{"title":"Juno Aculux Recessed Lighting IC527L 4 inch Adjustable LED Housings","description":"","products":[{"product_id":"juno-ax4-a-6675","title":"Juno Aculux AX4 A 27LM 27K 80CRI 12D DALI MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 2700K Color, 12 Degree Spot, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462876848435,"sku":"Juno-AX4-A-6675","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6675-2.jpg?v=1689649017"},{"product_id":"juno-ax4-a-6676","title":"Juno Aculux AX4 A 27LM 27K 80CRI 12D DMXR MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 2700K Color, 12 Degree Spot, DMX,RDM Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462877372723,"sku":"Juno-AX4-A-6676","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6676-2_93ee08dd-853c-46f6-a871-c4d50f8d9f4a.jpg?v=1689649026"},{"product_id":"juno-ax4-a-6677","title":"Juno Aculux AX4 A 27LM 27K 80CRI 12D ECOS2 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 2700K Color, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462877438259,"sku":"Juno-AX4-A-6677","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6677-2_543c1b17-4f2e-4d45-8013-4fc4eaf0e61a.jpg?v=1689649036"},{"product_id":"juno-ax4-a-6678","title":"Juno Aculux AX4 A 27LM 27K 80CRI 12D ECOS3 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 2700K Color, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462877667635,"sku":"Juno-AX4-A-6678","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6678-2_0680ba76-e78f-479a-8180-af35d861ea09.jpg?v=1689649046"},{"product_id":"juno-ax4-a-6681","title":"Juno Aculux AX4 A 27LM 27K 80CRI 12D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 2700K Color, 12 Degree Spot, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462878912819,"sku":"Juno-AX4-A-6681","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6681-2_a763aae8-921e-4e56-b6df-00b85465e0bd.jpg?v=1689649075"},{"product_id":"juno-ax4-a-6684","title":"Juno Aculux AX4 A 27LM 27K 80CRI 12D EZB MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 2700K Color, 12 Degree Spot, eldoLED 0-10V, \u003c1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462880092467,"sku":"Juno-AX4-A-6684","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6684-2.jpg?v=1689649105"},{"product_id":"juno-ax4-a-6685","title":"Juno Aculux AX4 A 27LM 27K 80CRI 12D FPC 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 2700K Color, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462880256307,"sku":"Juno-AX4-A-6685","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6685-2_b8ec9683-fcdd-44d3-8d8e-6a9675214a14.jpg?v=1689649115"},{"product_id":"juno-ax4-a-6688","title":"Juno Aculux AX4 A 27LM 27K 80CRI 35D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 2700K Color, 35 Degree Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462881042739,"sku":"Juno-AX4-A-6688","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6688-2_e2ca4b9d-44aa-47d9-bc80-b9af407db934.jpg?v=1689649144"},{"product_id":"juno-ax4-a-6691","title":"Juno Aculux AX4 A 27LM 27K 80CRI 50D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 2700K Color, 50 Degree Wide Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462881534259,"sku":"Juno-AX4-A-6691","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6691-2_606f84fc-e8fe-4058-bfda-ddf335d9bc43.jpg?v=1689649174"},{"product_id":"juno-ax4-a-6692","title":"Juno Aculux AX4 A 27LM 27K 90CRI 12D FPC 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 2700K Color, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462884811059,"sku":"Juno-AX4-A-6692","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6692-2.jpg?v=1689649183"},{"product_id":"juno-ax4-a-6693","title":"Juno Aculux AX4 A 27LM 27K 90CRI 24D DALI MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 2700K Color, 24 Degree Narrow Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462885269811,"sku":"Juno-AX4-A-6693","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6693-2_34e9b109-c993-4d96-989e-d17315f60295.jpg?v=1689649194"},{"product_id":"juno-ax4-a-6694","title":"Juno Aculux AX4 A 27LM 27K 90CRI 24D DMXR MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 2700K Color, 24 Degree Narrow Flood, DMX,RDM Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462885794099,"sku":"Juno-AX4-A-6694","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6694-2_be461340-8a10-41d5-bee4-957866a52e27.jpg?v=1689649203"},{"product_id":"juno-ax4-a-6695","title":"Juno Aculux AX4 A 27LM 27K 