{"title":"Juno Aculux Recessed Lighting IC43L 3-1\/4 inch LED Housings","description":"","products":[{"product_id":"juno-ax3-a-2386","title":"Juno Aculux AX3 A 08LM 27K 80CRI 24D ECOS3 MVOLT CP ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V , Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455794209075,"sku":"Juno-AX3-A-2386","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2386-2_c0edfec5-e258-439a-9b0d-06e95ab1c440.jpg?v=1689566024"},{"product_id":"juno-ax3-a-2387","title":"Juno Aculux AX3 A 08LM 27K 80CRI 24D ECOS3 MVOLT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455794241843,"sku":"Juno-AX3-A-2387","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2387-2.jpg?v=1689566034"},{"product_id":"juno-ax3-a-2388","title":"Juno Aculux AX3 A 08LM 27K 80CRI 24D EZ1 120 NLIGHT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 24 Degree Narrow Flood, eldoLED 0-10V, 1% Dim, 120V , nLight Dimming Pack Controls","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455794438451,"sku":"Juno-AX3-A-2388","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2388-2.jpg?v=1689566044"},{"product_id":"juno-ax3-a-2389","title":"Juno Aculux AX3 A 08LM 27K 80CRI 24D EZ1 277 NLIGHT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 24 Degree Narrow Flood, eldoLED 0-10V, 1% Dim, 277V , nLight Dimming Pack Controls","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455794471219,"sku":"Juno-AX3-A-2389","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2389-2_e67ed7b5-04a9-45ee-af4c-c558e91cd0ee.jpg?v=1689566054"},{"product_id":"juno-ax3-a-2390","title":"Juno Aculux AX3 A 08LM 27K 80CRI 24D EZ1 MVOLT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 24 Degree Narrow Flood, eldoLED 0-10V, 1% Dim, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455795650867,"sku":"Juno-AX3-A-2390","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2390-2.jpg?v=1689566064"},{"product_id":"juno-ax3-a-2391","title":"Juno Aculux AX3 A 08LM 27K 80CRI 24D EZB MVOLT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 24 Degree Narrow Flood, eldoLED 0-10V, \u003c1% Dim, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455795683635,"sku":"Juno-AX3-A-2391","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2391-2_49faa722-7532-4da3-a176-ba0dd166c0ae.jpg?v=1689566073"},{"product_id":"juno-ax3-a-2392","title":"Juno Aculux AX3 A 08LM 27K 80CRI 24D FPC 120 CP ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V , Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455795716403,"sku":"Juno-AX3-A-2392","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2392-2.jpg?v=1689566083"},{"product_id":"juno-ax3-a-2393","title":"Juno Aculux AX3 A 08LM 27K 80CRI 24D FPC 120 ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455795749171,"sku":"Juno-AX3-A-2393","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2393-2.jpg?v=1689566093"},{"product_id":"juno-ax3-a-2394","title":"Juno Aculux AX3 A 08LM 27K 80CRI 35D DALI MVOLT CP ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 35 Degree Flood, DALI Driver, 1% Dim, 120-277V , Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455795781939,"sku":"Juno-AX3-A-2394","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2394-2.jpg?v=1689566103"},{"product_id":"juno-ax3-a-2395","title":"Juno Aculux AX3 A 08LM 27K 80CRI 35D DALI MVOLT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 35 Degree Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455795814707,"sku":"Juno-AX3-A-2395","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2395-2_216b9f2f-d96b-4ed8-b221-7d07832a2e2b.jpg?v=1689566113"},{"product_id":"juno-ax3-a-2396","title":"Juno Aculux AX3 A 08LM 27K 80CRI 35D DMXR MVOLT CP ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 35 Degree Flood, DMX RDM Driver, 1% Dim, 120-277V , Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455795847475,"sku":"Juno-AX3-A-2396","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2396-2_94a0110f-0c71-4db1-8847-31f8512c62ef.jpg?v=1689566123"},{"product_id":"juno-ax3-a-2397","title":"Juno Aculux AX3 A 08LM 27K 80CRI 35D DMXR MVOLT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 35 Degree Flood, DMX RDM Driver, 1% Dim, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455795880243,"sku":"Juno-AX3-A-2397","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2397-2_c7014b15-f0fa-4839-8e00-11f42f56dfba.jpg?v=1689566133"},{"product_id":"juno-ax3-a-2398","title":"Juno Aculux AX3 A 08LM 27K 80CRI 35D ECOS2 120 CP ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V , Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455795913011,"sku":"Juno-AX3-A-2398","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2398-2_11f66e37-06be-4bfc-a9cc-66977295096f.jpg?v=1689566143"},{"product_id":"juno-ax3-a-2399","title":"Juno Aculux AX3 A 08LM 