{"title":"Kim Lighting Transformers and Accessories","description":"","products":[{"product_id":"kim-klv-pc1","title":"Kim Lighting KLV-PC1 Photocell, Direct Mount to Enclosure Knockout in Right-Handside of Transformer Enclosure","description":"Photocell, Direct mount to enclosure knockout in right-handside of transformer enclosure.","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45483366187315,"sku":"Kim-KLV-PC1","price":77.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-KLV-PC1-2.jpg?v=1735491235"},{"product_id":"kim-klv-pc2","title":"Kim Lighting KLV-PC2 Photocell, Remote Mount With 10' Cord for Installation in Any 1\/2\" NPT Cover Plate","description":"Photocell, Remote mount with 10' cord for installation in any K\" NPT cover plate (by others).","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45483366220083,"sku":"Kim-KLV-PC2","price":106.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-KLV-PC2-2.jpg?v=1735491255"},{"product_id":"kim-klv-tc24","title":"Kim Lighting KLV-TC24 Plug-in Time Clock, Plugs Into Receptacle Provided in Transformer Enclosure","description":"Plug-in Time Clock, Plugs into receptacle provided in transformer enclosure.","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45483366252851,"sku":"Kim-KLV-TC24","price":80.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-KLV-TC24-2.jpg?v=1735491275"},{"product_id":"kim-klv410","title":"Kim Lighting KLV410 Sealed Connector for 12V Cable #8 or #12","description":"The standard sealed connector, KLV410, is for connecting one fixture to the cable.\u003cbr\u003e\nThe standard connector employs piercing screws, and the branch connector utilizes\ncompression type connectors and brass bussbars.\u003cbr\u003e\nAll connections are totally sealed and waterproofed with the dielectric mastic\nprovided. Maximum design flexibility is assured since fixtures can be easily added or\nrelocated by installing a new sealed connector.\u003cbr\u003eConnectors may be buried, installed at grade, or surface mounted. They are designed to eliminate the common problem of corrosion and oxidation of the connections, which can cause power interruption. Injection molded in black Valox®, the two-piece connectors have stainless steel screws.","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45483408916787,"sku":"Kim-KLV410","price":33.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-KLV410-2.jpg?v=1735496766"},{"product_id":"kim-klv427","title":"Kim Lighting KLV427 500' #12-2 12 Volt Cable","description":"\u003cp\u003e\u003cstrong\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe greatest benefit of installing a low voltage lighting system is the ability to conceal\n  the flexible electrical cable directly under as little as 6\" of soil cover, without the need\n  for conduits or raceways.\u003cbr\u003e\n  Voltage drop for KLV600 series transformers is a function of cable size, circuit\n  length and connected fixture wattage. In order to attain good lumen output, it is\n  recommended that each fixture be provided a minimum of 10 volts. Use the chart\n  below to estimate the cable size required and maximum circuit distance allowable\n  to maintain 10 volts to the farthest connected fixture on a cable run.\u003cbr\u003e\nCopper stranded landscape cable, black, UL recognized.\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-cable-ordering-information_e06ca418-5dee-4c65-a396-acdde719cade.jpg?v=1762251789\"\u003e\u003c\/p\u003e\n\u003cp\u003e600 watt transformer consists of (2) 250 watt branches, requiring a minimum\n  of (2) branch circuit cable runs.\u003cbr\u003e\n  900 watt transformer consists of (4) 250 watt branches, requiring a minimum\n  of (4) branch circuit cable runs.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eORDERING INFORMATION\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-cable-ordering-information2_01666093-04b5-4846-bd14-77ccd61b4df7.jpg?v=1762251790\"\u003e\u003c\/p\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45483409146163,"sku":"Kim-KLV427","price":781.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-KLV427-2.jpg?v=1735496847"},{"product_id":"kim-klv432","title":"Kim Lighting KLV432 500' #8-2 12 Volt Cable","description":"\u003cp\u003e\u003cstrong\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe greatest benefit of installing a low voltage lighting system is the ability to conceal the flexible electrical cable directly under as little as 6\" of soil cover, without the need for conduits or raceways.