{"title":"Juno Aculux Recessed Lighting TC420L 3-1\/4 inch LED Housings","description":"","products":[{"product_id":"juno-ax3-a-4755","title":"Juno Aculux AX3 A 20LM 27K 80CRI 12D ECOS2 120 Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457296097587,"sku":"Juno-AX3-A-4755","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4755-2.jpg?v=1689594291"},{"product_id":"juno-ax3-a-4758","title":"Juno Aculux AX3 A 20LM 27K 80CRI 12D ECOS3 MVOLT Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457296884019,"sku":"Juno-AX3-A-4758","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4758-2.jpg?v=1689594323"},{"product_id":"juno-ax3-a-4769","title":"Juno Aculux AX3 A 20LM 27K 80CRI 12D FPC 120 Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457300193587,"sku":"Juno-AX3-A-4769","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4769-2.jpg?v=1689594443"},{"product_id":"juno-ax3-a-4778","title":"Juno Aculux AX3 A 20LM 27K 80CRI 24D ECOS2 120 Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457301176627,"sku":"Juno-AX3-A-4778","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4778-2.jpg?v=1689594538"},{"product_id":"juno-ax3-a-4781","title":"Juno Aculux AX3 A 20LM 27K 80CRI 24D ECOS3 MVOLT Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457304191283,"sku":"Juno-AX3-A-4781","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4781-2_30d19ff9-3057-456a-a6f2-e5bff83a665d.jpg?v=1689594571"},{"product_id":"juno-ax3-a-4792","title":"Juno Aculux AX3 A 20LM 27K 80CRI 24D FPC 120 Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457308090675,"sku":"Juno-AX3-A-4792","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4792-2.jpg?v=1689594691"},{"product_id":"juno-ax3-a-4801","title":"Juno Aculux AX3 A 20LM 27K 80CRI 35D ECOS2 120 Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457310023987,"sku":"Juno-AX3-A-4801","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4801-2.jpg?v=1689594788"},{"product_id":"juno-ax3-a-4804","title":"Juno Aculux AX3 A 20LM 27K 80CRI 35D ECOS3 MVOLT Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457310581043,"sku":"Juno-AX3-A-4804","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4804-2.jpg?v=1689594820"},{"product_id":"juno-ax3-a-4815","title":"Juno Aculux AX3 A 20LM 27K 80CRI 35D FPC 120 Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457315496243,"sku":"Juno-AX3-A-4815","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4815-2.jpg?v=1689594939"},{"product_id":"juno-ax3-a-4824","title":"Juno Aculux AX3 A 20LM 27K 80CRI 50D ECOS2 120 Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457319100723,"sku":"Juno-AX3-A-4824","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4824-2_c18892f8-83b6-4c3d-b60c-35042de3ae06.jpg?v=1689595037"},{"product_id":"juno-ax3-a-4827","title":"Juno Aculux AX3 A 20LM 27K 80CRI 50D ECOS3 MVOLT Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 50 Degree Wide Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457319330099,"sku":"Juno-AX3-A-4827","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4827-2.jpg?v=1689595070"},{"product_id":"juno-ax3-a-4838","title":"Juno Aculux AX3 A 20LM 27K 80CRI 50D FPC 120 Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 80 CRI, 50 Degree Wide Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457322180915,"sku":"Juno-AX3-A-4838","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4838-2_ba46cf13-d199-4704-91f2-57a9af8bd5e9.jpg?v=1689595188"},{"product_id":"juno-ax3-a-4847","title":"Juno Aculux AX3 A 20LM 27K 90CRI 12D ECOS2 120 Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 90 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457326178611,"sku":"Juno-AX3-A-4847","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4847-2.jpg?v=1689595291"},{"product_id":"juno-ax3-a-4850","title":"Juno Aculux AX3 A 20LM 27K 90CRI 12D ECOS3 MVOLT Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 90 CRI, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457328341299,"sku":"Juno-AX3-A-4850","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4850-2.jpg?v=1689595324"},{"product_id":"juno-ax3-a-4861","title":"Juno Aculux AX3 A 20LM 27K 90CRI 12D FPC 120 Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 90 CRI, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457330045235,"sku":"Juno-AX3-A-4861","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4861-2.jpg?v=1689595444"},{"product_id":"juno-ax3-a-4870","title":"Juno Aculux AX3 A 20LM 27K 90CRI 24D ECOS2 120 Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 90 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457331028275,"sku":"Juno-AX3-A-4870","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4870-2.jpg?v=1689595543"},{"product_id":"juno-ax3-a-4873","title":"Juno Aculux AX3 A 