{"title":"PLD LED Emergency Battery Pack","description":"","products":[{"product_id":"dual-lite-pld10","title":"Dual Lite PLD10 10W LED Battery Pack, 120-277V, Polycarbonate Thermoplastic","description":"\u003cb\u003eApplication\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eThe Dual-Lite PLD10 is a universal input (120-277V) emergency\nLED battery pack that works with an AC LED driver to allow an LED\nlighting load to be used in both normal and emergency operation. \u003c\/li\u003e\n\u003cli\u003eWhen normal AC power is lost, the PLD10 operates to provide 10\nwatts of constant emergency power at a rated output voltage of\n20-56Vdc. \u003c\/li\u003e\n\u003cli\u003eThe constant power design provides backup for a\nminimum of 90 minutes with no loss of emergency lumen output. \u003c\/li\u003e\n\u003cli\u003eWhen used with emergency-only LED fixtures, no AC driver is\nneeded. \u003c\/li\u003e\n\u003cli\u003eThe UL924 Listing allows for both field and factory\ninstallations of suitable LED loads including LED luminaires, DC\nvoltage driven LED replacements for fluorescent lamps and others. \u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cb\u003eConstruction\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eThe Dual-Lite PLD10 consists of a compact case constructed of\npolycarbonate thermoplastic. \u003c\/li\u003e\n\u003cli\u003eThe unit contains a solid-state charger\nwith automatic transfer circuit, a 2-wire test switch and LED charging\nindicator light, and a high-temperature, Nickel-Cadmium battery. \u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cb\u003eInstallation\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eThe PLD10 emergency battery pack does not affect normal LED\nfixture operation and may be used with either switched or unswitched\nfixtures. \u003c\/li\u003e\n\u003cli\u003eIf a switched fixture is used, an unswitched hot lead must be\nconnected to the emergency ballast. \u003c\/li\u003e\n\u003cli\u003eThe emergency battery packs\nmust be fed from the same branch circuit as the AC LED driver. \u003c\/li\u003e\n\u003cli\u003eDue to\nits thermoplastic construction, the PLD10 must either be installed\ninside the fixture, or enclosed if remote mounted outside the\nfixture. \u003c\/li\u003e\n\u003cli\u003eThe PLD10 emergency battery pack is suitable for use in\ndamp locations where the ambient temperature is between 0°C\n(32°F) and 55°C (131°F). \u003c\/li\u003e\n\u003cli\u003eIt is not suitable for installation in\nheated air outlet fixtures and wet or hazardous location fixtures. \u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eIllumination\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eThe PLD10 will operate an LED load, that has a power rating of 10\nwatts or greater, for a minimum of 90 minutes.\u003c\/li\u003e\n\u003cli\u003eUsing the LED\nload’s efficacy in lm\/w, as published by the Design Lights\nConsortium website, Energy\nStar - Certified Products or given by the luminaire manufacturer\non product catalog specification sheets, lumen output can be\ncalculated by multiplying by the PLD10 output power (10w). \u003c\/li\u003e\n\u003cli\u003eCompliances\nUL 924 Recognized and Damp Location Listed for field installation\nUL 1310 Certified (Class 2 output)\nCSA C22.2 No. 141 (Canadian Life Safety Standard)\nNFPA 101 (Life Safety Code)\nNFPA 70 ( National Electrical Code)\nCEC-400-2014-009-CMF (CEC Battery Charger Efficiency Standard)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cb\u003eWarranty\u003c\/b\u003e\u003cbr\u003e5 Year Full Warranty","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441777008947,"sku":"Dual-Lite-PLD10","price":214.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-PLD10-2.jpg?v=1734129846"},{"product_id":"dual-lite-pld10m","title":"Dual Lite PLD10M 10W LED Battery Pack, 120-277V, Galvanized Steel","description":"\u003cb\u003eApplication\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eThe Dual-Lite PLD10M is a universal input (120-277V) emergency\nLED battery pack that works with an AC LED driver to allow an LED\nlighting load to be used in both normal and emergency operation.\u003c\/li\u003e\n\u003cli\u003eWhen normal AC power is lost, the PLD10M operates to provide 10\nwatts of constant emergency power at a rated output voltage of\n20-56Vdc.