\u003cbr\u003eVoltage drop for KLV600 series transformers is a function of cable size, circuit length and connected fixture wattage. In order to attain good lumen output, it is recommended that each fixture be provided a minimum of 10 volts. Use the chart below to estimate the cable size required and maximum circuit distance allowable to maintain 10 volts to the farthest connected fixture on a cable run.\u003cbr\u003eCopper stranded landscape cable, black, UL recognized.\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-cable-ordering-information_cb78a3da-91d7-41b2-b2d5-7e8e03e3862c.jpg?v=1762251794\"\u003e\u003c\/p\u003e\u003cp\u003e600 watt transformer consists of (2) 250 watt branches, requiring a minimum of (2) branch circuit cable runs.\u003cbr\u003e900 watt transformer consists of (4) 250 watt branches, requiring a minimum of (4) branch circuit cable runs.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eORDERING INFORMATION\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-cable-ordering-information2_e20ecb8e-9a3f-4107-b1dd-b08a6c8a74cd.jpg?v=1762251796\"\u003e\u003c\/p\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45483409211699,"sku":"Kim-KLV432","price":2102.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-KLV432-2.jpg?v=1735496867"},{"product_id":"kim-klv600","title":"Kim Lighting KLV600 200W One Circuit 120V to 12-15V Multi-Tap Low Voltage Magnetic Above-Grade Transformer, Dimmable, Stainless Steel Enclosure","description":"\u003cp\u003e\u003cstrong\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e: Formed 16 ga. stainless steel enclosure with integral\n  hinge. Cover is secured with two stainless steel screws. A through\n  hole is provided in the bottom edge for a padlock (by others). 1\/2\"\n  knockouts on each side of the enclosure are provided for hardwiring\u003cbr\u003e\n  or accessory photocell mounting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTransformer\u003c\/strong\u003e: Core and coil type fully epoxy encapsulated. Output\n  is multi-tap 12V \/ 13V \/ 14V \/ 15V. The 200 and 300-watt units have\nsingle circuit output, the 600-watt unit has two circuits for output.\u003cspan style=\"background-color: initial;\"\u003eVariable taps provide flexibility in system design with the 12 volt tap\n  for fixtures near the transformer location and higher voltages for more\nremote fixtures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Block\u003c\/strong\u003e: 80-amp euro-style terminal block.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCircuit Breaker\u003c\/strong\u003e: 25 amp magnetic circuit breaker (1) per circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCord\u003c\/strong\u003e: Six foot, heavy duty outdoor power cord is provided\n  and installed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e: UL Listed to U.S. and Canadian safety standards for\n  wet locations. Fixture manufacturer shall employ a quality program\n  that is certified to meet the ISO 9001:2000 standard.\u003c\/p\u003e\n\n\tCopper stranded landscape cable, black, UL recognized\u003cbr\u003e\u003cbr\u003e\u003cb\u003eORDERING INFORMATION\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-above-grade-transformers-ordering-information_34dfd3d9-c65b-4a8a-bf7f-5baeb5e938e5.jpg?v=1762251845\"\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eNote\u003c\/b\u003e: Output wattage is not to exceed 25 amps on each circuit. Weather conditions must be considered when determining load on transformers, hot weather areas should reduce the output wattage to prevent heat build-up on circuit breakers. The voltage at each fixture must not exceed 12 volt. Load and distance must be considered when determining which voltage tap to use. A good maintenance program is required to replace lamps as they burn out to prevent over-voltage of remaining lamps.\u003cbr\u003e\u003cbr\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45483410129203,"sku":"Kim-KLV600","price":738.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-KLV600-2.jpg?v=1735497307"},{"product_id":"kim-klv605","title":"Kim Lighting KLV605 300W One Circuit 120V to 12-15V Multi-Tap Low Voltage Magnetic Above-Grade Transformer, Dimmable, Stainless Steel Enclosure","description":"\u003cp\u003e\u003cstrong\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e: Formed 16 ga. stainless steel enclosure with integral\n  hinge. Cover is secured with two stainless steel screws. A through\n  hole is provided in the bottom edge for a padlock (by others). 