20LM 27K 90CRI 24D ECOS3 MVOLT Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 90 CRI, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457331192115,"sku":"Juno-AX3-A-4873","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4873-2_b8df9e8d-825d-47dd-9921-97cc833857b2.jpg?v=1689595577"},{"product_id":"juno-ax3-a-4884","title":"Juno Aculux AX3 A 20LM 27K 90CRI 24D FPC 120 Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 90 CRI, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457332175155,"sku":"Juno-AX3-A-4884","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4884-2_12d4f776-6b48-4a19-bdf6-334ec6073725.jpg?v=1689595699"},{"product_id":"juno-ax3-a-4893","title":"Juno Aculux AX3 A 20LM 27K 90CRI 35D ECOS2 120 Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 90 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457333059891,"sku":"Juno-AX3-A-4893","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4893-2_d24de254-6aee-4849-9b2e-7885142cdf99.jpg?v=1689595797"},{"product_id":"juno-ax3-a-4896","title":"Juno Aculux AX3 A 20LM 27K 90CRI 35D ECOS3 MVOLT Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 90 CRI, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457333256499,"sku":"Juno-AX3-A-4896","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4896-2.jpg?v=1689595830"},{"product_id":"juno-ax3-a-4907","title":"Juno Aculux AX3 A 20LM 27K 90CRI 35D FPC 120 Recessed Lighting 3 inch non IC LED New Construction Adjustable Housing, 2000 Lumens, 90 CRI, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n Recessed adjustable LED luminaire produces up to 1200 delivered lumens. Depending on the optic, the fixture has up to 50 Degree\n \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. IC rated luminaires can be used in insulated or non-insulated areas. \u003c\/span\u003eWhereas non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3? from housing.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 Degree Spot, 24 Degree Narrow Flood, 35 Degree Flood and 50 Degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 Degree, 30 Degree, 40 Degree, 45 Degree and 60 Degree FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 Degree rotation, 45 Degree tilt\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-ACLXLED3-DIM_pdf_63f55b64-1010-4da9-bdc9-77279c98d5f9.pdf?v=1761846696\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX3-A-AX3-LPA-ordering-information_5c99b3b5-c99b-4b90-97f6-a716d497391d.jpg?v=1761843996\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45457350983987,"sku":"Juno-AX3-A-4907","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX3-A-4907-2.jpg?v=1689595951"},{"product_id":"juno-tc420l-827-f-1","title":"Juno Aculux Recessed Lighting TC420L-827-F-1 (AX3 A 20LM 27K 80CRI 35D FPC 120) 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Flood Beam, 120V, Forward \u0026 Reverse Phase Dimming, 5%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481094807859,"sku":"Juno-TC420L-827-F-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-827-F-1-2.jpg?v=1690035573"},{"product_id":"juno-tc420l-827-f-d","title":"Juno Aculux Recessed Lighting TC420L-827-F-D (AX3 A 20LM 27K 80CRI 35D ECOS2 120) 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Flood Beam, 120V, Lutron Hi-Lume 2-Wire Dimming, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481094971699,"sku":"Juno-TC420L-827-F-D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-827-F-D-2.jpg?v=1690035585"},{"product_id":"juno-tc420l-827-f-l","title":"Juno Aculux Recessed Lighting TC420L-827-F-L 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Flood Beam, 120-277V, Lutron Hi-Lume 3-Wire Dimming, Ecosystem Compatible, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481098150195,"sku":"Juno-TC420L-827-F-L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-827-F-L-2.jpg?v=1690035596"},{"product_id":"juno-tc420l-827-f-u","title":"Juno Aculux TC420L-827-F-U  Recessed Lighting  3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 2700K Color Temp, 80 CRI, Flood Beam, 120-277V, 0-10V Dimming, 10%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481098641715,"sku":"Juno-TC420L-827-F-U","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-827-F-U-2.jpg?v=1690035607"},{"product_id":"juno-tc420l-827-n-1","title":"Juno Aculux Recessed Lighting TC420L-827-N-1 (AX3 A 20LM 27K 80CRI 24D FPC 120) 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Narrow Flood Beam, 120V, Forward \u0026 Reverse Phase Dimming, 5%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481098805555,"sku":"Juno-TC420L-827-N-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-827-N-1-2.jpg?v=1690035619"},{"product_id":"juno-tc420l-827-n-d","title":"Juno Aculux Recessed Lighting TC420L-827-N-D (AX3 