{"title":"Juno Aculux Recessed Lighting TC532L 4 inch Adjustable LED Housings","description":"","products":[{"product_id":"juno-ax4-a-6753","title":"Juno Aculux AX4 A 32LM 27K 80CRI 12D DALI MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 2700K Color, 12 Degree Spot, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462914892083,"sku":"Juno-AX4-A-6753","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6753-2_56668bc4-4693-4c47-a4d6-32b5a614c81e.jpg?v=1689649792"},{"product_id":"juno-ax4-a-6754","title":"Juno Aculux AX4 A 32LM 27K 80CRI 12D DMXR MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 2700K Color, 12 Degree Spot, DMX,RDM Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462915088691,"sku":"Juno-AX4-A-6754","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6754-2.jpg?v=1689649802"},{"product_id":"juno-ax4-a-6755","title":"Juno Aculux AX4 A 32LM 27K 80CRI 12D ECOS2 120 Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 2700K Color, 12 Degree Spot, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462915186995,"sku":"Juno-AX4-A-6755","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6755-2_4cf09ef8-a8be-4974-8b7b-15b11e89a2f2.jpg?v=1689649812"},{"product_id":"juno-ax4-a-6756","title":"Juno Aculux AX4 A 32LM 27K 80CRI 12D ECOS3 MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 2700K Color, 12 Degree Spot, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462915744051,"sku":"Juno-AX4-A-6756","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6756-2_0441a604-669b-418f-bd7c-ff443f7aeee6.jpg?v=1689649822"},{"product_id":"juno-ax4-a-6759","title":"Juno Aculux AX4 A 32LM 27K 80CRI 12D EZ1 MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 2700K Color, 12 Degree Spot, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462920888627,"sku":"Juno-AX4-A-6759","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6759-2_ff01ec63-d115-445f-b0e2-4537ab40b9b3.jpg?v=1689649853"},{"product_id":"juno-ax4-a-6762","title":"Juno Aculux AX4 A 32LM 27K 80CRI 12D EZB MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 2700K Color, 12 Degree Spot, eldoLED 0-10V, \u003c1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462933766451,"sku":"Juno-AX4-A-6762","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6762-2.jpg?v=1689649883"},{"product_id":"juno-ax4-a-6763","title":"Juno Aculux AX4 A 32LM 27K 80CRI 12D FPC 120 Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 2700K Color, 12 Degree Spot, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462937010483,"sku":"Juno-AX4-A-6763","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6763-2_c121d47e-46a4-42c0-ab54-7aedacbe34a2.jpg?v=1689649893"},{"product_id":"juno-ax4-a-6766","title":"Juno Aculux AX4 A 32LM 27K 80CRI 35D EZ1 MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 2700K Color, 35 Degree Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462947168563,"sku":"Juno-AX4-A-6766","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6766-2_cca04cc4-fcdd-4188-84d0-e22b26fb43c3.jpg?v=1689649922"},{"product_id":"juno-ax4-a-6769","title":"Juno Aculux AX4 A 32LM 27K 90CRI 24D DALI MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 2700K Color, 24 Degree Narrow Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462948380979,"sku":"Juno-AX4-A-6769","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6769-2_90fcf819-1a0d-4bd3-b5db-451c8fb95f91.jpg?v=1689650079"},{"product_id":"juno-ax4-a-6770","title":"Juno Aculux AX4 A 32LM 27K 90CRI 24D DMXR MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 2700K Color, 24 Degree Narrow Flood, DMX,RDM Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462948479283,"sku":"Juno-AX4-A-6770","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6770-2.jpg?v=1689650090"},{"product_id":"juno-ax4-a-6771","title":"Juno Aculux AX4 A 32LM 27K 90CRI 24D ECOS2 120 Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 2700K Color, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462948610355,"sku":"Juno-AX4-A-6771","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6771-2_73f8a915-9e4a-42bd-a993-86beaab26efb.jpg?v=1689650099"},{"product_id":"juno-ax4-a-6772","title":"Juno Aculux AX4 A 32LM 27K 90CRI 24D ECOS3 MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 2700K Color, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462949003571,"sku":"Juno-AX4-A-6772","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6772-2_92cdf26e-70d2-445d-a828-04b5efa3ae57.jpg?v=1689650109"},{"product_id":"juno-ax4-a-6775","title":"Juno Aculux AX4 A 32LM 27K 90CRI 24D EZ1 MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 2700K Color, 24 Degree Narrow Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462952182067,"sku":"Juno-AX4-A-6775","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6775-2_abb5cd4d-48fa-4244-8a62-d1eeb0f3c036.jpg?v=1689650140"},{"product_id":"juno-ax4-a-6778","title":"Juno Aculux AX4 A 32LM 27K 90CRI 24D EZB MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 2700K Color, 24 Degree Narrow Flood, eldoLED 