90CRI 24D ECOS2 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 2700K Color, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462887498035,"sku":"Juno-AX4-A-6695","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6695-2_826332ea-baad-48d7-a483-1268f6e5da70.jpg?v=1689649213"},{"product_id":"juno-ax4-a-6696","title":"Juno Aculux AX4 A 27LM 27K 90CRI 24D ECOS3 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 2700K Color, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462887727411,"sku":"Juno-AX4-A-6696","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6696-2_1956defc-2014-4622-8686-f7e4614c5f88.jpg?v=1689649223"},{"product_id":"juno-ax4-a-6699","title":"Juno Aculux AX4 A 27LM 27K 90CRI 24D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 2700K Color, 24 Degree Narrow Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462890086707,"sku":"Juno-AX4-A-6699","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6699-2.jpg?v=1689649253"},{"product_id":"juno-ax4-a-6702","title":"Juno Aculux AX4 A 27LM 27K 90CRI 24D EZB MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 2700K Color, 24 Degree Narrow Flood, eldoLED 0-10V, \u003c1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462890414387,"sku":"Juno-AX4-A-6702","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6702-2.jpg?v=1689649285"},{"product_id":"juno-ax4-a-6703","title":"Juno Aculux AX4 A 27LM 27K 90CRI 24D FPC 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 2700K Color, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462890512691,"sku":"Juno-AX4-A-6703","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6703-2.jpg?v=1689649295"},{"product_id":"juno-ax4-a-6704","title":"Juno Aculux AX4 A 27LM 27K 90CRI 35D FPC 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 2700K Color, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462890676531,"sku":"Juno-AX4-A-6704","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6704-2_62ef8dfe-a38c-4902-84c6-0547187f2b17.jpg?v=1689649305"},{"product_id":"juno-ax4-a-6705","title":"Juno Aculux AX4 A 27LM 30K 80CRI 24D DALI MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3000k Color, 24 Degree Narrow Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462890807603,"sku":"Juno-AX4-A-6705","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6705-2.jpg?v=1689649315"},{"product_id":"juno-ax4-a-6706","title":"Juno Aculux AX4 A 27LM 30K 80CRI 24D DMXR MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3000k Color, 24 Degree Narrow Flood, DMX,RDM Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462891233587,"sku":"Juno-AX4-A-6706","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6706-2.jpg?v=1689649325"},{"product_id":"juno-ax4-a-6707","title":"Juno Aculux AX4 A 27LM 30K 80CRI 24D ECOS2 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3000k Color, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462901391667,"sku":"Juno-AX4-A-6707","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6707-2_daa1450e-8a39-48d6-8a2a-cfb953cffcd7.jpg?v=1689649335"},{"product_id":"juno-ax4-a-6708","title":"Juno Aculux AX4 A 27LM 30K 80CRI 24D ECOS3 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3000k Color, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462901457203,"sku":"Juno-AX4-A-6708","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6708-2_beb4fa15-73d5-4744-bcdc-f0d149ac9765.jpg?v=1689649345"},{"product_id":"juno-ax4-a-6711","title":"Juno Aculux AX4 A 27LM 30K 80CRI 24D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3000k Color, 24 Degree Narrow Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462903062835,"sku":"Juno-AX4-A-6711","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6711-2_5ff2ae7d-1f96-42ff-91e7-4ebd0d5ced37.jpg?v=1689649375"},{"product_id":"juno-ax4-a-6714","title":"Juno Aculux AX4 A 27LM 30K 80CRI 24D EZB MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3000k Color, 24 Degree Narrow Flood, eldoLED 0-10V, \u003c1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462903456051,"sku":"Juno-AX4-A-6714","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6714-2.jpg?v=1689649405"},{"product_id":"juno-ax4-a-6715","title":"Juno Aculux AX4 A 27LM 30K 80CRI 24D FPC 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3000k Color, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462903816499,"sku":"Juno-AX4-A-6715","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6715-2.jpg?v=1689649415"},{"product_id":"juno-ax4-a-6716","title":"Juno