27K 80CRI 35D ECOS2 120 ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455795945779,"sku":"Juno-AX3-A-2399","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2399-2_f5be0a4b-ea63-4fe9-9017-aa5e0e5d4115.jpg?v=1689566152"},{"product_id":"juno-ax3-a-2400","title":"Juno Aculux AX3 A 08LM 27K 80CRI 35D ECOS3 MVOLT CP ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V , Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455795978547,"sku":"Juno-AX3-A-2400","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2400-2_80978c22-9f6a-4c9d-bc1a-a390ed5557bd.jpg?v=1689566162"},{"product_id":"juno-ax3-a-2401","title":"Juno Aculux AX3 A 08LM 27K 80CRI 35D ECOS3 MVOLT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455796011315,"sku":"Juno-AX3-A-2401","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2401-2_878eab34-6f2a-4b1d-89b0-5d06c59f0722.jpg?v=1689566172"},{"product_id":"juno-ax3-a-2402","title":"Juno Aculux AX3 A 08LM 27K 80CRI 35D EZ1 120 NLIGHT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 35 Degree Flood, eldoLED 0-10V, 1% Dim, 120V , nLight Dimming Pack Controls","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455796044083,"sku":"Juno-AX3-A-2402","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2402-2.jpg?v=1689566182"},{"product_id":"juno-ax3-a-2403","title":"Juno Aculux AX3 A 08LM 27K 80CRI 35D EZ1 277 NLIGHT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 35 Degree Flood, eldoLED 0-10V, 1% Dim, 277V , nLight Dimming Pack Controls","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455796076851,"sku":"Juno-AX3-A-2403","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2403-2_745989ec-88ab-4b72-804f-ccae4026db83.jpg?v=1689566192"},{"product_id":"juno-ax3-a-2404","title":"Juno Aculux AX3 A 08LM 27K 80CRI 35D EZ1 MVOLT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 35 Degree Flood, eldoLED 0-10V, 1% Dim, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455796207923,"sku":"Juno-AX3-A-2404","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2404-2_be5c9bb3-fd18-4440-b094-b3b572d910c2.jpg?v=1689566201"},{"product_id":"juno-ax3-a-2405","title":"Juno Aculux AX3 A 08LM 27K 80CRI 35D EZB MVOLT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 35 Degree Flood, eldoLED 0-10V, \u003c1% Dim, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455796273459,"sku":"Juno-AX3-A-2405","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2405-2_d85b473e-44f5-402d-bbcc-47a6572d873f.jpg?v=1689566211"},{"product_id":"juno-ax3-a-2406","title":"Juno Aculux AX3 A 08LM 27K 80CRI 35D FPC 120 CP ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V , Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455796306227,"sku":"Juno-AX3-A-2406","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2406-2_a4ccccce-179c-453f-acd3-0d35af1443f1.jpg?v=1689566221"},{"product_id":"juno-ax3-a-2407","title":"Juno Aculux AX3 A 08LM 27K 80CRI 35D FPC 120 ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455796338995,"sku":"Juno-AX3-A-2407","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2407-2_6a2d7b3e-bee4-46a6-b12d-e0673d68d7a0.jpg?v=1689566230"},{"product_id":"juno-ax3-a-2408","title":"Juno Aculux AX3 A 08LM 27K 80CRI 50D DALI MVOLT CP ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 50 Degree Wide Flood, DALI Driver, 1% Dim, 120-277V , Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455796404531,"sku":"Juno-AX3-A-2408","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2408-2.jpg?v=1689566240"},{"product_id":"juno-ax3-a-2409","title":"Juno Aculux AX3 A 08LM 27K 80CRI 50D DALI MVOLT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 50 Degree Wide Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455796437299,"sku":"Juno-AX3-A-2409","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2409-2_75a536c6-b815-4f0c-8768-b4a14ffa4707.jpg?v=1689566250"},{"product_id":"juno-ax3-a-2410","title":"Juno Aculux AX3 A 08LM 27K 80CRI 50D DMXR MVOLT CP ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 50 Degree Wide Flood, DMX RDM Driver, 1% Dim, 120-277V , Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455796470067,"sku":"Juno-AX3-A-2410","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2410-2_07d585ea-d481-4b46-a78a-dd99bfdd4ca8.jpg?v=1689566260"},{"product_id":"juno-ax3-a-2411","title":"Juno Aculux AX3 A 08LM 27K 80CRI 50D DMXR MVOLT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 50 Degree Wide Flood, DMX RDM Driver, 1% Dim, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455797551411,"sku":"Juno-AX3-A-2411","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2411-2_81bada50-0962-45db-bca3-bfeb9b06d33f.jpg?v=1689566270"},{"product_id":"juno-ax3-a-2412","title":"Juno Aculux AX3 A 08LM 27K 80CRI 50D ECOS2 120 CP ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 50 