0-10V, \u003c1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462953886003,"sku":"Juno-AX4-A-6778","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6778-2_5b830f47-7be4-4565-91c8-761914eefa7d.jpg?v=1689650170"},{"product_id":"juno-ax4-a-6779","title":"Juno Aculux AX4 A 32LM 27K 90CRI 24D FPC 120 Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 2700K Color, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462954017075,"sku":"Juno-AX4-A-6779","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6779-2.jpg?v=1689650180"},{"product_id":"juno-ax4-a-6780","title":"Juno Aculux AX4 A 32LM 30K 80CRI 24D DALI MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3000K Color, 24 Degree Narrow Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462954344755,"sku":"Juno-AX4-A-6780","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6780-2_7dedc63a-5b4f-4623-9a25-65abf8694856.jpg?v=1689650190"},{"product_id":"juno-ax4-a-6781","title":"Juno Aculux AX4 A 32LM 30K 80CRI 24D DMXR MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3000K Color, 24 Degree Narrow Flood, DMX,RDM Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462954508595,"sku":"Juno-AX4-A-6781","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6781-2.jpg?v=1689650200"},{"product_id":"juno-ax4-a-6782","title":"Juno Aculux AX4 A 32LM 30K 80CRI 24D ECOS2 120 Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3000K Color, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462956998963,"sku":"Juno-AX4-A-6782","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6782-2.jpg?v=1689650210"},{"product_id":"juno-ax4-a-6783","title":"Juno Aculux AX4 A 32LM 30K 80CRI 24D ECOS3 MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3000K Color, 24 Degree Narrow Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462957130035,"sku":"Juno-AX4-A-6783","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6783-2.jpg?v=1689650221"},{"product_id":"juno-ax4-a-6786","title":"Juno Aculux AX4 A 32LM 30K 80CRI 24D EZ1 MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3000K Color, 24 Degree Narrow Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462958113075,"sku":"Juno-AX4-A-6786","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6786-2.jpg?v=1689650251"},{"product_id":"juno-ax4-a-6789","title":"Juno Aculux AX4 A 32LM 30K 80CRI 24D EZB MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3000K Color, 24 Degree Narrow Flood, eldoLED 0-10V, \u003c1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462958670131,"sku":"Juno-AX4-A-6789","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6789-2.jpg?v=1689650283"},{"product_id":"juno-ax4-a-6790","title":"Juno Aculux AX4 A 32LM 30K 80CRI 24D FPC 120 Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3000K Color, 24 Degree Narrow Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462958965043,"sku":"Juno-AX4-A-6790","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6790-2_5fe29d3d-8fcd-4a3a-b643-a816a8d07a62.jpg?v=1689650294"},{"product_id":"juno-ax4-a-6791","title":"Juno Aculux AX4 A 32LM 30K 90CRI 35D DALI MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3000K Color, 35 Degree Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462959227187,"sku":"Juno-AX4-A-6791","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6791-2.jpg?v=1689650304"},{"product_id":"juno-ax4-a-6792","title":"Juno Aculux AX4 A 32LM 30K 90CRI 35D DMXR MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3000K Color, 35 Degree Flood, DMX,RDM Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462959358259,"sku":"Juno-AX4-A-6792","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6792-2.jpg?v=1689650314"},{"product_id":"juno-ax4-a-6793","title":"Juno Aculux AX4 A 32LM 30K 90CRI 35D ECOS2 120 Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3000K Color, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462959554867,"sku":"Juno-AX4-A-6793","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6793-2_a475d359-cd87-4a18-8400-6e6ca9d971bf.jpg?v=1689650324"},{"product_id":"juno-ax4-a-6794","title":"Juno Aculux AX4 A 32LM 30K 90CRI 35D ECOS3 MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3000K Color, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462959784243,"sku":"Juno-AX4-A-6794","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6794-2.jpg?v=1689650335"},{"product_id":"juno-ax4-a-6797","title":"Juno Aculux AX4 A 32LM 30K 90CRI 35D EZ1 MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3000K Color, 35 Degree Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462960865587,"sku":"Juno-AX4-A-6797","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6797-2_e7fd7615-bc0e-43f0-9216-91c3c119c1ed.jpg?v=1689650364"},{"product_id":"juno-ax4-a-6800","title":"Juno Aculux AX4 A 32LM 30K 90CRI 35D EZB MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3000K Color, 35 Degree Flood, eldoLED 0-10V, \u003c1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462963192115,"sku":"Juno-AX4-A-6800","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Juno-AX4-A-6800-2.jpg?v=1726537895"},{"product_id":"juno-ax4-a-6801","title":"Juno