{"title":"Juno Aculux Recessed Lighting IC512L 4 inch Adjustable LED Housings","description":"","products":[{"product_id":"juno-ax4-a-6440","title":"Juno Aculux AX4 A 12LM 27K 80CRI 12D DALI MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 2700K Color, 12 Degree Spot, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462758916403,"sku":"Juno-AX4-A-6440","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6440-2_1cca1e98-d8fe-47b7-9029-2d730c8b3cfc.jpg?v=1689646650"},{"product_id":"juno-ax4-a-6441","title":"Juno Aculux AX4 A 12LM 27K 80CRI 12D DMXR MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 2700K Color, 12 Degree Spot, DMX,RDM Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462758981939,"sku":"Juno-AX4-A-6441","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6441-2_6c3add32-a52b-4726-b8a8-921459ad8402.jpg?v=1689646660"},{"product_id":"juno-ax4-a-6442","title":"Juno Aculux AX4 A 12LM 27K 80CRI 12D ECOS2 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 2700K Color, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462760259891,"sku":"Juno-AX4-A-6442","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6442-2.jpg?v=1689646670"},{"product_id":"juno-ax4-a-6443","title":"Juno Aculux AX4 A 12LM 27K 80CRI 12D ECOS3 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 2700K Color, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462760325427,"sku":"Juno-AX4-A-6443","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6443-2.jpg?v=1689646680"},{"product_id":"juno-ax4-a-6446","title":"Juno Aculux AX4 A 12LM 27K 80CRI 12D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 2700K Color, 12 Degree Spot, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462760554803,"sku":"Juno-AX4-A-6446","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6446-2_d4af1812-bca5-4c27-ae59-ed07cb7a6113.jpg?v=1689646711"},{"product_id":"juno-ax4-a-6449","title":"Juno Aculux AX4 A 12LM 27K 80CRI 12D EZB MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 2700K Color, 12 Degree Spot, eldoLED 0-10V, \u003c1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462760816947,"sku":"Juno-AX4-A-6449","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6449-2_b17ea02b-e0a4-43fc-bba8-1f8482a706ed.jpg?v=1689646741"},{"product_id":"juno-ax4-a-6450","title":"Juno Aculux AX4 A 12LM 27K 80CRI 12D FPC 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 2700K Color, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462760882483,"sku":"Juno-AX4-A-6450","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6450-2_e7046b98-96d9-498b-b1cb-3180ce235891.jpg?v=1689646752"},{"product_id":"juno-ax4-a-6455","title":"Juno Aculux AX4 A 12LM 27K 80CRI 35D FPC 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 2700K Color, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462762127667,"sku":"Juno-AX4-A-6455","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6455-2.jpg?v=1689646805"},{"product_id":"juno-ax4-a-6456","title":"Juno Aculux AX4 A 12LM 27K 80CRI 50D FPC 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 2700K Color, 50 Degree Wide Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462762291507,"sku":"Juno-AX4-A-6456","price":435.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6456-2_442a274c-dfd8-4fcd-8837-2313e4a1e345.jpg?v=1689646816"},{"product_id":"juno-ax4-a-6457","title":"Juno Aculux AX4 A 12LM 27K 90CRI 24D DALI MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 2700K Color, 24 Degree Narrow Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462762357043,"sku":"Juno-AX4-A-6457","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6457-2.jpg?v=1689646826"},{"product_id":"juno-ax4-a-6458","title":"Juno Aculux AX4 A 12LM 27K 90CRI 24D DMXR MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 2700K Color, 24 Degree Narrow Flood, DMX,RDM Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462762455347,"sku":"Juno-AX4-A-6458","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6458-2_eaff5282-8bb5-48b4-8bf6-f77edebf622a.jpg?v=1689646836"},{"product_id":"juno-ax4-a-6459","title":"Juno Aculux AX4 A 12LM 27K 90CRI 24D ECOS2 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 2700K Color, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462762520883,"sku":"Juno-AX4-A-6459","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6459-2_39cf229b-68fc-4076-926b-4447987a7c7f.jpg?v=1689646846"},{"product_id":"juno-ax4-a-6460","title":"Juno