Degree Wide Flood, Lutron Hi-Lume A Series 2-Wire, 120V , Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455797584179,"sku":"Juno-AX3-A-2412","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2412-2.jpg?v=1689566280"},{"product_id":"juno-ax3-a-2413","title":"Juno Aculux AX3 A 08LM 27K 80CRI 50D ECOS2 120 ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 50 Degree Wide Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455797616947,"sku":"Juno-AX3-A-2413","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2413-2.jpg?v=1689566290"},{"product_id":"juno-ax3-a-2414","title":"Juno Aculux AX3 A 08LM 27K 80CRI 50D ECOS3 MVOLT CP ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 50 Degree Wide Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V , Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455797649715,"sku":"Juno-AX3-A-2414","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2414-2_6a68a515-cbfa-4992-aa85-dcf821d56e0e.jpg?v=1689566300"},{"product_id":"juno-ax3-a-2415","title":"Juno Aculux AX3 A 08LM 27K 80CRI 50D ECOS3 MVOLT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 50 Degree Wide Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455797715251,"sku":"Juno-AX3-A-2415","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2415-2_783e5900-6b47-4f75-8d7b-f981b793ce9f.jpg?v=1689566310"},{"product_id":"juno-ax3-a-2416","title":"Juno Aculux AX3 A 08LM 27K 80CRI 50D EZ1 120 NLIGHT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 50 Degree Wide Flood, eldoLED 0-10V, 1% Dim, 120V , nLight Dimming Pack Controls","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455797911859,"sku":"Juno-AX3-A-2416","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2416-2.jpg?v=1689566320"},{"product_id":"juno-ax3-a-2417","title":"Juno Aculux AX3 A 08LM 27K 80CRI 50D EZ1 277 NLIGHT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 50 Degree Wide Flood, eldoLED 0-10V, 1% Dim, 277V , nLight Dimming Pack Controls","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455797944627,"sku":"Juno-AX3-A-2417","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2417-2_e0efe2c0-72bf-4f9b-8c95-24b66d638492.jpg?v=1689566330"},{"product_id":"juno-ax3-a-2418","title":"Juno Aculux AX3 A 08LM 27K 80CRI 50D EZ1 MVOLT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 50 Degree Wide Flood, eldoLED 0-10V, 1% Dim, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455799451955,"sku":"Juno-AX3-A-2418","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2418-2_42fda267-a849-4086-b378-c7f26a963e3f.jpg?v=1689566339"},{"product_id":"juno-ax3-a-2419","title":"Juno Aculux AX3 A 08LM 27K 80CRI 50D EZB MVOLT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 50 Degree Wide Flood, eldoLED 0-10V, \u003c1% Dim, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455799484723,"sku":"Juno-AX3-A-2419","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2419-2.jpg?v=1689566349"},{"product_id":"juno-ax3-a-2420","title":"Juno Aculux AX3 A 08LM 27K 80CRI 50D FPC 120 CP ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 50 Degree Wide Flood, Phase Cut Dimming, 5% Dim, 120V , Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455799517491,"sku":"Juno-AX3-A-2420","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2420-2_d672ae4f-a267-4619-887d-e29fab832821.jpg?v=1689566359"},{"product_id":"juno-ax3-a-2421","title":"Juno Aculux AX3 A 08LM 27K 80CRI 50D FPC 120 ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 50 Degree Wide Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455799615795,"sku":"Juno-AX3-A-2421","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2421-2.jpg?v=1689566369"},{"product_id":"juno-ax3-a-2422","title":"Juno Aculux AX3 A 08LM 27K 90CRI 12D DALI MVOLT CP ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 12 Degree Spot, DALI Driver, 1% Dim, 120-277V , Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455799746867,"sku":"Juno-AX3-A-2422","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2422-2.jpg?v=1689566379"},{"product_id":"juno-ax3-a-2423","title":"Juno Aculux AX3 A 08LM 27K 90CRI 12D DALI MVOLT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 12 Degree Spot, DALI Driver, 1% Dim, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455800107315,"sku":"Juno-AX3-A-2423","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2423-2_57520392-b570-43b2-a7bb-afed16fe206e.jpg?v=1689566389"},{"product_id":"juno-ax3-a-2424","title":"Juno Aculux AX3 A 08LM 27K 90CRI 12D DMXR MVOLT CP ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 12 Degree Spot, DMX RDM Driver, 1% Dim, 120-277V , Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455800140083,"sku":"Juno-AX3-A-2424","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2424-2.jpg?v=1689566399"},{"product_id":"juno-ax3-a-2425","title":"Juno