Aculux AX4 A 32LM 30K 90CRI 35D FPC 120 Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3000K Color, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462964535603,"sku":"Juno-AX4-A-6801","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6801-2_fcf29671-5031-4ef7-93c5-18dadacf3da6.jpg?v=1689650409"},{"product_id":"juno-ax4-a-6803","title":"Juno Aculux AX4 A 32LM 35K 80CRI 24D EZ1 MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3500K Color, 24 Degree Narrow Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462965027123,"sku":"Juno-AX4-A-6803","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6803-2.jpg?v=1689650429"},{"product_id":"juno-ax4-a-6804","title":"Juno Aculux AX4 A 32LM 35K 80CRI 35D DALI MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3500K Color, 35 Degree Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462967058739,"sku":"Juno-AX4-A-6804","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6804-2.jpg?v=1689650439"},{"product_id":"juno-ax4-a-6805","title":"Juno Aculux AX4 A 32LM 35K 80CRI 35D DMXR MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3500K Color, 35 Degree Flood, DMX,RDM Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462967222579,"sku":"Juno-AX4-A-6805","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6805-2_87d046b3-e10a-4bae-bf96-359a94a4d357.jpg?v=1689650449"},{"product_id":"juno-ax4-a-6806","title":"Juno Aculux AX4 A 32LM 35K 80CRI 35D ECOS2 120 Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3500K Color, 35 Degree Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462967451955,"sku":"Juno-AX4-A-6806","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6806-2_7d5c5d5e-076a-4209-bf2c-7951a66f27b0.jpg?v=1689650459"},{"product_id":"juno-ax4-a-6807","title":"Juno Aculux AX4 A 32LM 35K 80CRI 35D ECOS3 MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3500K Color, 35 Degree Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462967681331,"sku":"Juno-AX4-A-6807","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6807-2.jpg?v=1689650469"},{"product_id":"juno-ax4-a-6810","title":"Juno Aculux AX4 A 32LM 35K 80CRI 35D EZ1 MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3500K Color, 35 Degree Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462969647411,"sku":"Juno-AX4-A-6810","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6810-2_43f97d84-3a10-459d-a3f5-5ffe425ac29b.jpg?v=1689650498"},{"product_id":"juno-ax4-a-6813","title":"Juno Aculux AX4 A 32LM 35K 80CRI 35D EZB MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3500K Color, 35 Degree Flood, eldoLED 0-10V, \u003c1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462971515187,"sku":"Juno-AX4-A-6813","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6813-2_c2c2b9bd-19e1-495a-8459-091e7d6abbe8.jpg?v=1689650527"},{"product_id":"juno-ax4-a-6814","title":"Juno Aculux AX4 A 32LM 35K 80CRI 35D FPC 120 Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 3500K Color, 35 Degree Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462973382963,"sku":"Juno-AX4-A-6814","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6814-2.jpg?v=1689650537"},{"product_id":"juno-ax4-a-6815","title":"Juno Aculux AX4 A 32LM 40K 80CRI 35D EZ1 MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 4000K Color, 35 Degree Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462973481267,"sku":"Juno-AX4-A-6815","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6815-2.jpg?v=1689650547"},{"product_id":"juno-ax4-a-6816","title":"Juno Aculux AX4 A 32LM 40K 80CRI 50D DALI MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 4000K Color, 50 Degree Wide Flood, DALI Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462973612339,"sku":"Juno-AX4-A-6816","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6816-2_4d5ab3d2-b706-45a8-b8dd-45a32785c4fe.jpg?v=1689650556"},{"product_id":"juno-ax4-a-6817","title":"Juno Aculux AX4 A 32LM 40K 80CRI 50D DMXR MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 4000K Color, 50 Degree Wide Flood, DMX,RDM Driver, 1% Dim, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462975316275,"sku":"Juno-AX4-A-6817","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6817-2.jpg?v=1689650566"},{"product_id":"juno-ax4-a-6818","title":"Juno Aculux AX4 A 32LM 40K 80CRI 50D ECOS2 120 Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 4000K Color, 50 Degree Wide Flood, Lutron Hi-Lume A Series 2-Wire, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462976758067,"sku":"Juno-AX4-A-6818","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6818-2_6420e9f4-309d-466d-9450-e11dbf37906f.jpg?v=1689650576"},{"product_id":"juno-ax4-a-6819","title":"Juno Aculux AX4 A 32LM 40K 80CRI 50D ECOS3 MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 4000K Color, 50 Degree Wide Flood, Lutron Hi-Lume A Series 3-Wire, 120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462977610035,"sku":"Juno-AX4-A-6819","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6819-2_8de8ae18-cce1-45f1-a58b-ce42c91c0a19.jpg?v=1689650586"},{"product_id":"juno-ax4-a-6822","title":"Juno