 120 CP ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V, Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457015177523,"sku":"Juno-AX3-A-4425","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4425-2.jpg?v=1689590594"},{"product_id":"juno-ax3-a-4426","title":"Juno Aculux AX3 A 15LM 27K 80CRI 12D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457015570739,"sku":"Juno-AX3-A-4426","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4426-2.jpg?v=1689590605"},{"product_id":"juno-ax3-a-4432","title":"Juno Aculux AX3 A 15LM 27K 80CRI 24D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457019666739,"sku":"Juno-AX3-A-4432","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4432-2.jpg?v=1689590669"},{"product_id":"juno-ax3-a-4434","title":"Juno Aculux AX3 A 15LM 27K 80CRI 24D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457020682547,"sku":"Juno-AX3-A-4434","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4434-2_9b31083c-407c-4a28-9df2-7a27951aaf4b.jpg?v=1689590691"},{"product_id":"juno-ax3-a-4439","title":"Juno Aculux AX3 A 15LM 27K 80CRI 24D FPC 120 CP ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V, Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457027793203,"sku":"Juno-AX3-A-4439","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4439-2.jpg?v=1689590747"},{"product_id":"juno-ax3-a-4440","title":"Juno Aculux AX3 A 15LM 27K 80CRI 24D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457029366067,"sku":"Juno-AX3-A-4440","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4440-2_ba28fedf-b148-4704-8c41-f9d5948b5d84.jpg?v=1689590758"},{"product_id":"juno-ax3-a-4446","title":"Juno Aculux AX3 A 15LM 27K 80CRI 35D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457036312883,"sku":"Juno-AX3-A-4446","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4446-2.jpg?v=1689590823"},{"product_id":"juno-ax3-a-4448","title":"Juno Aculux AX3 A 15LM 27K 80CRI 35D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457037459763,"sku":"Juno-AX3-A-4448","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4448-2.jpg?v=1689590846"},{"product_id":"juno-ax3-a-4453","title":"Juno Aculux AX3 A 15LM 27K 80CRI 35D FPC 120 CP ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V, Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457039622451,"sku":"Juno-AX3-A-4453","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4453-2.jpg?v=1689590901"},{"product_id":"juno-ax3-a-4454","title":"Juno Aculux AX3 A 15LM 27K 80CRI 35D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457039851827,"sku":"Juno-AX3-A-4454","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4454-2.jpg?v=1689590912"},{"product_id":"juno-ax3-a-4460","title":"Juno Aculux AX3 A 15LM 27K 80CRI 50D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457042342195,"sku":"Juno-AX3-A-4460","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4460-2.jpg?v=1689590977"},{"product_id":"juno-ax3-a-4462","title":"Juno Aculux AX3 A 15LM 27K 80CRI 50D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457043849523,"sku":"Juno-AX3-A-4462","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4462-2_96700ed1-31f8-427f-8e57-ac263f5182a8.jpg?v=1689590999"},{"product_id":"juno-ax3-a-4467","title":"Juno Aculux AX3 A 15LM 27K 80CRI 50D FPC 120 CP ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 50 Degree Wide Flood, Phase Cut Dimming, 5% Dim, 120V, Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457050960179,"sku":"Juno-AX3-A-4467","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4467-2.jpg?v=1689591055"},{"product_id":"juno-ax3-a-4468","title":"Juno Aculux AX3 A 15LM 27K 80CRI 50D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 50 Degree Wide Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457052893491,"sku":"Juno-AX3-A-4468","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4468-2.jpg?v=1689591065"},{"product_id":"juno-ax3-a-4474","title":"Juno Aculux AX3 A 15LM 27K 90CRI 12D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457056891187,"sku":"Juno-AX3-A-4474","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4474-2.jpg?v=1689591132"},{"product_id":"juno-ax3-a-4476","title":"Juno Aculux AX3 A 15LM 27K 90CRI 12D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457059217715,"sku":"Juno-AX3-A-4476","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4476-2.jpg?v=1689591153"},{"product_id":"juno-ax3-a-4481","title":"Juno Aculux AX3 A 15LM 27K 90CRI 12D FPC 120 CP ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V, Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457063772467,"sku":"Juno-AX3-A-4481","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4481-2.jpg?v=1689591209"},{"product_id":"juno-ax3-a-4482","title":"Juno Aculux AX3 A 15LM 27K 90CRI 12D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457064395059,"sku":"Juno-AX3-A-4482","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4482-2_7800c3c9-30e2-46af-8e53-b154c601d58f.jpg?v=1689591219"},{"product_id":"juno-ax3-a-4488","title":"Juno Aculux AX3 A 15LM 27K 90CRI 24D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457071538483,"sku":"Juno-AX3-A-4488","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4488-2_f4383b75-279d-44ab-ba89-f9fd5c38b0ff.jpg?v=1689591284"},{"product_id":"juno-ax3-a-4490","title":"Juno Aculux AX3 A 15LM 27K 90CRI 24D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457072587059,"sku":"Juno-AX3-A-4490","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4490-2.jpg?v=1689591306"},{"product_id":"juno-ax3-a-4495","title":"Juno Aculux AX3 A 15LM 27K 90CRI 24D FPC 120 CP ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V, Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457076388147,"sku":"Juno-AX3-A-4495","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4495-2.jpg?v=1689591361"},{"product_id":"juno-ax3-a-4496","title":"Juno Aculux AX3 A 15LM 27K 90CRI 24D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457076912435,"sku":"Juno-AX3-A-4496","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4496-2.jpg?v=1689591372"},{"product_id":"juno-ax3-a-4502","title":"Juno Aculux AX3 A 15LM 27K 90CRI 35D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457082482995,"sku":"Juno-AX3-A-4502","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4502-2_770928ab-3490-4a25-9730-dda8e8f4ca94.jpg?v=1689591439"},{"product_id":"juno-ax3-a-4504","title":"Juno Aculux AX3 A 15LM 27K 90CRI 35D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457083466035,"sku":"Juno-AX3-A-4504","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4504-2.jpg?v=1689591461"},{"product_id":"juno-ax3-a-4509","title":"Juno Aculux AX3 A 15LM 27K 90CRI 35D FPC 120 CP ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V, Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457089823027,"sku":"Juno-AX3-A-4509","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4509-2.jpg?v=1689591516"},{"product_id":"juno-ax3-a-4510","title":"Juno Aculux AX3 A 15LM 27K 90CRI 35D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457090052403,"sku":"Juno-AX3-A-4510","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4510-2.jpg?v=1689591527"},{"product_id":"juno-ax3-a-4516","title":"Juno Aculux AX3 A 15LM 27K 90CRI 50D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457098473779,"sku":"Juno-AX3-A-4516","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4516-2_d2b23646-90ca-436e-b4c1-b018e593987d.jpg?v=1689591591"},{"product_id":"juno-ax3-a-4518","title":"Juno Aculux AX3 A 15LM 27K 90CRI 50D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457103094067,"sku":"Juno-AX3-A-4518","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4518-2.jpg?v=1689591615"},{"product_id":"juno-ax3-a-4523","title":"Juno Aculux AX3 A 15LM 27K 90CRI 50D FPC 120 CP ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 50 Degree Wide Flood, Phase Cut Dimming, 5% Dim, 120V, Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457116004659,"sku":"Juno-AX3-A-4523","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4523-2_4ef1ed18-bcbb-4aac-bd32-6d246aa903cf.jpg?v=1689591671"},{"product_id":"juno-ax3-a-4524","title":"Juno Aculux AX3 A 15LM 27K 90CRI 50D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 50 Degree Wide Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457117118771,"sku":"Juno-AX3-A-4524","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4524-2.jpg?v=1689591682"},{"product_id":"juno-ax3-a-4530","title":"Juno Aculux AX3 A 15LM 30K 80CRI 12D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457122656563,"sku":"Juno-AX3-A-4530","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4530-2.jpg?v=1689591751"},{"product_id":"juno-ax3-a-4532","title":"Juno Aculux AX3 A 15LM 30K 80CRI 12D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457124098355,"sku":"Juno-AX3-A-4532","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4532-2_e88e7f73-32c3-4387-a953-b6d5614c006b.jpg?v=1689591773"},{"product_id":"juno-ax3-a-4537","title":"Juno Aculux AX3 A 15LM 30K 