\u003c\/li\u003e\n\u003cli\u003eThe constant power design provides backup for a\nminimum of 90 minutes with no loss of emergency lumen output.\u003c\/li\u003e\n\u003cli\u003eWhen used with emergency-only LED fixtures, no AC driver is\nneeded.\u003c\/li\u003e\n\u003cli\u003eThe UL924 Listing allows for both field and factory\ninstallations of suitable LED loads including LED luminaires, DC\nvoltage driven LED replacements for fluorescent lamps and others.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eConstruction\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eThe Dual-Lite PLD10M consists of a compact case constructed of\ndurable, galvanized steel.\u003c\/li\u003e\n\u003cli\u003eThe unit contains a solid-state charger\nwith automatic transfer circuit, a 2-wire test switch and LED charging\nindicator light, and a high-temperature, Nickel-Cadmium battery.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cb\u003eInstallation\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eThe PLD10M emergency battery pack does not affect normal LED\nfixture operation and may be used with either switched or unswitched\nfixtures.\u003c\/li\u003e\n\u003cli\u003eIf a switched fixture is used, an unswitched hot lead must be\nconnected to the emergency ballast.\u003c\/li\u003e\n\u003cli\u003eThe emergency battery packs\nmust be fed from the same branch circuit as the AC LED driver.\u003c\/li\u003e\n\u003cli\u003eDue to\nits steel construction, the PLD10M is designed to be mounted outside\nthe LED fixture.\u003c\/li\u003e\n\u003cli\u003eThe PLD10M emergency battery pack is suitable for\nuse in damp locations where the ambient temperature is between 0°C\n(32°F) and 55°C (131°F).\u003c\/li\u003e\n\u003cli\u003eIt is not suitable for installation in heated air\noutlet fixtures and wet or hazardous location fixtures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cb\u003eIllumination\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eThe PLD10M will operate an LED load, that has a power rating of 10\nwatts or greater, for a minimum of 90 minutes.\u003c\/li\u003e\n\u003cli\u003eUsing the LED\nload’s efficacy in lm\/w, as published by the Design Lights\nConsortium website, Energy\nStar - Certified Products or given by the luminaire manufacturer\non product catalog specification sheets, lumen output can be\ncalculated by multiplying by the PLD10M output power (10w).\u003c\/li\u003e\n\u003cli\u003eCompliances\nUL 924 Recognized and Damp Location Listed for field installation\nUL 1310 Certified (Class 2 output)\nCSA C22.2 No. 141 (Canadian Life Safety Standard)\nNFPA 101 (Life Safety Code)\nNFPA 70 ( National Electrical Code)\nCEC-400-2014-009-CMF (CEC Battery Charger Efficiency Standard)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eWarranty\u003c\/b\u003e\u003cbr\u003e5 Year Full Warranty","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441777402163,"sku":"Dual-Lite-PLD10M","price":214.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-PLD10M-2.jpg?v=1734129863"},{"product_id":"dual-lite-pld7m","title":"Dual Lite PLD7M 7W Emergency Battery Pack, Galvanized Steel with One 24\" Conduit","description":"","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":45441778221363,"sku":"Dual-Lite-PLD7M","price":184.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-PLD7M-2.jpg?v=1734129880"},{"product_id":"dual-lite-pld9-2h","title":"Dual Lite PLD9-2H 9W LED Battery Pack, 120 minutes, 120-277V","description":"\u003cb\u003ePRODUCT FAMILY SPECIFICATIONS\u003cbr\u003e\u003c\/b\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cb\u003eAPPLICATION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eThe Dual-Lite PLD9\/10 is a universal input \u003c\/span\u003e(120-277V) emergency LED battery pack that works with an AC LED driver to allow an LED lighting load to be used in both normal and emergency operation.