Aculux AX4 A 32LM 40K 80CRI 50D EZ1 MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 4000K Color, 50 Degree Wide Flood, eldoLED 0-10V, 1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462979641651,"sku":"Juno-AX4-A-6822","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6822-2_a1aeafbb-403a-439d-806c-3c22d537ecca.jpg?v=1689650615"},{"product_id":"juno-ax4-a-6825","title":"Juno Aculux AX4 A 32LM 40K 80CRI 50D EZB MVOLT Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 4000K Color, 50 Degree Wide Flood, eldoLED 0-10V, \u003c1% Dim120-277V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462980591923,"sku":"Juno-AX4-A-6825","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6825-2.jpg?v=1689650644"},{"product_id":"juno-ax4-a-6826","title":"Juno Aculux AX4 A 32LM 40K 80CRI 50D FPC 120 Recessed Lighting 4 inch IC LED New Construction Adjustable Housing, 3200 Lumens, 4000K Color, 50 Degree Wide Flood, Phase Cut Dimming, 5% Dim, 120V","description":"\u003cp\u003e\n \u003cstrong style=\"background-color: initial; letter-spacing: 0px;\"\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n \u003c\/li\u003e\n \u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n \u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAvailable with 12 degree Spot, 24 degree Narrow Flood, 35 degree Flood and 50 degree wide flood field interchangeable optics\u003c\/li\u003e\n \u003cli\u003eAdditional distributions of 20 degree, 30 degree, 40 degree, 45 degree and 60 degree FWHM can be achieved with the use of diffusing films and spot primary optic\u003c\/li\u003e\n \u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n \u003cli\u003eAccommodates up to two (2) additional 0.156\" thick or (3) 0.125\" thick beam control lenses and\/or filters.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eAcu-Aim precision geared hot-aiming achieves 370 degree rotation, and up to 45 degree tilt (depending on trim and ceiling thickness)\u003c\/li\u003e\n \u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n \u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n \u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n \u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness and adapter finish).\u003cbr\u003e\n \u003c\/li\u003e\n \u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n \u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n \u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n \u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n \u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n \u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n \u003cli\u003eENERGY STAR Qualified with select trims\u003c\/li\u003e\n \u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and trims\u003c\/li\u003e\n \u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or lesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n \u003cli\u003eUnion made.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI bar hanger system, permitting quick placement of housing with 24\" on-center joists or suspended ceilings\u003c\/li\u003e\n \u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n \u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line Platform featuring +\/- 1\/2\" translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90 degree C through branch circuit conductors and includes (6) 1\/2\", (1) 3\/4\", and (4) Non-metallic sheathed cable knock-outs\n \u003c\/li\u003e\n \u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e1\/2\" - 7\/8\" ceiling standard\u003c\/li\u003e\n \u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8\"-1 1\/4\"), CTA5-163 (1 1\/4\"- 1 5\/8\") or CTA5-200 (1 5\/8\" - 2\")\u003c\/li\u003e\n \u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/juno-AX4-A-ordering-information_8b1687f2-9e0d-495c-8480-6d29c6ad88d1.jpg?v=1761976761\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45462980690227,"sku":"Juno-AX4-A-6826","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-AX4-A-6826-2_6a0480da-dc9a-4592-ba2f-7bc1a8332f86.jpg?v=1689650654"},{"product_id":"juno-tc532l-827-f-1","title":"Juno Aculux TC532L-827-F-1  Recessed Lighting 4 inch LED New Construction Round Adjustable IC Housing, 3200 Lumens, 2700K Color Temp, 80 CRI, Flood Beam, 120, Forward \u0026 Revese Phase Dimming, 5%","description":"\u003cp\u003e\n\t\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n\tRound recessed universal adjustable, downlight and wall wash\n  LED luminaire produces up to 3200 delivered lumens. Fixture\n  has 45° visual cutoff and features precision geared hot-aiming.\n  Available in both IC and Non-IC rated configurations. IC rated\n  luminaires are Air-Loc rated to ensure maximum energy savings\n  and controls plenum sound transmission.