Aculux AX4 A 12LM 27K 90CRI 24D ECOS3 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 2700K Color, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462762586419,"sku":"Juno-AX4-A-6460","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6460-2.jpg?v=1689646857"},{"product_id":"juno-ax4-a-6463","title":"Juno Aculux AX4 A 12LM 27K 90CRI 24D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 2700K Color, 24 Degree Narrow Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462763307315,"sku":"Juno-AX4-A-6463","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6463-2.jpg?v=1689646888"},{"product_id":"juno-ax4-a-6466","title":"Juno Aculux AX4 A 12LM 27K 90CRI 24D EZB MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 2700K Color, 24 Degree Narrow Flood, eldoLED 0-10V, \u003c1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462763733299,"sku":"Juno-AX4-A-6466","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6466-2.jpg?v=1689646919"},{"product_id":"juno-ax4-a-6467","title":"Juno Aculux AX4 A 12LM 27K 90CRI 24D FPC 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 2700K Color, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462764224819,"sku":"Juno-AX4-A-6467","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6467-2_23749053-4064-4803-9529-92779c65de02.jpg?v=1689646929"},{"product_id":"juno-ax4-a-6468","title":"Juno Aculux AX4 A 12LM 27K 90CRI 35D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 2700K Color, 35 Degree Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462764323123,"sku":"Juno-AX4-A-6468","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6468-2.jpg?v=1689646939"},{"product_id":"juno-ax4-a-6469","title":"Juno Aculux AX4 A 12LM 30K 80CRI 24D DALI MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 24 Degree Narrow Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462764486963,"sku":"Juno-AX4-A-6469","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6469-2_06af35aa-06ea-4b36-aaca-8c2d1159bd91.jpg?v=1689646949"},{"product_id":"juno-ax4-a-6470","title":"Juno Aculux AX4 A 12LM 30K 80CRI 24D DMXR MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 24 Degree Narrow Flood, DMX,RDM Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462764552499,"sku":"Juno-AX4-A-6470","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6470-2_51a0b47d-5a00-48a6-ad6c-1dc7822fe485.jpg?v=1689646959"},{"product_id":"juno-ax4-a-6471","title":"Juno Aculux AX4 A 12LM 30K 80CRI 24D ECOS2 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462764683571,"sku":"Juno-AX4-A-6471","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6471-2_3b012e13-125f-42d7-9278-bf32c202de7c.jpg?v=1689646969"},{"product_id":"juno-ax4-a-6472","title":"Juno Aculux AX4 A 12LM 30K 80CRI 24D ECOS3 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462765568307,"sku":"Juno-AX4-A-6472","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6472-2_18ee7a2d-5ef1-4f9e-a3a2-66aaa73180f2.jpg?v=1689646980"},{"product_id":"juno-ax4-a-6475","title":"Juno Aculux AX4 A 12LM 30K 80CRI 24D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 24 Degree Narrow Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462766846259,"sku":"Juno-AX4-A-6475","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6475-2_f2243749-bc8e-4eaa-92a4-c0ee9a813305.jpg?v=1689647010"},{"product_id":"juno-ax4-a-6478","title":"Juno Aculux AX4 A 12LM 30K 80CRI 24D EZB MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 24 Degree Narrow Flood, eldoLED 0-10V, \u003c1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462767108403,"sku":"Juno-AX4-A-6478","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6478-2_979bad8c-48d1-4230-8325-d2855648c96f.jpg?v=1689647041"},{"product_id":"juno-ax4-a-6479","title":"Juno Aculux AX4 A 12LM 30K 80CRI 24D FPC 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462769991987,"sku":"Juno-AX4-A-6479","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6479-2.jpg?v=1689647051"},{"product_id":"juno-ax4-a-6480","title":"Juno Aculux AX4 A 12LM 30K 80CRI 35D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 35 