A 20LM 27K 80CRI 24D ECOS2 120) 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Narrow Flood Beam, 120V, Lutron Hi-Lume 2-Wire Dimming, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481099034931,"sku":"Juno-TC420L-827-N-D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-827-N-D-2.jpg?v=1690035630"},{"product_id":"juno-tc420l-827-n-l","title":"Juno Aculux Recessed Lighting TC420L-827-N-L 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Narrow Flood Beam, 120-277V, Lutron Hi-Lume 3-Wire Dimming, Ecosystem Compatible, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481099198771,"sku":"Juno-TC420L-827-N-L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-827-N-L-2.jpg?v=1690035642"},{"product_id":"juno-tc420l-827-n-u","title":"Juno Aculux TC420L-827-N-U  Recessed Lighting  3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 2700K Color Temp, 80 CRI, Narrow Flood Beam, 120-277V, 0-10V Dimming, 10%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481099854131,"sku":"Juno-TC420L-827-N-U","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-827-N-U-2.jpg?v=1690035653"},{"product_id":"juno-tc420l-827-s-1","title":"Juno Aculux Recessed Lighting TC420L-827-S-1 (AX3 A 20LM 27K 80CRI 12D FPC 120) 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Spot Beam, 120V, Forward \u0026 Reverse Phase Dimming, 5%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481100247347,"sku":"Juno-TC420L-827-S-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-827-S-1-2.jpg?v=1690035665"},{"product_id":"juno-tc420l-827-s-d","title":"Juno Aculux Recessed Lighting TC420L-827-S-D (AX3 A 20LM 27K 80CRI 12D ECOS2 120) 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Spot Beam, 120V, Lutron Hi-Lume 2-Wire Dimming, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481100411187,"sku":"Juno-TC420L-827-S-D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-827-S-D-2.jpg?v=1690035676"},{"product_id":"juno-tc420l-827-s-l","title":"Juno Aculux Recessed Lighting TC420L-827-S-L 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Spot Beam, 120-277V, Lutron Hi-Lume 3-Wire Dimming, Ecosystem Compatible, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481100607795,"sku":"Juno-TC420L-827-S-L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-827-S-L-2.jpg?v=1690035687"},{"product_id":"juno-tc420l-827-s-u","title":"Juno Aculux TC420L-827-S-U  Recessed Lighting  3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 2700K Color Temp, 80 CRI, Spot Beam, 120-277V, 0-10V Dimming, 10%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481100771635,"sku":"Juno-TC420L-827-S-U","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-827-S-U-2.jpg?v=1690035698"},{"product_id":"juno-tc420l-827-w-1","title":"Juno Aculux Recessed Lighting TC420L-827-W-1 (AX3 A 20LM 27K 80CRI 50D FPC 120) 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Wide Flood Beam, 120V, Forward \u0026 Reverse Phase Dimming, 5%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481100968243,"sku":"Juno-TC420L-827-W-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-827-W-1-2.jpg?v=1690035710"},{"product_id":"juno-tc420l-827-w-d","title":"Juno Aculux Recessed Lighting TC420L-827-W-D (AX3 A 20LM 27K 80CRI 50D ECOS2 120) 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Wide Flood Beam, 120V, Lutron Hi-Lume 2-Wire Dimming, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481101328691,"sku":"Juno-TC420L-827-W-D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-827-W-D-2.jpg?v=1690035721"},{"product_id":"juno-tc420l-827-w-l","title":"Juno Aculux Recessed Lighting TC420L-827-W-L 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 2700K Color Temperature, 80 CRI, Wide Flood Beam, 120-277V, Lutron Hi-Lume 3-Wire Dimming, Ecosystem Compatible, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481101525299,"sku":"Juno-TC420L-827-W-L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-827-W-L-2_1e20e148-c1c8-4ea2-8cde-9f4cea513711.jpg?v=1690035732"},{"product_id":"juno-tc420l-827-w-u","title":"Juno Aculux TC420L-827-W-U  Recessed Lighting  3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 2700K Color Temp, 80 CRI, Wide Flood Beam, 120-277V, 0-10V Dimming, 10%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481102147891,"sku":"Juno-TC420L-827-W-U","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-827-W-U-2.jpg?v=1690035745"},{"product_id":"juno-tc420l-830-f-1","title":"Juno Aculux Recessed Lighting TC420L-830-F-1 (AX3 A 20LM 30K 80CRI 35D FPC 120) 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Flood Beam, 120V, Forward \u0026 Reverse Phase Dimming, 5%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481103098163,"sku":"Juno-TC420L-830-F-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-830-F-1-2.jpg?v=1690035756"},{"product_id":"juno-tc420l-830-f-d","title":"Juno