\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n\t\u003c\/li\u003e\n\t\u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n\t\u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n\t\u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of diffusing films and spot primary\u003cbr\u003e\n\toptic\u003c\/li\u003e\n\t\u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n\t\u003cli\u003eAccommodates up to two (2) additional 0.156” thick or (3) 0.125” thick beam control lenses and\/or filters.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, and up to 45° tilt (depending on trim and ceiling\u003cbr\u003e\n\tthickness)\u003c\/li\u003e\n\t\u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n\t\u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n\t\u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n\t\u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n\t\u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness\u003cbr\u003e\n\tand adapter finish).\u003cbr\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n\t\u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n\t\u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n\t\u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n\t\u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n\t\u003cli\u003eENERGY STAR® Qualified with select trims\u003c\/li\u003e\n\t\u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and\u003cbr\u003e\n\ttrims\u003c\/li\u003e\n\t\u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or\u003cbr\u003e\n\tlesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n\t\u003cli\u003eUnion made.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI™ bar hanger system, permitting quick placement of housing with 24” on-center joists or suspended ceilings\u003c\/li\u003e\n\t\u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n\t\u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line™ Platform featuring +\/- ½” translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90° C through branch circuit conductors and includes (6) ½”, (1) ¾”, and (4) Non-metallic sheathed cable knock-outs\n\t\u003c\/li\u003e\n\t\u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003e1\/2” – 7\/8” ceiling standard\u003c\/li\u003e\n\t\u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8”-1 1\/4”), CTA5-163 (1 1\/4”- 1 5\/8”) or CTA5-200 (1 5\/8”– 2”)\u003c\/li\u003e\n\t\u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eORDERING INFORMATION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n\t \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC512L-IC517L-IC522L-IC527L-TC532L-ordering-information_36380e45-50f1-48ee-8a94-2c8b414decb1.jpg?v=1762042487\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481536422195,"sku":"Juno-TC532L-827-F-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC532L-827-F-1-2.jpg?v=1690043898"},{"product_id":"juno-tc532l-827-f-a","title":"Juno Aculux TC532L-827-F-A  Recessed Lighting 4 inch LED New Construction Round Adjustable IC Housing, 3200 Lumens, 2700K Color Temp, 80 CRI, Flood Beam, 120-277V, DALI Dimming","description":"\u003cp\u003e\n\t\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n\tRound recessed universal adjustable, downlight and wall wash\n  LED luminaire produces up to 3200 delivered lumens. Fixture\n  has 45° visual cutoff and features precision geared hot-aiming.\n  Available in both IC and Non-IC rated configurations. IC rated\n  luminaires are Air-Loc rated to ensure maximum energy savings\n  and controls plenum sound transmission.\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n\t\u003c\/li\u003e\n\t\u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n\t\u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n\t\u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of diffusing films and spot primary\u003cbr\u003e\n\toptic\u003c\/li\u003e\n\t\u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n\t\u003cli\u003eAccommodates up to two (2) additional 0.156” thick or (3) 0.125” thick beam control lenses and\/or filters.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, and up to 45° tilt (depending on trim and ceiling\u003cbr\u003e\n\tthickness)\u003c\/li\u003e\n\t\u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n\t\u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n\t\u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n\t\u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n\t\u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness\u003cbr\u003e\n\tand adapter finish).\u003cbr\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n\t\u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n\t\u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n\t\u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n\t\u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n\t\u003cli\u003eENERGY STAR® Qualified with select trims\u003c\/li\u003e\n\t\u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and\u003cbr\u003e\n\ttrims\u003c\/li\u003e\n\t\u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or\u003cbr\u003e\n\tlesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n\t\u003cli\u003eUnion made.