1\/2\"\n  knockouts on each side of the enclosure are provided for hardwiring\u003cbr\u003e\n  or accessory photocell mounting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTransformer\u003c\/strong\u003e: Core and coil type fully epoxy encapsulated. Output\n  is multi-tap 12V \/ 13V \/ 14V \/ 15V. The 200 and 300-watt units have\nsingle circuit output, the 600-watt unit has two circuits for output.\u003cspan style=\"background-color: initial;\"\u003eVariable taps provide flexibility in system design with the 12 volt tap\n  for fixtures near the transformer location and higher voltages for more\nremote fixtures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Block\u003c\/strong\u003e: 80-amp euro-style terminal block.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCircuit Breaker\u003c\/strong\u003e: 25 amp magnetic circuit breaker (1) per circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCord\u003c\/strong\u003e: Six foot, heavy duty outdoor power cord is provided\n  and installed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e: UL Listed to U.S. and Canadian safety standards for\n  wet locations. Fixture manufacturer shall employ a quality program\n  that is certified to meet the ISO 9001:2000 standard.\u003c\/p\u003e\n\n\tCopper stranded landscape cable, black, UL recognized\u003cbr\u003e\u003cbr\u003e\u003cb\u003eORDERING INFORMATION\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-above-grade-transformers-ordering-information_34dfd3d9-c65b-4a8a-bf7f-5baeb5e938e5.jpg?v=1762251845\"\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eNote\u003c\/b\u003e: Output wattage is not to exceed 25 amps on each circuit. Weather conditions must be considered when determining load on transformers, hot weather areas should reduce the output wattage to prevent heat build-up on circuit breakers. The voltage at each fixture must not exceed 12 volt. Load and distance must be considered when determining which voltage tap to use. A good maintenance program is required to replace lamps as they burn out to prevent over-voltage of remaining lamps.\u003cbr\u003e\u003cbr\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45483410194739,"sku":"Kim-KLV605","price":784.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-KLV605-2.jpg?v=1735497329"},{"product_id":"kim-klv620","title":"Kim Lighting KLV620 600W One Circuit 120V to 12-15V Multi-Tap Low Voltage Magnetic Above-Grade Transformer, Dimmable, Stainless Steel Enclosure","description":"\u003cp\u003e\u003cstrong\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e: Formed 16 ga. stainless steel enclosure with integral\n  hinge. Cover is secured with two stainless steel screws. A through\n  hole is provided in the bottom edge for a padlock (by others). 1\/2\"\n  knockouts on each side of the enclosure are provided for hardwiring\u003cbr\u003e\n  or accessory photocell mounting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTransformer\u003c\/strong\u003e: Core and coil type fully epoxy encapsulated. Output\n  is multi-tap 12V \/ 13V \/ 14V \/ 15V. The 200 and 300-watt units have\nsingle circuit output, the 600-watt unit has two circuits for output.\u003cspan style=\"background-color: initial;\"\u003eVariable taps provide flexibility in system design with the 12 volt tap\n  for fixtures near the transformer location and higher voltages for more\nremote fixtures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Block\u003c\/strong\u003e: 80-amp euro-style terminal block.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCircuit Breaker\u003c\/strong\u003e: 25 amp magnetic circuit breaker (1) per circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCord\u003c\/strong\u003e: Six foot, heavy duty outdoor power cord is provided\n  and installed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e: UL Listed to U.S. and Canadian safety standards for\n  wet locations. Fixture manufacturer shall employ a quality program\n  that is certified to meet the ISO 9001:2000 standard.