Aculux AX4 A 27LM 30K 90CRI 24D ECOS3 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3000k Color, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462903980339,"sku":"Juno-AX4-A-6716","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6716-2.jpg?v=1689649424"},{"product_id":"juno-ax4-a-6717","title":"Juno Aculux AX4 A 27LM 30K 90CRI 35D DALI MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3000k Color, 35 Degree Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462904176947,"sku":"Juno-AX4-A-6717","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6717-2_05dda55e-05a2-48cd-97ec-c81c96c2102b.jpg?v=1689649434"},{"product_id":"juno-ax4-a-6718","title":"Juno Aculux AX4 A 27LM 30K 90CRI 35D DMXR MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3000k Color, 35 Degree Flood, DMX,RDM Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462904504627,"sku":"Juno-AX4-A-6718","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6718-2_a540365f-6719-4113-97d4-1d8bd2cbedd8.jpg?v=1689649444"},{"product_id":"juno-ax4-a-6719","title":"Juno Aculux AX4 A 27LM 30K 90CRI 35D ECOS2 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3000k Color, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462904668467,"sku":"Juno-AX4-A-6719","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6719-2.jpg?v=1689649454"},{"product_id":"juno-ax4-a-6720","title":"Juno Aculux AX4 A 27LM 30K 90CRI 35D ECOS3 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3000k Color, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462904799539,"sku":"Juno-AX4-A-6720","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6720-2_3fbb63c3-aab3-4b6e-8ca4-0a43f1a1d9fc.jpg?v=1689649464"},{"product_id":"juno-ax4-a-6723","title":"Juno Aculux AX4 A 27LM 30K 90CRI 35D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3000k Color, 35 Degree Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462905028915,"sku":"Juno-AX4-A-6723","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6723-2_07a1d198-1ca4-4f3b-90a4-bcfaffd2bd32.jpg?v=1689649493"},{"product_id":"juno-ax4-a-6726","title":"Juno Aculux AX4 A 27LM 30K 90CRI 35D EZB MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3000k Color, 35 Degree Flood, eldoLED 0-10V, \u003c1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462907552051,"sku":"Juno-AX4-A-6726","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6726-2.jpg?v=1689649522"},{"product_id":"juno-ax4-a-6727","title":"Juno Aculux AX4 A 27LM 30K 90CRI 35D FPC 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3000k Color, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462907650355,"sku":"Juno-AX4-A-6727","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6727-2.jpg?v=1689649533"},{"product_id":"juno-ax4-a-6728","title":"Juno Aculux AX4 A 27LM 30K 90CRI 50D ECOS3 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3000k Color, 50 Degree Wide Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462907715891,"sku":"Juno-AX4-A-6728","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6728-2.jpg?v=1689649543"},{"product_id":"juno-ax4-a-6729","title":"Juno Aculux AX4 A 27LM 35K 80CRI 35D DALI MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3500K Color, 35 Degree Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462908010803,"sku":"Juno-AX4-A-6729","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6729-2_895670de-71d8-435f-8ac4-fbecc7b4c718.jpg?v=1689649552"},{"product_id":"juno-ax4-a-6730","title":"Juno Aculux AX4 A 27LM 35K 80CRI 35D DMXR MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3500K Color, 35 Degree Flood, DMX,RDM Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462908797235,"sku":"Juno-AX4-A-6730","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6730-2.jpg?v=1689649562"},{"product_id":"juno-ax4-a-6731","title":"Juno Aculux AX4 A 27LM 35K 80CRI 35D ECOS2 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3500K Color, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462908895539,"sku":"Juno-AX4-A-6731","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6731-2_f70b3b4d-49b6-41e0-9022-2478cd7a4472.jpg?v=1689649572"},{"product_id":"juno-ax4-a-6732","title":"Juno Aculux AX4 A 27LM 35K 80CRI 35D ECOS3 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3500K Color, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462908928307,"sku":"Juno-AX4-A-6732","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6732-2.jpg?v=1689649582"},{"product_id":"juno-ax4-a-6735","title":"Juno