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI™ bar hanger system, permitting quick placement of housing with 24” on-center joists or suspended ceilings\u003c\/li\u003e\n\t\u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n\t\u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line™ Platform featuring +\/- ½” translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90° C through branch circuit conductors and includes (6) ½”, (1) ¾”, and (4) Non-metallic sheathed cable knock-outs\n\t\u003c\/li\u003e\n\t\u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003e1\/2” – 7\/8” ceiling standard\u003c\/li\u003e\n\t\u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8”-1 1\/4”), CTA5-163 (1 1\/4”- 1 5\/8”) or CTA5-200 (1 5\/8”– 2”)\u003c\/li\u003e\n\t\u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eORDERING INFORMATION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n\t \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC512L-IC517L-IC522L-IC527L-TC532L-ordering-information_36380e45-50f1-48ee-8a94-2c8b414decb1.jpg?v=1762042487\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481537765683,"sku":"Juno-TC532L-827-F-A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC532L-827-F-A-2.jpg?v=1690043909"},{"product_id":"juno-tc532l-827-f-d","title":"Juno Aculux TC532L-827-F-D  Recessed Lighting 4 inch LED New Construction Round Adjustable IC Housing, 3200 Lumens, 2700K Color Temp, 80 CRI, Flood Beam, 120V, Lutron Hi-Lume 2-Wire Dimming, 1%","description":"\u003cp\u003e\n\t\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n\tRound recessed universal adjustable, downlight and wall wash\n  LED luminaire produces up to 3200 delivered lumens. Fixture\n  has 45° visual cutoff and features precision geared hot-aiming.\n  Available in both IC and Non-IC rated configurations. IC rated\n  luminaires are Air-Loc rated to ensure maximum energy savings\n  and controls plenum sound transmission.\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n\t\u003c\/li\u003e\n\t\u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n\t\u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n\t\u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of diffusing films and spot primary\u003cbr\u003e\n\toptic\u003c\/li\u003e\n\t\u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n\t\u003cli\u003eAccommodates up to two (2) additional 0.156” thick or (3) 0.125” thick beam control lenses and\/or filters.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, and up to 45° tilt (depending on trim and ceiling\u003cbr\u003e\n\tthickness)\u003c\/li\u003e\n\t\u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n\t\u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n\t\u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n\t\u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n\t\u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness\u003cbr\u003e\n\tand adapter finish).\u003cbr\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n\t\u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n\t\u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n\t\u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n\t\u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n\t\u003cli\u003eENERGY STAR® Qualified with select trims\u003c\/li\u003e\n\t\u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and\u003cbr\u003e\n\ttrims\u003c\/li\u003e\n\t\u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or\u003cbr\u003e\n\tlesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n\t\u003cli\u003eUnion made.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI™ bar hanger system, permitting quick placement of housing with 24” on-center joists or suspended ceilings\u003c\/li\u003e\n\t\u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n\t\u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line™ Platform featuring +\/- ½” translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90° C through branch circuit conductors and includes (6) ½”, (1) ¾”, and (4) Non-metallic sheathed cable knock-outs\n\t\u003c\/li\u003e\n\t\u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003e1\/2” – 7\/8” ceiling standard\u003c\/li\u003e\n\t\u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8”-1 1\/4”), CTA5-163 (1 1\/4”- 1 5\/8”) or CTA5-200 (1 5\/8”– 2”)\u003c\/li\u003e\n\t\u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eORDERING INFORMATION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n\t \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC512L-IC517L-IC522L-IC527L-TC532L-ordering-information_36380e45-50f1-48ee-8a94-2c8b414decb1.jpg?v=1762042487\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481537929523,"sku":"Juno-TC532L-827-F-D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC532L-827-F-D-2.jpg?v=1690043920"},{"product_id":"juno-tc532l-827-f-ez1","title":"Juno Aculux Recessed Lighting TC532L-827-F-EZ1 (AX4 A 32LM 27K 80CRI 35D EZ1 MVOLT) 4 inch LED New Construction Round Adjustable IC Housing, 3200 Lumens, 2700K Color Temperature, 80 CRI, Flood Beam, 120-277V, eldoLED ECOdrive 0-10V Dimming, 1%","description":"\u003cp\u003e\n\t\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n\tRound recessed universal adjustable, downlight and wall wash\n  LED luminaire produces up to 3200 delivered lumens. Fixture\n  has 45° visual cutoff and features precision geared hot-aiming.