{"title":"Juno Aculux Recessed Lighting IC420L 3-1\/4 inch LED Housings","description":"","products":[{"product_id":"juno-ax3-a-4757","title":"Juno Aculux AX3 A 20LM 27K 80CRI 12D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457296785715,"sku":"Juno-AX3-A-4757","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4757-2.jpg?v=1689594313"},{"product_id":"juno-ax3-a-4760","title":"Juno Aculux AX3 A 20LM 27K 80CRI 12D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457297178931,"sku":"Juno-AX3-A-4760","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4760-2.jpg?v=1689594345"},{"product_id":"juno-ax3-a-4771","title":"Juno Aculux AX3 A 20LM 27K 80CRI 12D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457300488499,"sku":"Juno-AX3-A-4771","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4771-2_566a09d4-8429-4844-8bf5-6d899729abef.jpg?v=1689594464"},{"product_id":"juno-ax3-a-4780","title":"Juno Aculux AX3 A 20LM 27K 80CRI 24D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457304092979,"sku":"Juno-AX3-A-4780","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4780-2.jpg?v=1689594560"},{"product_id":"juno-ax3-a-4783","title":"Juno Aculux AX3 A 20LM 27K 80CRI 24D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457304518963,"sku":"Juno-AX3-A-4783","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4783-2.jpg?v=1689594592"},{"product_id":"juno-ax3-a-4794","title":"Juno Aculux AX3 A 20LM 27K 80CRI 24D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457308221747,"sku":"Juno-AX3-A-4794","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4794-2.jpg?v=1689594713"},{"product_id":"juno-ax3-a-4803","title":"Juno Aculux AX3 A 20LM 27K 80CRI 35D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457310515507,"sku":"Juno-AX3-A-4803","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4803-2_79ece946-8b96-438e-9b25-ebc9af5444d8.jpg?v=1689594810"},{"product_id":"juno-ax3-a-4806","title":"Juno Aculux AX3 A 20LM 27K 80CRI 35D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457311007027,"sku":"Juno-AX3-A-4806","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4806-2.jpg?v=1689594842"},{"product_id":"juno-ax3-a-4817","title":"Juno Aculux AX3 A 20LM 27K 80CRI 35D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457317888307,"sku":"Juno-AX3-A-4817","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4817-2.jpg?v=1689594962"},{"product_id":"juno-ax3-a-4826","title":"Juno Aculux AX3 A 20LM 27K 80CRI 50D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457319297331,"sku":"Juno-AX3-A-4826","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4826-2_d7ce08ca-a272-4b76-9d9e-3afe0cbfe96c.jpg?v=1689595059"},{"product_id":"juno-ax3-a-4829","title":"Juno Aculux AX3 A 20LM 27K 80CRI 50D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457319493939,"sku":"Juno-AX3-A-4829","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4829-2_545bd147-8be0-4524-90dd-f6a5647d0cd3.jpg?v=1689595091"},{"product_id":"juno-ax3-a-4840","title":"Juno Aculux AX3 A 20LM 27K 80CRI 50D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 50 Degree Wide Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457322279219,"sku":"Juno-AX3-A-4840","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4840-2.jpg?v=1689595210"},{"product_id":"juno-ax3-a-4849","title":"Juno Aculux AX3 A 20LM 27K 90CRI 12D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 90 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457327948083,"sku":"Juno-AX3-A-4849","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4849-2.jpg?v=1689595313"},{"product_id":"juno-ax3-a-4852","title":"Juno Aculux AX3 A 20LM 27K 90CRI 12D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 90 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457329422643,"sku":"Juno-AX3-A-4852","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4852-2.jpg?v=1689595346"},{"product_id":"juno-ax3-a-4863","title":"Juno Aculux AX3 A 20LM 27K 90CRI 12D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 90 CRI, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457330143539,"sku":"Juno-AX3-A-4863","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4863-2.jpg?v=1689595466"},{"product_id":"juno-ax3-a-4872","title":"Juno Aculux AX3 A 20LM 27K 90CRI 24D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 90 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457331159347,"sku":"Juno-AX3-A-4872","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4872-2.jpg?v=1689595566"},{"product_id":"juno-ax3-a-4875","title":"Juno Aculux AX3 A 