\u003c\/p\u003e\n\n\tCopper stranded landscape cable, black, UL recognized\u003cbr\u003e\u003cbr\u003e\u003cb\u003eORDERING INFORMATION\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-above-grade-transformers-ordering-information_34dfd3d9-c65b-4a8a-bf7f-5baeb5e938e5.jpg?v=1762251845\"\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eNote\u003c\/b\u003e: Output wattage is not to exceed 25 amps on each circuit. Weather conditions must be considered when determining load on transformers, hot weather areas should reduce the output wattage to prevent heat build-up on circuit breakers. The voltage at each fixture must not exceed 12 volt. Load and distance must be considered when determining which voltage tap to use. A good maintenance program is required to replace lamps as they burn out to prevent over-voltage of remaining lamps.\u003cbr\u003e\u003cbr\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45483410227507,"sku":"Kim-KLV620","price":706.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-KLV620-2.jpg?v=1735497351"},{"product_id":"kim-klv625","title":"Kim Lighting KLV625 900W Thress Circuits (300W each) 120V to 12-15V Multi-Tap Low Voltage Magnetic Above-Grade Transformer, Dimmable, Stainless Steel Enclosure","description":"\u003cp\u003e\u003cstrong\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e: Formed 16 ga. stainless steel enclosure with integral\n  hinge. Cover is secured with two stainless steel screws. A through\n  hole is provided in the bottom edge for a padlock (by others). 1\/2\"\n  knockouts on each side of the enclosure are provided for hardwiring\u003cbr\u003e\n  or accessory photocell mounting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTransformer\u003c\/strong\u003e: Core and coil type fully epoxy encapsulated. Output\n  is multi-tap 12V \/ 13V \/ 14V \/ 15V. The 200 and 300-watt units have\nsingle circuit output, the 600-watt unit has two circuits for output.\u003cspan style=\"background-color: initial;\"\u003eVariable taps provide flexibility in system design with the 12 volt tap\n  for fixtures near the transformer location and higher voltages for more\nremote fixtures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Block\u003c\/strong\u003e: 80-amp euro-style terminal block.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCircuit Breaker\u003c\/strong\u003e: 25 amp magnetic circuit breaker (1) per circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCord\u003c\/strong\u003e: Six foot, heavy duty outdoor power cord is provided\n  and installed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e: UL Listed to U.S. and Canadian safety standards for\n  wet locations. Fixture manufacturer shall employ a quality program\n  that is certified to meet the ISO 9001:2000 standard.\u003c\/p\u003e\n\n\tCopper stranded landscape cable, black, UL recognized\u003cbr\u003e\u003cbr\u003e\u003cb\u003eORDERING INFORMATION\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-above-grade-transformers-ordering-information_34dfd3d9-c65b-4a8a-bf7f-5baeb5e938e5.jpg?v=1762251845\"\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eNote\u003c\/b\u003e: Output wattage is not to exceed 25 amps on each circuit. Weather conditions must be considered when determining load on transformers, hot weather areas should reduce the output wattage to prevent heat build-up on circuit breakers. The voltage at each fixture must not exceed 12 volt. Load and distance must be considered when determining which voltage tap to use. A good maintenance program is required to replace lamps as they burn out to prevent over-voltage of remaining lamps.\u003cbr\u003e\u003cbr\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45483410293043,"sku":"Kim-KLV625","price":1501.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-KLV625-2.jpg?v=1735497371"},{"product_id":"kim-klv640","title":"Kim Lighting KLV640 300W One Circuit 120V to 12-15V Multi-Tap Low Voltage Magnetic In-Grade Transformer, Dimmable, Stainless Steel Enclosure","description":"\u003cp\u003e\n\t\u003cstrong\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eEnclosure\u003c\/strong\u003e: Epoxy encapsulated in a stainless-steel\n  burial enclosure.\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eKLV640\u003c\/strong\u003e 300W toroidal transformer has 120Volt (only) input\n  and a 12V \/ 13V \/ 14V \/ 15V multi-tap output.\n\u003c\/p\u003e\n\u003cp\u003e\n\t\u003cstrong\u003eCertification\u003c\/strong\u003e: UL Listed to U.S. and Canadian safety standards\n  for wet locations.