80CRI 12D FPC 120 CP ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V, Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457127407923,"sku":"Juno-AX3-A-4537","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4537-2.jpg?v=1689591831"},{"product_id":"juno-ax3-a-4538","title":"Juno Aculux AX3 A 15LM 30K 80CRI 12D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457128063283,"sku":"Juno-AX3-A-4538","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4538-2.jpg?v=1689591843"},{"product_id":"juno-ax3-a-4544","title":"Juno Aculux AX3 A 15LM 30K 80CRI 24D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457133764915,"sku":"Juno-AX3-A-4544","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4544-2_60e1b55d-dd4f-4ba3-b6e6-8bfb7946df1d.jpg?v=1689591913"},{"product_id":"juno-ax3-a-4546","title":"Juno Aculux AX3 A 15LM 30K 80CRI 24D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457134715187,"sku":"Juno-AX3-A-4546","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4546-2.jpg?v=1689591936"},{"product_id":"juno-ax3-a-4551","title":"Juno Aculux AX3 A 15LM 30K 80CRI 24D FPC 120 CP ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V, Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457140121907,"sku":"Juno-AX3-A-4551","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4551-2.jpg?v=1689591995"},{"product_id":"juno-ax3-a-4552","title":"Juno Aculux AX3 A 15LM 30K 80CRI 24D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457140547891,"sku":"Juno-AX3-A-4552","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4552-2.jpg?v=1689592007"},{"product_id":"juno-ax3-a-4558","title":"Juno Aculux AX3 A 15LM 30K 80CRI 35D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457144578355,"sku":"Juno-AX3-A-4558","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4558-2.jpg?v=1689592080"},{"product_id":"juno-ax3-a-4560","title":"Juno Aculux AX3 A 15LM 30K 80CRI 35D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457147199795,"sku":"Juno-AX3-A-4560","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4560-2.jpg?v=1689592102"},{"product_id":"juno-ax3-a-4565","title":"Juno Aculux AX3 A 15LM 30K 80CRI 35D FPC 120 CP ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V, Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457150017843,"sku":"Juno-AX3-A-4565","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4565-2.jpg?v=1689592159"},{"product_id":"juno-ax3-a-4566","title":"Juno Aculux AX3 A 15LM 30K 80CRI 35D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457150378291,"sku":"Juno-AX3-A-4566","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4566-2_47900b1a-9ef7-468f-9458-6874e9a2018e.jpg?v=1689592170"},{"product_id":"juno-ax3-a-4572","title":"Juno Aculux AX3 A 15LM 30K 80CRI 50D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457153360179,"sku":"Juno-AX3-A-4572","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4572-2.jpg?v=1689592240"},{"product_id":"juno-ax3-a-4574","title":"Juno Aculux AX3 A 15LM 30K 80CRI 50D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457154113843,"sku":"Juno-AX3-A-4574","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4574-2.jpg?v=1689592262"},{"product_id":"juno-ax3-a-4580","title":"Juno Aculux AX3 A 15LM 30K 80CRI 50D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 80 CRI, 50 Degree Wide Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457158078771,"sku":"Juno-AX3-A-4580","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4580-2.jpg?v=1689592329"},{"product_id":"juno-ax3-a-4586","title":"Juno Aculux AX3 A 15LM 30K 90CRI 12D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457161388339,"sku":"Juno-AX3-A-4586","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4586-2.jpg?v=1689592396"},{"product_id":"juno-ax3-a-4588","title":"Juno Aculux AX3 A 15LM 30K 90CRI 12D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457162600755,"sku":"Juno-AX3-A-4588","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4588-2.jpg?v=1689592418"},{"product_id":"juno-ax3-a-4594","title":"Juno Aculux AX3 A 15LM 30K 90CRI 12D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 1500 Lumens, 90 CRI, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457166106931,"sku":"Juno-AX3-A-4594","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4594-2.jpg?v=1689592484"}],"url":"https:\/\/electricbargainstores.com\/collections\/juno-aculux-recessed-lighting-ic415l-3-1-4-inch-led-housings.oembed","provider":"Electric Bargain Store","version":"1.0","type":"link"}