Aculux Recessed Lighting TC420L-830-F-D (AX3 A 20LM 30K 80CRI 35D ECOS2 120) 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Flood Beam, 120V, Lutron Hi-Lume 2-Wire Dimming, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481103425843,"sku":"Juno-TC420L-830-F-D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-830-F-D-2_ff011fe2-f895-4ebe-a7f3-35e7f38cba46.jpg?v=1690035767"},{"product_id":"juno-tc420l-830-f-l","title":"Juno Aculux Recessed Lighting TC420L-830-F-L 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Flood Beam, 120-277V, Lutron Hi-Lume 3-Wire Dimming, Ecosystem Compatible, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481103589683,"sku":"Juno-TC420L-830-F-L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-830-F-L-2.jpg?v=1690035778"},{"product_id":"juno-tc420l-830-f-u","title":"Juno Aculux TC420L-830-F-U  Recessed Lighting  3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 3000K Color Temp, 80 CRI, Flood Beam, 120-277V, 0-10V Dimming, 10%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481103982899,"sku":"Juno-TC420L-830-F-U","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-830-F-U-2_27c34b9b-5d93-4d91-a15f-141c218b5279.jpg?v=1690035789"},{"product_id":"juno-tc420l-830-n-1","title":"Juno Aculux Recessed Lighting TC420L-830-N-1 (AX3 A 20LM 30K 80CRI 24D FPC 120) 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Narrow Flood Beam, 120V, Forward \u0026 Reverse Phase Dimming, 5%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481104113971,"sku":"Juno-TC420L-830-N-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-830-N-1-2.jpg?v=1690035802"},{"product_id":"juno-tc420l-830-n-d","title":"Juno Aculux Recessed Lighting TC420L-830-N-D (AX3 A 20LM 30K 80CRI 24D ECOS2 120) 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Narrow Flood Beam, 120V, Lutron Hi-Lume 2-Wire Dimming, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481104310579,"sku":"Juno-TC420L-830-N-D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-830-N-D-2.jpg?v=1690035813"},{"product_id":"juno-tc420l-830-n-l","title":"Juno Aculux Recessed Lighting TC420L-830-N-L 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Narrow Flood Beam, 120-277V, Lutron Hi-Lume 3-Wire Dimming, Ecosystem Compatible, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481104507187,"sku":"Juno-TC420L-830-N-L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-830-N-L-2.jpg?v=1690035824"},{"product_id":"juno-tc420l-830-n-u","title":"Juno Aculux TC420L-830-N-U  Recessed Lighting  3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 3000K Color Temp, 80 CRI, Narrow Flood Beam, 120-277V, 0-10V Dimming, 10%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481104933171,"sku":"Juno-TC420L-830-N-U","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-830-N-U-2.jpg?v=1690035835"},{"product_id":"juno-tc420l-830-s-1","title":"Juno Aculux Recessed Lighting TC420L-830-S-1 (AX3 A 20LM 30K 80CRI 12D FPC 120) 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Spot Beam, 120V, Forward \u0026 Reverse Phase Dimming, 5%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481105097011,"sku":"Juno-TC420L-830-S-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-830-S-1-2_3461e416-a089-43fe-8b40-c613cb078a03.jpg?v=1690035846"},{"product_id":"juno-tc420l-830-s-d","title":"Juno Aculux Recessed Lighting TC420L-830-S-D (AX3 A 20LM 30K 80CRI 12D ECOS2 120) 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Spot Beam, 120V, Lutron Hi-Lume 2-Wire Dimming, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481105457459,"sku":"Juno-TC420L-830-S-D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-830-S-D-2.jpg?v=1690035857"},{"product_id":"juno-tc420l-830-s-l","title":"Juno Aculux Recessed Lighting TC420L-830-S-L 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Spot Beam, 120-277V, Lutron Hi-Lume 3-Wire Dimming, Ecosystem Compatible, 1%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481105686835,"sku":"Juno-TC420L-830-S-L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-830-S-L-2.jpg?v=1690035868"},{"product_id":"juno-tc420l-830-s-u","title":"Juno Aculux TC420L-830-S-U  Recessed Lighting  3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 3000K Color Temp, 80 CRI, Spot Beam, 120-277V, 0-10V Dimming, 10%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481106276659,"sku":"Juno-TC420L-830-S-U","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-830-S-U-2.jpg?v=1690035880"},{"product_id":"juno-tc420l-830-w-1","title":"Juno Aculux Recessed Lighting TC420L-830-W-1 (AX3 A 20LM 30K 80CRI 50D FPC 120) 3-1\/4 inch LED New Construction Adjustable Non-IC Housing, 2000 Lumens, 3000K Color Temperature, 80 