20LM 27K 90CRI 24D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 90 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457331487027,"sku":"Juno-AX3-A-4875","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4875-2.jpg?v=1689595599"},{"product_id":"juno-ax3-a-4886","title":"Juno Aculux AX3 A 20LM 27K 90CRI 24D FPC 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 90 CRI, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457332437299,"sku":"Juno-AX3-A-4886","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4886-2.jpg?v=1689595721"},{"product_id":"juno-ax3-a-4895","title":"Juno Aculux AX3 A 20LM 27K 90CRI 35D ECOS2 120 ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 90 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457333223731,"sku":"Juno-AX3-A-4895","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4895-2.jpg?v=1689595819"},{"product_id":"juno-ax3-a-4898","title":"Juno Aculux AX3 A 20LM 27K 90CRI 35D ECOS3 MVOLT ICAT Recessed Lighting 3 inch IC LED New Construction Adjustable Housing, 2000 Lumens, 90 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457333354803,"sku":"Juno-AX3-A-4898","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4898-2.jpg?v=1689595852"},{"product_id":"juno-ic420l-827-f-1","title":"Juno Aculux Recessed Lighting IC420L-827-F-1 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Flood Beam, 120V, Forward \u0026 Reverse Phase Dimming, 5%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465254068531,"sku":"Juno-IC420L-827-F-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-827-F-1-2_3a727a0c-c9f6-41b1-ba10-b7091f3f0b7e.jpg?v=1689694945"},{"product_id":"juno-ic420l-827-f-d","title":"Juno Aculux Recessed Lighting IC420L-827-F-D 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Flood Beam, 120V, Lutron Hi-Lume 2-Wire Dimming, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465254428979,"sku":"Juno-IC420L-827-F-D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-827-F-D-2_fe4f5034-232b-4bca-b310-69150c0189ed.jpg?v=1689694956"},{"product_id":"juno-ic420l-827-f-l","title":"Juno Aculux Recessed Lighting IC420L-827-F-L 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Flood Beam, 120-277V, Lutron Hi-Lume 3-Wire Dimming, Ecosystem Compatible, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465254854963,"sku":"Juno-IC420L-827-F-L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-827-F-L-2.jpg?v=1689694967"},{"product_id":"juno-ic420l-827-f-u","title":"Juno Aculux Recessed Lighting IC420L-827-F-U 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 2700K Color Temp, 80 CRI, Flood Beam, 120-277V, 0-10V Dimming, 10%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465255313715,"sku":"Juno-IC420L-827-F-U","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-827-F-U-2_1e73e104-764d-41cb-84ac-567bd62c1717.jpg?v=1689694979"},{"product_id":"juno-ic420l-827-n-1","title":"Juno Aculux Recessed Lighting IC420L-827-N-1 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Narrow Flood Beam, 120V, Forward \u0026 Reverse Phase Dimming, 5%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465256198451,"sku":"Juno-IC420L-827-N-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-827-N-1-2.jpg?v=1689694989"},{"product_id":"juno-ic420l-827-n-d","title":"Juno Aculux Recessed Lighting IC420L-827-N-D 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Narrow Flood Beam, 120V, Lutron Hi-Lume 2-Wire Dimming, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465256558899,"sku":"Juno-IC420L-827-N-D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-827-N-D-2_d37828da-bf4c-41ce-b181-be140d1bbd5f.jpg?v=1689695000"},{"product_id":"juno-ic420l-827-n-l","title":"Juno Aculux Recessed Lighting IC420L-827-N-L 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Narrow Flood Beam, 120-277V, Lutron Hi-Lume 3-Wire Dimming, Ecosystem Compatible, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465257247027,"sku":"Juno-IC420L-827-N-L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-827-N-L-2_3b5255c5-bfda-4fc4-9e7b-9676745317eb.jpg?v=1689695012"},{"product_id":"juno-ic420l-827-n-u","title":"Juno Aculux Recessed Lighting IC420L-827-N-U 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 2700K Color Temp, 80 CRI, Narrow Flood Beam, 120-277V, 0-10V Dimming, 10%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465257574707,"sku":"Juno-IC420L-827-N-U","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-827-N-U-2_42bbf93d-dc18-4bb6-8627-d5e3ec163eba.jpg?v=1689695022"},{"product_id":"juno-ic420l-827-s-1","title":"Juno