\n  Available in both IC and Non-IC rated configurations. IC rated\n  luminaires are Air-Loc rated to ensure maximum energy savings\n  and controls plenum sound transmission.\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n\t\u003c\/li\u003e\n\t\u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n\t\u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n\t\u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of diffusing films and spot primary\u003cbr\u003e\n\toptic\u003c\/li\u003e\n\t\u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n\t\u003cli\u003eAccommodates up to two (2) additional 0.156” thick or (3) 0.125” thick beam control lenses and\/or filters.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, and up to 45° tilt (depending on trim and ceiling\u003cbr\u003e\n\tthickness)\u003c\/li\u003e\n\t\u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n\t\u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n\t\u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n\t\u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n\t\u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness\u003cbr\u003e\n\tand adapter finish).\u003cbr\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n\t\u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n\t\u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n\t\u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n\t\u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n\t\u003cli\u003eENERGY STAR® Qualified with select trims\u003c\/li\u003e\n\t\u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and\u003cbr\u003e\n\ttrims\u003c\/li\u003e\n\t\u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or\u003cbr\u003e\n\tlesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n\t\u003cli\u003eUnion made.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI™ bar hanger system, permitting quick placement of housing with 24” on-center joists or suspended ceilings\u003c\/li\u003e\n\t\u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n\t\u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line™ Platform featuring +\/- ½” translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90° C through branch circuit conductors and includes (6) ½”, (1) ¾”, and (4) Non-metallic sheathed cable knock-outs\n\t\u003c\/li\u003e\n\t\u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003e1\/2” – 7\/8” ceiling standard\u003c\/li\u003e\n\t\u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8”-1 1\/4”), CTA5-163 (1 1\/4”- 1 5\/8”) or CTA5-200 (1 5\/8”– 2”)\u003c\/li\u003e\n\t\u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eORDERING INFORMATION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n\t \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC512L-IC517L-IC522L-IC527L-TC532L-ordering-information_36380e45-50f1-48ee-8a94-2c8b414decb1.jpg?v=1762042487\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481539698995,"sku":"Juno-TC532L-827-F-EZ1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC532L-827-F-EZ1-2.jpg?v=1690043932"},{"product_id":"juno-tc532l-827-f-ezb","title":"Juno Aculux TC532L-827-F-EZB  Recessed Lighting 4 inch LED New Construction Round Adjustable IC Housing, 3200 Lumens, 2700K Color Temp, 80 CRI, Flood Beam, 120-277V, eldoLED SOLOdrive 0-10V Dimming, \u003c1%","description":"\u003cp\u003e\n\t\u003cstrong\u003ePRODUCT DESCRIPTION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n\tRound recessed universal adjustable, downlight and wall wash\n  LED luminaire produces up to 3200 delivered lumens. Fixture\n  has 45° visual cutoff and features precision geared hot-aiming.\n  Available in both IC and Non-IC rated configurations. IC rated\n  luminaires are Air-Loc rated to ensure maximum energy savings\n  and controls plenum sound transmission.\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003ePRODUCT SPECIFCATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eLED Light Engine\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eConsistent fixture to fixture color within 3-step \n  MacAdam ellipse\n\t\u003c\/li\u003e\n\t\u003cli\u003e2700K, 3000K, 3500K, or 4000K color temperatures are available with 80 CRI minimum\u003c\/li\u003e\n\t\u003cli\u003e2700K and 3000K also available with 90 CRI minimum.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eModular Optics\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eAvailable with 12° Spot, 24° Narrow Flood, 35° Flood and 50° wide flood field interchangeable optics\u003c\/li\u003e\n\t\u003cli\u003eAdditional distributions of 20°, 30°, 40°, 45° and 60° FWHM can be achieved with the use of diffusing films and spot primary\u003cbr\u003e\n\toptic\u003c\/li\u003e\n\t\u003cli\u003ePatented (US Patent 8,950,911) auto-adjusting optic older maximizes luminaire efficiency by maintaining optimal LED optic position\u003c\/li\u003e\n\t\u003cli\u003eAccommodates up to two (2) additional 0.156” thick or (3) 0.125” thick beam control lenses and\/or filters.