Degree Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462770090291,"sku":"Juno-AX4-A-6480","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6480-2.jpg?v=1689647061"},{"product_id":"juno-ax4-a-6481","title":"Juno Aculux AX4 A 12LM 30K 80CRI 35D FPC 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462770254131,"sku":"Juno-AX4-A-6481","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6481-2_cae3a7f9-96e9-46dc-9c84-b9c57cc07631.jpg?v=1689647071"},{"product_id":"juno-ax4-a-6482","title":"Juno Aculux AX4 A 12LM 30K 80CRI 50D FPC 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 50 Degree Wide Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462770352435,"sku":"Juno-AX4-A-6482","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6482-2.jpg?v=1689647082"},{"product_id":"juno-ax4-a-6483","title":"Juno Aculux AX4 A 12LM 30K 90CRI 12D FPC 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462770417971,"sku":"Juno-AX4-A-6483","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6483-2_27c205e5-e883-41f9-a84f-adefe3c07526.jpg?v=1689647093"},{"product_id":"juno-ax4-a-6484","title":"Juno Aculux AX4 A 12LM 30K 90CRI 35D DALI MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 35 Degree Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462770516275,"sku":"Juno-AX4-A-6484","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6484-2_30e9773c-aa48-4353-9eaa-4aa0ed2decd9.jpg?v=1689647103"},{"product_id":"juno-ax4-a-6485","title":"Juno Aculux AX4 A 12LM 30K 90CRI 35D DMXR MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 35 Degree Flood, DMX,RDM Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462770581811,"sku":"Juno-AX4-A-6485","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6485-2.jpg?v=1689647114"},{"product_id":"juno-ax4-a-6486","title":"Juno Aculux AX4 A 12LM 30K 90CRI 35D ECOS2 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462770712883,"sku":"Juno-AX4-A-6486","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6486-2.jpg?v=1689647124"},{"product_id":"juno-ax4-a-6487","title":"Juno Aculux AX4 A 12LM 30K 90CRI 35D ECOS3 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462770876723,"sku":"Juno-AX4-A-6487","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6487-2_9b706c36-6326-47c4-8d6d-2a0af4657f19.jpg?v=1689647134"},{"product_id":"juno-ax4-a-6490","title":"Juno Aculux AX4 A 12LM 30K 90CRI 35D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 35 Degree Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462773236019,"sku":"Juno-AX4-A-6490","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6490-2.jpg?v=1689647164"},{"product_id":"juno-ax4-a-6493","title":"Juno Aculux AX4 A 12LM 30K 90CRI 35D EZB MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 35 Degree Flood, eldoLED 0-10V, \u003c1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462774481203,"sku":"Juno-AX4-A-6493","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6493-2.jpg?v=1689647194"},{"product_id":"juno-ax4-a-6494","title":"Juno Aculux AX4 A 12LM 30K 90CRI 35D FPC 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462774579507,"sku":"Juno-AX4-A-6494","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6494-2_f97fd957-dd9b-4aa3-8c88-4889cbbdaa2d.jpg?v=1689647204"},{"product_id":"juno-ax4-a-6495","title":"Juno Aculux AX4 A 12LM 30K 90CRI 50D ECOS3 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3000K Color, 50 Degree Wide Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462775005491,"sku":"Juno-AX4-A-6495","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6495-2.jpg?v=1689647214"},{"product_id":"juno-ax4-a-6496","title":"Juno Aculux AX4 A 12LM 35K 80CRI 35D DALI MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3500K Color, 35 Degree Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462775267635,"sku":"Juno-AX4-A-6496","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6496-2_75caef69-6f64-460b-b121-d379cd164a45.jpg?v=1689647224"},{"product_id":"juno-ax4-a-6497","title":"Juno Aculux AX4 A 12LM 35K 80CRI 35D DMXR MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3500K Color, 35 Degree Flood, DMX,RDM Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462775791923,"sku":"Juno-AX4-A-6497","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6497-2.jpg?v=1689647234"},{"product_id":"juno-ax4-a-6498","title":"Juno Aculux AX4 A 12LM 35K 80CRI 35D ECOS2 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3500K