CRI, Wide Flood Beam, 120V, Forward \u0026 Reverse Phase Dimming, 5%","description":"\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctitle\u003eUntitled Document\u003c\/title\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecessed adjustable LED luminaire produces up to 2000 delivered lumens. Depending on the optic, the fixture has up to 50° visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum energy savings and controls plenum sound transmission. Non-IC luminaires must be used in non-insulated areas or where insulation is spaced at least 3” from housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent fixture to fixture color within 3-step MacAdam ellipse\u003c\/li\u003e\n  \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n  \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModular Optics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n  \u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of the diffusing films and spot primary optic\u003c\/li\u003e\n  \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic holder maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n  \u003cli\u003eAccommodates up to three (3) additional beam control lenses and\/or filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, 45° tilt\u003c\/li\u003e\n  \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n  \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Style\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck PDF spec for trims selection\u003c\/li\u003e\n  \u003cli\u003eTrim Ring, Self Flanged and Flush Mount reflectors utilize torsion spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n  \u003cli\u003eTrim ring features beveled knife edge for clean ceiling interface\u003c\/li\u003e\n  \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA4 flush mount adapter\u003c\/li\u003e\n  \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA4-SC*** must be used (specify ceiling thickness and adapter finish).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLED Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eChoice of six drivers to accommodate voltages from 120-277 volts AC\u003c\/li\u003e\n  \u003cli\u003eDedicated 120V (-1) driver is dimmable with most incandescent, magnetic low voltage, and electronic low voltage dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Universal Voltage (-U) driver is dimmable with most 0-10V protocol dimmers\u003c\/li\u003e\n  \u003cli\u003e120-277V Lutron Hi-Lume A Series 3-wire (-L) driver is dimmable with 3-wire fluorescent controls and compatible with EcoSystem\u003c\/li\u003e\n  \u003cli\u003e120V Lutron Hi-Lume A Series 2-wire (-D) driver is dimmable with 2-wire forward phase dimmers containing a neutral wire\u003c\/li\u003e\n  \u003cli\u003e120-277V DALI Compatible Driver (-A)\u003c\/li\u003e\n  \u003cli\u003e120-277V DMX512 drivers are available with Flying Leads (-M) or RJ45 Interface Board (-MRJ). Note: DMX data cables must be run in series between fixtures and a DMX termination device (by others) should be used on last fixture in line\u003c\/li\u003e\n  \u003cli\u003eFor a list of compatible dimmers, refer to \u003ca href=\"\/Juno-Aculux-Gen-3-LED-Adjustable-Downlight-Dimmer-s\/6712.htm\"\u003eACLXLED3-DIM\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n  \u003cli\u003eField replaceable from below or above ceiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLife\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRated for 50,000 hrs at 70% lumen maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e5 years from date of purchase on LED components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCodes and Labels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n  \u003cli\u003eMeets energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n  \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n  \u003cli\u003eIC housings are rated for direct contact with insulation\u003c\/li\u003e\n  \u003cli\u003eIC408L and IC412L are compatible with spray foam insulation with an R-Value of 3.7 per inch or less\u003c\/li\u003e\n  \u003cli\u003eUnion made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e Housing, trim and accessories each ordered separately\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC408L-IC412L-IC415L-IC420L-TC420L-ordering-information_49e240f0-3184-4f6a-a7d5-9e5594eb143a.jpg?v=1761993135\"\u003e\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481106342195,"sku":"Juno-TC420L-830-W-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC420L-830-W-1-2.jpg?v=1690035891"}],"url":"https:\/\/electricbargainstores.com\/collections\/juno-aculux-recessed-lighting-tc420l-3-1-4-inch-led-housings.oembed?page=3","provider":"Electric Bargain Store","version":"1.0","type":"link"}