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eAdjustability\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eAcu-Aim™ precision geared hot-aiming achieves 370° rotation, and up to 45° tilt (depending on trim and ceiling\u003cbr\u003e\n\tthickness)\u003c\/li\u003e\n\t\u003cli\u003eOptimized center beam optics translates light engine forward as it is aimed off nadir, ensuring maximum light and low brightness\u003c\/li\u003e\n\t\u003cli\u003eBlack aiming mechanism preserves dark aperture.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eTrims Style\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eSelf Flanged and Flush Mount reflectors utilize wire form spring retention for tight, secure fit to ceiling\u003c\/li\u003e\n\t\u003cli\u003eSelf Flanged reflectors with polished or optional white painted flange\u003c\/li\u003e\n\t\u003cli\u003eFor flush mount installations in drywall ceilings use the FMA5 flush mount adapter\u003c\/li\u003e\n\t\u003cli\u003eFor flush mount installations in wood, stone, or tile ceilings the FMA5-SC*** must be used (specify ceiling thickness\u003cbr\u003e\n\tand adapter finish).\u003cbr\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eSee PDF Spec for trim selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eLED Driver\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eSeven (7) driver options available to accommodate 120-277V input and multiple control protocols\u003c\/li\u003e\n\t\u003cli\u003eFor a list of compatible dimmers, refer to ACLXLED3-DIM\u003c\/li\u003e\n\t\u003cli\u003ePower Factor \u0026gt; 0.9\u003c\/li\u003e\n\t\u003cli\u003eField replaceable from below or above ceiling.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eLife\u003c\/strong\u003e Rated for 50,000 hrs at 70% lumen maintenance.\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eWarranty\u003c\/strong\u003e 5 years from date of purchase on LED components\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eCodes\/Labels\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eUL and cUL listed for through branch wiring, damp locations. Wet location listed with certain trims\u003c\/li\u003e\n\t\u003cli\u003eIC housings meet energy code Air Leakage requirements per ASTM E283\u003c\/li\u003e\n\t\u003cli\u003eENERGY STAR® Qualified with select trims\u003c\/li\u003e\n\t\u003cli\u003eIC rated luminaires with 90CRI light engine are certified to high efficacy requirements of California T24 with select color temperatures and\u003cbr\u003e\n\ttrims\u003c\/li\u003e\n\t\u003cli\u003eIC housings are rated for direct contact with insulation including spray foam insulation with an R-Value of 3.7 per inch or\u003cbr\u003e\n\tlesss (-L, -D, -M and nLight controls not compatible)\u003c\/li\u003e\n\t\u003cli\u003eUnion made.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eNew Construction Mounting\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eFeatures patented (US Patent 8,038,113) Pro-VI™ bar hanger system, permitting quick placement of housing with 24” on-center joists or suspended ceilings\u003c\/li\u003e\n\t\u003cli\u003eAll fixtures also feature vertically adjustable mounting brackets (butterfly brackets)\u003c\/li\u003e\n\t\u003cli\u003eCenterline indicators on plaster frame and patented (US Patent 8,277,090) Tru-Line™ Platform featuring +\/- ½” translation aids fixture alignment after installation, prior to drywall.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eJunction Box\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eIC fixtures rated for 4, non-IC rated for 8 No. 12 \n  AWG 90° C through branch circuit conductors and includes (6) ½”, (1) ¾”, and (4) Non-metallic sheathed cable knock-outs\n\t\u003c\/li\u003e\n\t\u003cli\u003ePush-in electrical connectors for field connections.\u003cbr\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eCeiling Thickness\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003e1\/2” – 7\/8” ceiling standard\u003c\/li\u003e\n\t\u003cli\u003eFor thicker ceilings, order CTA5-125 (7\/8”-1 1\/4”), CTA5-163 (1 1\/4”- 1 5\/8”) or CTA5-200 (1 5\/8”– 2”)\u003c\/li\u003e\n\t\u003cli\u003eCTA5 not required for wood, stone, or tile flush mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eORDERING INFORMATION\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n\t \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/IC512L-IC517L-IC522L-IC527L-TC532L-ordering-information_36380e45-50f1-48ee-8a94-2c8b414decb1.jpg?v=1762042487\"\u003e\n\u003c\/p\u003e","brand":"Juno Lighting","offers":[{"title":"Default Title","offer_id":45481539830067,"sku":"Juno-TC532L-827-F-EZB","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/products\/Juno-TC532L-827-F-EZB-2.jpg?v=1690043942"}],"url":"https:\/\/electricbargainstores.com\/collections\/juno-aculux-recessed-lighting-tc532l-4-inch-adjustable-led-housings.oembed?page=2","provider":"Electric Bargain Store","version":"1.0","type":"link"}