Color, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462775922995,"sku":"Juno-AX4-A-6498","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6498-2.jpg?v=1689647244"},{"product_id":"juno-ax4-a-6499","title":"Juno Aculux AX4 A 12LM 35K 80CRI 35D ECOS3 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3500K Color, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462776578355,"sku":"Juno-AX4-A-6499","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6499-2.jpg?v=1689647255"},{"product_id":"juno-ax4-a-6502","title":"Juno Aculux AX4 A 12LM 35K 80CRI 35D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3500K Color, 35 Degree Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462776873267,"sku":"Juno-AX4-A-6502","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6502-2_6d780c31-1031-4c30-90d3-91b2c8490042.jpg?v=1689647285"},{"product_id":"juno-ax4-a-6505","title":"Juno Aculux AX4 A 12LM 35K 80CRI 35D EZB MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3500K Color, 35 Degree Flood, eldoLED 0-10V, \u003c1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462777233715,"sku":"Juno-AX4-A-6505","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6505-2_822caffe-73c0-4db4-bebe-40b31cf7591c.jpg?v=1689647315"},{"product_id":"juno-ax4-a-6506","title":"Juno Aculux AX4 A 12LM 35K 80CRI 35D FPC 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3500K Color, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462777397555,"sku":"Juno-AX4-A-6506","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6506-2_e2a66ba9-5f0e-41e1-9ad3-3c5ac73b98cd.jpg?v=1689647325"},{"product_id":"juno-ax4-a-6507","title":"Juno Aculux AX4 A 12LM 35K 80CRI 50D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 3500K Color, 50 Degree Wide Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462777561395,"sku":"Juno-AX4-A-6507","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6507-2.jpg?v=1689647335"},{"product_id":"juno-ax4-a-6508","title":"Juno Aculux AX4 A 12LM 40K 80CRI 50D DALI MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 4000K Color, 50 Degree Wide Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462777921843,"sku":"Juno-AX4-A-6508","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6508-2_7805c644-55e0-4ff2-ad28-b236279148df.jpg?v=1689647344"},{"product_id":"juno-ax4-a-6509","title":"Juno Aculux AX4 A 12LM 40K 80CRI 50D DMXR MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 4000K Color, 50 Degree Wide Flood, DMX,RDM Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462778020147,"sku":"Juno-AX4-A-6509","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6509-2.jpg?v=1689647354"},{"product_id":"juno-ax4-a-6510","title":"Juno Aculux AX4 A 12LM 40K 80CRI 50D ECOS2 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 4000K Color, 50 Degree Wide Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462778151219,"sku":"Juno-AX4-A-6510","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6510-2.jpg?v=1689647364"},{"product_id":"juno-ax4-a-6511","title":"Juno Aculux AX4 A 12LM 40K 80CRI 50D ECOS3 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 4000K Color, 50 Degree Wide Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462778478899,"sku":"Juno-AX4-A-6511","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6511-2.jpg?v=1689647374"},{"product_id":"juno-ax4-a-6514","title":"Juno Aculux AX4 A 12LM 40K 80CRI 50D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 4000K Color, 50 Degree Wide Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462784278835,"sku":"Juno-AX4-A-6514","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6514-2_f5008d18-92ed-4e3b-8eb5-07befa4e0c1f.jpg?v=1689647403"},{"product_id":"juno-ax4-a-6517","title":"Juno Aculux AX4 A 12LM 40K 80CRI 50D EZB MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 1200 Lumens, 4000K Color, 50 Degree Wide Flood, eldoLED 0-10V, \u003c1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462787981619,"sku":"Juno-AX4-A-6517","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6517-2_366de4b2-f44b-4532-8ca6-3dc5a359955b.jpg?v=1689647433"}],"url":"https:\/\/electricbargainstores.com\/collections\/juno-aculux-recessed-lighting-ic512l-4-inch-adjustable-led-housings.oembed?page=3","provider":"Electric Bargain Store","version":"1.0","type":"link"}