Aculux AX3 A 08LM 27K 90CRI 12D DMXR MVOLT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 12 Degree Spot, DMX RDM Driver, 1% Dim, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455800205619,"sku":"Juno-AX3-A-2425","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2425-2_0d037157-ed95-4dfe-8510-67fd908f3f20.jpg?v=1689566409"},{"product_id":"juno-ax3-a-2426","title":"Juno Aculux AX3 A 08LM 27K 90CRI 12D ECOS2 120 CP ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V , Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455800303923,"sku":"Juno-AX3-A-2426","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2426-2_0f609f1d-85d5-4756-9880-e6db0d84c044.jpg?v=1689566419"},{"product_id":"juno-ax3-a-2427","title":"Juno Aculux AX3 A 08LM 27K 90CRI 12D ECOS2 120 ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455800369459,"sku":"Juno-AX3-A-2427","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2427-2_89c7e71a-a811-494d-96de-d9bb395f529e.jpg?v=1689566429"},{"product_id":"juno-ax3-a-2428","title":"Juno Aculux AX3 A 08LM 27K 90CRI 12D ECOS3 MVOLT CP ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V , Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455800992051,"sku":"Juno-AX3-A-2428","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2428-2_f9a7f67d-4759-437a-9c1c-7bb892a35847.jpg?v=1689566438"},{"product_id":"juno-ax3-a-2429","title":"Juno Aculux AX3 A 08LM 27K 90CRI 12D ECOS3 MVOLT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455801123123,"sku":"Juno-AX3-A-2429","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2429-2_f17f36a3-a40d-4c4a-8f7f-2e8ecdce253a.jpg?v=1689566448"},{"product_id":"juno-ax3-a-2430","title":"Juno Aculux AX3 A 08LM 27K 90CRI 12D EZ1 120 NLIGHT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 12 Degree Spot, eldoLED 0-10V, 1% Dim, 120V , nLight Dimming Pack Controls","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455801155891,"sku":"Juno-AX3-A-2430","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2430-2_030bb0ad-decf-4dbd-be76-acdd75420032.jpg?v=1689566458"},{"product_id":"juno-ax3-a-2431","title":"Juno Aculux AX3 A 08LM 27K 90CRI 12D EZ1 277 NLIGHT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 12 Degree Spot, eldoLED 0-10V, 1% Dim, 277V , nLight Dimming Pack Controls","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455801221427,"sku":"Juno-AX3-A-2431","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2431-2_b0597f1e-bb77-4e6f-818b-9c7e9dfa8432.jpg?v=1689566468"},{"product_id":"juno-ax3-a-2432","title":"Juno Aculux AX3 A 08LM 27K 90CRI 12D EZ1 MVOLT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 12 Degree Spot, eldoLED 0-10V, 1% Dim, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455801254195,"sku":"Juno-AX3-A-2432","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2432-2_143a3a68-bb49-4901-bed3-c866edfd255f.jpg?v=1689566478"},{"product_id":"juno-ax3-a-2433","title":"Juno Aculux AX3 A 08LM 27K 90CRI 12D EZB MVOLT ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 12 Degree Spot, eldoLED 0-10V, \u003c1% Dim, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455801745715,"sku":"Juno-AX3-A-2433","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2433-2_4f843c2f-eb98-4217-bceb-9a4fed67fb38.jpg?v=1689566488"},{"product_id":"juno-ax3-a-2434","title":"Juno Aculux AX3 A 08LM 27K 90CRI 12D FPC 120 CP ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V , Chicago Plenum","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455802204467,"sku":"Juno-AX3-A-2434","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2434-2_06dbacbc-7aa9-42ed-8c67-e70cd843950b.jpg?v=1689566498"},{"product_id":"juno-ax3-a-2435","title":"Juno Aculux AX3 A 08LM 27K 90CRI 12D FPC 120 ICAT Recessed Lighting 3 inch LED New Construction Adjustable Housing, 800 Lumens, 2700K Color Temperature, 800 Lumens, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 800 delivered lumens. Depending on the optic, the fixture has up to 50? visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12? Spot, 24? Narrow Flood, 35? Flood and 50? wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20?, 30?, 40?, 45? and 60? FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim? precision geared hot-aiming achieves 370? rotation, 45? tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of seven drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_0cc0674d-35fc-4d1a-b881-59235ae7e177.pdf?v=1761843997\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45455802827059,"sku":"Juno-AX3-A-2435","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-2435-2.jpg?v=1689566508"}],"url":"https:\/\/electricbargainstores.com\/collections\/juno-aculux-recessed-lighting-ic43l-3-1-4-inch-led-housings-1.oembed","provider":"Electric Bargain Store","version":"1.0","type":"link"}