\n\t\u003cbr\u003e\u003cbr\u003e\u003cb\u003eORDERING INFORMATION\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/in-grade-transformer-ordering-information_47f60427-d31c-49c2-996b-e5cb161fbdc4.jpg?v=1762251854\"\u003e\u003cbr\u003e\u003c\/b\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cbr\u003eNote: Output wattage is not to exceed 25 amps on\n  each circuit. Weather conditions must be considered\n  when determining load on transformers, hot weather\n  areas should reduce the output wattage to prevent\n  heat build-up on circuit breakers. The voltage at each\n  fixture must not exceed 12 volt. Load and distance\n  must be considered when determining which voltage\n  tap to use. A good maintenance programis required to\n  replace lamps as they burn out to prevent over-voltage\nof  remaining lamps.\u003c\/span\u003e\u003c\/p\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45483410555187,"sku":"Kim-KLV640","price":789.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-KLV640-2.jpg?v=1735497393"},{"product_id":"kim-klv645","title":"Kim Lighting KLV645 600W One Circuit 120V to 12-15V Multi-Tap Low Voltage Magnetic In-Grade Transformer, Dimmable, Stainless Steel Enclosure","description":"\u003cp\u003e\u003cstrong\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e: Epoxy encapsulated in a stainless-steel\n  burial enclosure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKLV645\u003c\/strong\u003e 600W toroidal transformer has a 120V (only) input and\n  a dual 300W 12V \/ 13V \/ 14V \/ 15V multi-tap output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e: UL Listed to U.S. and Canadian safety standards\nfor wet locations.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eORDERING INFORMATION\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/in-grade-transformer-ordering-information_47f60427-d31c-49c2-996b-e5cb161fbdc4.jpg?v=1762251854\"\u003e\u003cbr\u003e\u003c\/b\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cbr\u003eNote: Output wattage is not to exceed 25 amps on\n  each circuit. Weather conditions must be considered\n  when determining load on transformers, hot weather\n  areas should reduce the output wattage to prevent\n  heat build-up on circuit breakers. The voltage at each\n  fixture must not exceed 12 volt. Load and distance\n  must be considered when determining which voltage\n  tap to use. A good maintenance programis required to\n  replace lamps as they burn out to prevent over-voltage\nof  remaining lamps.\n\t\u003c\/span\u003e\n\u003c\/p\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45483410587955,"sku":"Kim-KLV645","price":1000.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-KLV645-2.jpg?v=1735497414"},{"product_id":"kim-klv660","title":"Kim Lighting KLV660 300W One Circuit 277V to 12-15V Multi-Tap Low Voltage Magnetic In-Grade Transformer, Dimmable, Stainless Steel Enclosure","description":"\u003cp\u003e\u003cstrong\u003ePRODUCT SPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e: Epoxy encapsulated in a stainless-steel\n  burial enclosure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKLV660\u003c\/strong\u003e 300W\n  toroidal transformer has a 277V input and a single 12V output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e: UL Listed to U.S. and Canadian safety standards\nfor wet locations.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eORDERING INFORMATION\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/in-grade-transformer-ordering-information_47f60427-d31c-49c2-996b-e5cb161fbdc4.jpg?v=1762251854\"\u003e\u003cbr\u003e\u003c\/b\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cbr\u003eNote: Output wattage is not to exceed 25 amps on\n  each circuit. Weather conditions must be considered\n  when determining load on transformers, hot weather\n  areas should reduce the output wattage to prevent\n  heat build-up on circuit breakers. The voltage at each\n  fixture must not exceed 12 volt. Load and distance\n  must be considered when determining which voltage\n  tap to use. A good maintenance programis required to\n  replace lamps as they burn out to prevent over-voltage\nof  remaining lamps.\n\t\u003c\/span\u003e\n\u003c\/p\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45483410620723,"sku":"Kim-KLV660","price":789.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Kim-KLV660-2.jpg?v=1735497435"}],"url":"https:\/\/electricbargainstores.com\/collections\/kim-lighting-transformers-and-accessories.oembed","provider":"Electric Bargain Store","version":"1.0","type":"link"}