Aculux Recessed Lighting IC420L-827-S-1 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Spot Beam, 120V, Forward \u0026 Reverse Phase Dimming, 5%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465258033459,"sku":"Juno-IC420L-827-S-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-827-S-1-2_83acc413-01cb-4dcc-ab04-197bc5d35c2b.jpg?v=1689695033"},{"product_id":"juno-ic420l-827-s-d","title":"Juno Aculux Recessed Lighting IC420L-827-S-D 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Spot Beam, 120V, Lutron Hi-Lume 2-Wire Dimming, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465258361139,"sku":"Juno-IC420L-827-S-D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-827-S-D-2_c02db8fd-25d9-49ca-947d-93726df95057.jpg?v=1689695044"},{"product_id":"juno-ic420l-827-s-l","title":"Juno Aculux Recessed Lighting IC420L-827-S-L 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Spot Beam, 120-277V, Lutron Hi-Lume 3-Wire Dimming, Ecosystem Compatible, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465258754355,"sku":"Juno-IC420L-827-S-L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-827-S-L-2.jpg?v=1689695055"},{"product_id":"juno-ic420l-827-s-u","title":"Juno Aculux Recessed Lighting IC420L-827-S-U 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 2700K Color Temp, 80 CRI, Spot Beam, 120-277V, 0-10V Dimming, 10%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465259311411,"sku":"Juno-IC420L-827-S-U","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-827-S-U-2.jpg?v=1689695066"},{"product_id":"juno-ic420l-827-w-1","title":"Juno Aculux Recessed Lighting IC420L-827-W-1 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Wide Flood Beam, 120V, Forward \u0026 Reverse Phase Dimming, 5%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465259606323,"sku":"Juno-IC420L-827-W-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-827-W-1-2_168f5bec-9cf6-4f3f-b4fb-46c827e25a61.jpg?v=1689695077"},{"product_id":"juno-ic420l-827-w-d","title":"Juno Aculux Recessed Lighting IC420L-827-W-D 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Wide Flood Beam, 120V, Lutron Hi-Lume 2-Wire Dimming, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465260130611,"sku":"Juno-IC420L-827-W-D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-827-W-D-2_57848bb3-1a4f-4fe0-a7c2-ac8f95adfa82.jpg?v=1689695088"},{"product_id":"juno-ic420l-827-w-l","title":"Juno Aculux Recessed Lighting IC420L-827-W-L 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Wide Flood Beam, 120-277V, Lutron Hi-Lume 3-Wire Dimming, Ecosystem Compatible, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465260359987,"sku":"Juno-IC420L-827-W-L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-827-W-L-2_3fcc04f5-d515-470f-b8d6-57a42e8b4fcf.jpg?v=1689695099"},{"product_id":"juno-ic420l-827-w-u","title":"Juno Aculux Recessed Lighting IC420L-827-W-U 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 2700K Color Temp, 80 CRI, Wide Flood Beam, 120-277V, 0-10V Dimming, 10%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465260785971,"sku":"Juno-IC420L-827-W-U","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-827-W-U-2.jpg?v=1689695110"},{"product_id":"juno-ic420l-830-f-1","title":"Juno Aculux Recessed Lighting IC420L-830-F-1 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Flood Beam, 120V, Forward \u0026 Reverse Phase Dimming, 5%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465260982579,"sku":"Juno-IC420L-830-F-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-830-F-1-2_7a2a89f0-9e95-4c61-b907-9037794b6b9e.jpg?v=1689695121"},{"product_id":"juno-ic420l-830-f-d","title":"Juno Aculux Recessed Lighting IC420L-830-F-D 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Flood Beam, 120V, Lutron Hi-Lume 2-Wire Dimming, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465261867315,"sku":"Juno-IC420L-830-F-D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-830-F-D-2.jpg?v=1689695132"},{"product_id":"juno-ic420l-830-f-l","title":"Juno Aculux Recessed Lighting IC420L-830-F-L 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Flood Beam, 120-277V, Lutron Hi-Lume 3-Wire Dimming, Ecosystem Compatible, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465262194995,"sku":"Juno-IC420L-830-F-L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-830-F-L-2_09186258-bade-404b-b86f-5a0913ca501f.jpg?v=1689695145"},{"product_id":"juno-ic420l-830-f-u","title":"Juno Aculux Recessed Lighting IC420L-830-F-U 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 3000K Color