{"title":"NTR-15-GFST","description":"","products":[{"product_id":"lutron-ntr-15-gfst-al","title":"Lutron NTR-15-GFST-AL Nova T Duplex Self-Testing Tamper Resistant 15A 125V GFCI Receptacle in Almond, Matte Finish","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\u003cul\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" width=\"100%\" cellpadding=\"5\" cellspacing=\"0\" style=\"font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\" width=\"30%\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tNTR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\u003c\/td\u003e\n\t\u003ctd\u003eMatte Finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\u003cbr\u003e\u003cbr\u003e\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46795575263539,"sku":"Lutron-NTR-15-GFST-AL","price":98.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-NTR-15-GFST-AL-2.jpg?v=1737771364"},{"product_id":"lutron-ntr-15-gfst-be","title":"Lutron NTR-15-GFST-BE Nova T Duplex Self-Testing Tamper Resistant 15A 125V GFCI Receptacle in Beige, Matte Finish","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\u003cul\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" width=\"100%\" cellpadding=\"5\" cellspacing=\"0\" style=\"font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\" width=\"30%\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tNTR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\u003c\/td\u003e\n\t\u003ctd\u003eMatte Finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\u003cbr\u003e\u003cbr\u003e\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46795575558451,"sku":"Lutron-NTR-15-GFST-BE","price":98.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-NTR-15-GFST-BE-2.jpg?v=1737771378"},{"product_id":"lutron-ntr-15-gfst-bl","title":"Lutron NTR-15-GFST-BL Nova T Duplex Self-Testing Tamper Resistant 15A 125V GFCI Receptacle in Black, Matte Finish","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\u003cul\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" width=\"100%\" cellpadding=\"5\" cellspacing=\"0\" style=\"font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\" width=\"30%\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tNTR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\u003c\/td\u003e\n\t\u003ctd\u003eMatte Finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\u003cbr\u003e\u003cbr\u003e\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46795575755059,"sku":"Lutron-NTR-15-GFST-BL","price":98.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-NTR-15-GFST-BL-2.jpg?v=1737771393"},{"product_id":"lutron-ntr-15-gfst-br","title":"Lutron NTR-15-GFST-BR Nova T Duplex Self-Testing Tamper Resistant 15A 125V GFCI Receptacle Brown, Matte Finish","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\u003cul\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" width=\"100%\" cellpadding=\"5\" cellspacing=\"0\" style=\"font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\" width=\"30%\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tNTR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\u003c\/td\u003e\n\t\u003ctd\u003eMatte Finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\u003cbr\u003e\u003cbr\u003e\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46795576049971,"sku":"Lutron-NTR-15-GFST-BR","price":98.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-NTR-15-GFST-BR-2.jpg?v=1737771408"},{"product_id":"lutron-ntr-15-gfst-gr","title":"Lutron NTR-15-GFST-GR Nova T Duplex Self-Testing Tamper Resistant 15A 125V GFCI Receptacle in Gray, Matte Finish","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\u003cul\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" width=\"100%\" cellpadding=\"5\" cellspacing=\"0\" style=\"font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\" width=\"30%\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tNTR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\u003c\/td\u003e\n\t\u003ctd\u003eMatte Finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\u003cbr\u003e\u003cbr\u003e\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46795576770867,"sku":"Lutron-NTR-15-GFST-GR","price":98.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-NTR-15-GFST-GR-2.jpg?v=1737771422"},{"product_id":"lutron-ntr-15-gfst-iv","title":"Lutron NTR-15-GFST-IV Nova T Duplex Self-Testing Tamper Resistant 15A 125V GFCI Receptacle in Ivory, Matte Finish","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\u003cul\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" width=\"100%\" cellpadding=\"5\" cellspacing=\"0\" style=\"font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\" width=\"30%\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tNTR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\u003c\/td\u003e\n\t\u003ctd\u003eMatte Finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\u003cbr\u003e\u003cbr\u003e\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46795576803635,"sku":"Lutron-NTR-15-GFST-IV","price":98.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-NTR-15-GFST-IV-2.jpg?v=1737771436"},{"product_id":"lutron-ntr-15-gfst-la","title":"Lutron NTR-15-GFST-LA Nova T Duplex Self-Testing Tamper Resistant 15A 125V GFCI Receptacle in Light Almond, Matte Finish","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\u003cul\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" width=\"100%\" cellpadding=\"5\" cellspacing=\"0\" style=\"font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\" width=\"30%\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tNTR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\u003c\/td\u003e\n\t\u003ctd\u003eMatte Finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\u003cbr\u003e\u003cbr\u003e\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46795577196851,"sku":"Lutron-NTR-15-GFST-LA","price":98.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-NTR-15-GFST-LA-2.jpg?v=1737771450"},{"product_id":"lutron-ntr-15-gfst-si","title":"Lutron NTR-15-GFST-SI Nova T Duplex Self-Testing Tamper Resistant 15A 125V GFCI Receptacle in Sienna, Matte Finish","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\u003cul\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" width=\"100%\" cellpadding=\"5\" cellspacing=\"0\" style=\"font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\" width=\"30%\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tNTR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\u003c\/td\u003e\n\t\u003ctd\u003eMatte Finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\u003cbr\u003e\u003cbr\u003e\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46795577229619,"sku":"Lutron-NTR-15-GFST-SI","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-NTR-15-GFST-SI-2.jpg?v=1737771465"},{"product_id":"lutron-ntr-15-gfst-tp","title":"Lutron NTR-15-GFST-TP Nova T Duplex Self-Testing Tamper Resistant 15A 125V GFCI Receptacle in Taupe, Matte Finish","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\u003cul\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" style=\"font-size: 14px;\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd width=\"30%\" valign=\"top\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tNTR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\u003c\/td\u003e\n\t\u003ctd\u003eMatte Finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\u003cbr\u003e\u003cbr\u003e\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46795577262387,"sku":"Lutron-NTR-15-GFST-TP","price":98.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-NTR-15-GFST-TP-2.jpg?v=1737771480"},{"product_id":"lutron-ntr-15-gfst-wh","title":"Lutron NTR-15-GFST-WH Nova T Duplex Self-Testing Tamper Resistant 15A 125V GFCI Receptacle in White, Matte Finish","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\u003cul\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" style=\"font-size: 14px;\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd width=\"30%\" valign=\"top\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tNTR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\u003c\/td\u003e\n\t\u003ctd\u003eMatte Finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\u003cbr\u003e\u003cbr\u003e\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46795577688371,"sku":"Lutron-NTR-15-GFST-WH","price":98.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-NTR-15-GFST-WH-2.jpg?v=1737771494"}],"url":"https:\/\/electricbargainstores.com\/collections\/ntr-15-gfst.oembed","provider":"Electric Bargain Store","version":"1.0","type":"link"}