Aculux AX4 A 27LM 35K 80CRI 35D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3500K Color, 35 Degree Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462911156531,"sku":"Juno-AX4-A-6735","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6735-2.jpg?v=1689649612"},{"product_id":"juno-ax4-a-6738","title":"Juno Aculux AX4 A 27LM 35K 80CRI 35D EZB MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3500K Color, 35 Degree Flood, eldoLED 0-10V, \u003c1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462913155379,"sku":"Juno-AX4-A-6738","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6738-2_e2ffb571-26de-4521-ae5c-01aaf9abb107.jpg?v=1689649642"},{"product_id":"juno-ax4-a-6739","title":"Juno Aculux AX4 A 27LM 35K 80CRI 35D FPC 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3500K Color, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462913253683,"sku":"Juno-AX4-A-6739","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6739-2_833ab3be-ce52-453c-bee9-ebc5a9176cbf.jpg?v=1689649652"},{"product_id":"juno-ax4-a-6740","title":"Juno Aculux AX4 A 27LM 35K 80CRI 50D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 3500K Color, 50 Degree Wide Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462913351987,"sku":"Juno-AX4-A-6740","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6740-2_8d371dc5-d912-4d3b-9db5-6fed762980c2.jpg?v=1689649662"},{"product_id":"juno-ax4-a-6741","title":"Juno Aculux AX4 A 27LM 40K 80CRI 35D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 4000K Color, 35 Degree Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462913384755,"sku":"Juno-AX4-A-6741","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6741-2.jpg?v=1689649672"},{"product_id":"juno-ax4-a-6742","title":"Juno Aculux AX4 A 27LM 40K 80CRI 50D DALI MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 4000K Color, 50 Degree Wide Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462913450291,"sku":"Juno-AX4-A-6742","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6742-2_034b3284-cf4c-4520-89c6-39af56cd6bb6.jpg?v=1689649682"},{"product_id":"juno-ax4-a-6743","title":"Juno Aculux AX4 A 27LM 40K 80CRI 50D DMXR MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 4000K Color, 50 Degree Wide Flood, DMX,RDM Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462913614131,"sku":"Juno-AX4-A-6743","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6743-2_55b9ec1f-09a4-4e08-920d-10f64e5c5afe.jpg?v=1689649692"},{"product_id":"juno-ax4-a-6744","title":"Juno Aculux AX4 A 27LM 40K 80CRI 50D ECOS2 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 4000K Color, 50 Degree Wide Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462913712435,"sku":"Juno-AX4-A-6744","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6744-2.jpg?v=1689649702"},{"product_id":"juno-ax4-a-6745","title":"Juno Aculux AX4 A 27LM 40K 80CRI 50D ECOS3 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 4000K Color, 50 Degree Wide Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462913777971,"sku":"Juno-AX4-A-6745","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6745-2_8aee5382-a38e-49a1-b829-601211bbbcd3.jpg?v=1689649712"},{"product_id":"juno-ax4-a-6748","title":"Juno Aculux AX4 A 27LM 40K 80CRI 50D EZ1 MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 4000K Color, 50 Degree Wide Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462914400563,"sku":"Juno-AX4-A-6748","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6748-2.jpg?v=1689649742"},{"product_id":"juno-ax4-a-6751","title":"Juno Aculux AX4 A 27LM 40K 80CRI 50D EZB MVOLT ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 4000K Color, 50 Degree Wide Flood, eldoLED 0-10V, \u003c1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462914728243,"sku":"Juno-AX4-A-6751","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6751-2_a661c9b0-f046-4bdf-ab8f-df2f3ac32846.jpg?v=1689649772"},{"product_id":"juno-ax4-a-6752","title":"Juno Aculux AX4 A 27LM 40K 80CRI 50D FPC 120 ICAT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 2700 Lumens, 4000K Color, 50 Degree Wide Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462914826547,"sku":"Juno-AX4-A-6752","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6752-2.jpg?v=1689649782"}],"url":"https:\/\/electricbargainstores.com\/collections\/juno-aculux-recessed-lighting-ic527l-4-inch-adjustable-led-housings.oembed","provider":"Electric Bargain Store","version":"1.0","type":"link"}