Temp, 80 CRI, Flood Beam, 120-277V, 0-10V Dimming, 10%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465262588211,"sku":"Juno-IC420L-830-F-U","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-830-F-U-2_e1509a10-96fb-43a7-97d8-ca4f11c843c1.jpg?v=1689695156"},{"product_id":"juno-ic420l-830-n-1","title":"Juno Aculux Recessed Lighting IC420L-830-N-1 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Narrow Flood Beam, 120V, Forward \u0026 Reverse Phase Dimming, 5%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465262850355,"sku":"Juno-IC420L-830-N-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-830-N-1-2_eacbdd63-96ec-435d-9fd2-da3c69667aad.jpg?v=1689695166"},{"product_id":"juno-ic420l-830-n-d","title":"Juno Aculux Recessed Lighting IC420L-830-N-D 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Narrow Flood Beam, 120V, Lutron Hi-Lume 2-Wire Dimming, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465263145267,"sku":"Juno-IC420L-830-N-D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-830-N-D-2.jpg?v=1689695177"},{"product_id":"juno-ic420l-830-n-l","title":"Juno Aculux Recessed Lighting IC420L-830-N-L 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Narrow Flood Beam, 120-277V, Lutron Hi-Lume 3-Wire Dimming, Ecosystem Compatible, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465263407411,"sku":"Juno-IC420L-830-N-L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-830-N-L-2.jpg?v=1689695189"},{"product_id":"juno-ic420l-830-n-u","title":"Juno Aculux Recessed Lighting IC420L-830-N-U 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 3000K Color Temp, 80 CRI, Narrow Flood Beam, 120-277V, 0-10V Dimming, 10%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465263702323,"sku":"Juno-IC420L-830-N-U","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-830-N-U-2_136ba09d-c35a-4f71-8587-fbb785f1670a.jpg?v=1689695200"},{"product_id":"juno-ic420l-830-s-1","title":"Juno Aculux Recessed Lighting IC420L-830-S-1 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Spot Beam, 120V, Forward \u0026 Reverse Phase Dimming, 5%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465264095539,"sku":"Juno-IC420L-830-S-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-830-S-1-2_976e4577-162c-45ff-bb1a-30ad51e2c3ff.jpg?v=1689695211"},{"product_id":"juno-ic420l-830-s-d","title":"Juno Aculux Recessed Lighting IC420L-830-S-D 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Spot Beam, 120V, Lutron Hi-Lume 2-Wire Dimming, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465264390451,"sku":"Juno-IC420L-830-S-D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-830-S-D-2_965c19c3-e87a-4937-87ea-556ce8d0a182.jpg?v=1689695221"},{"product_id":"juno-ic420l-830-s-l","title":"Juno Aculux Recessed Lighting IC420L-830-S-L 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Spot Beam, 120-277V, Lutron Hi-Lume 3-Wire Dimming, Ecosystem Compatible, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465264718131,"sku":"Juno-IC420L-830-S-L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-830-S-L-2_e39c37e4-f470-438f-8758-90ae4aa95dea.jpg?v=1689695233"},{"product_id":"juno-ic420l-830-s-u","title":"Juno Aculux Recessed Lighting IC420L-830-S-U 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 3000K Color Temp, 80 CRI, Spot Beam, 120-277V, 0-10V Dimming, 10%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465265013043,"sku":"Juno-IC420L-830-S-U","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-830-S-U-2.jpg?v=1689695244"},{"product_id":"juno-ic420l-830-w-1","title":"Juno Aculux Recessed Lighting IC420L-830-W-1 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Wide Flood Beam, 120V, Forward \u0026 Reverse Phase Dimming, 5%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465265209651,"sku":"Juno-IC420L-830-W-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-830-W-1-2_79eeb2d6-fadd-4daa-8fd9-b443d2ff8545.jpg?v=1689695255"},{"product_id":"juno-ic420l-830-w-d","title":"Juno Aculux Recessed Lighting IC420L-830-W-D 3-1\/4 inch LED New Construction Adjustable IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Wide Flood Beam, 120V, Lutron Hi-Lume 2-Wire Dimming, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45465265471795,"sku":"Juno-IC420L-830-W-D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-IC420L-830-W-D-2.jpg?v=1689695266"}],"url":"https:\/\/electricbargainstores.com\/collections\/juno-aculux-recessed-lighting-ic420l-3-1-4-inch-led-housings.oembed?page=3","provider":"Electric Bargain Store","version":"1.0","type":"link"}