\u003c\/li\u003e\n\u003cli\u003eWhen normal AC power is lost, the PLD9\/10 operates to provide 9 or 10 watts of constant emergency power at a rated output voltage of 20-56Vdc\u003c\/li\u003e\n\u003cli\u003eThe constant power design provides backup for a minimum of 90 minutes (10 watt output), or 120 minutes (9 watt output) with no loss of emergency lumen output\u003c\/li\u003e\n\u003cli\u003eWhen used with emergency-only LED fixtures, no AC driver is needed\u003c\/li\u003e\n\u003cli\u003eThe UL924 Listing allows for both field and factory installations of suitable LED loads including LED luminaires, DC voltage driven LED replacements for fluorescent lamps and others\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/span\u003e\u003cb\u003eCONSTRUCTION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eCompact case constructed of polycarbonate \u003c\/span\u003ethermoplastic.\u003c\/li\u003e\n\u003cli\u003eThe unit contains a solid-state charger with automatic transfer circuit, a 2-wire test switch and LED charging indicator light, and a high-temperature, Nickel-Cadmium battery\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cb\u003eINSTALLATION\u003cbr\u003e\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eThe PLD9\/10 emergency battery pack does \u003c\/span\u003enot affect normal LED fixture operation and may be used with either switched or unswitched fixtures\u003c\/li\u003e\n\u003cli\u003eIf a switched fixture is used, an unswitched hot lead must be connected to the emergency ballast\u003c\/li\u003e\n\u003cli\u003eThe emergency battery packs must be fed from the same branch circuit as the AC\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/span\u003e\n\u003c\/div\u003e\u003cb\u003eLED driver\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eDue to its thermoplastic construction, the \u003c\/span\u003ePLD9\/10 must either be installed inside the fixture, or enclosed if remote mounted outside the fixture\u003c\/li\u003e\n\u003cli\u003eThe PLD emergency battery pack is suitable for use in damp locations where the ambient temperature is between 0°C (32°F) and 55°C (131°F). It is not suitable for installation in heated air outlet fixtures and wet or hazardous location fixtures\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv\u003e\n\u003cb\u003eILLUMINATION\u003c\/b\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eThe PLD9\/10 will operate an LED load, that \u003c\/span\u003ehas a power rating of 10 watts or greater, for a minimum of 90 minutes , or 9 watts or greater for a minimum of 120 minutes\u003c\/li\u003e\n\u003cli\u003eUsing the LED load’s efficacy in lm\/w, as published by the Design Lights Consortium website (http:\/\/www.designlights.org), Energy Star - Certified Products - product finder website (http:\/\/www.energystar.gov\/productfinder) or given by the luminaire manufacturer on product catalog specification sheets, lumen output can be calculated by multiplying by the PLD9\/10 \u003cspan style=\"background-color: initial;\"\u003eoutput power (10w or 9w).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/span\u003e\n\u003c\/div\u003e\u003cb\u003eCOMPLIANCE\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eUL 924 Recognized and Damp Location \u003c\/span\u003eListed for field installation\u003c\/li\u003e\n\u003cli\u003eUL 1310 Certified (Class 2 output)\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 141 (Canadian Life Safety Standard, PLD10 Only)\u003c\/li\u003e\n\u003cli\u003eNFPA 101 (Life Safety Code)\u003c\/li\u003e\n\u003cli\u003eNFPA 70 ( National Electrical Code)\u003c\/li\u003e\n\u003cli\u003eCEC Title 20 Compliant (CEC Battery Charger Efficiency Standard)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eWARRANTY\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003e5 Year Full Warranty\u003c\/span\u003e\u003c\/li\u003e\u003c\/ul\u003e \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/dual-lite-PLD9-ordering-information.jpg?v=1775811527\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":53222792692019,"sku":"Dual-Lite-PLD9-2H","price":168.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-PLD9-2H-2.jpg?v=1775811530"},{"product_id":"dual-lite-pld10-10w-led-battery-pack","title":"Dual Lite PLD10+ 10W LED Battery Pack","description":"\u003cb\u003ePRODUCT SPECIFICATIONS\u003cbr\u003e\u003cspan style=\"background-color: initial;\"\u003eAPPLICATION\u003c\/span\u003e\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eThe Dual-Lite PLD10 Plus is an intelligent 2-wire (120\/277V) emergency LED battery pack that works with an AC LED driver (Max. 1.2A) to allow an LED lighting load to be used in both normal and emergency operation.\u003c\/li\u003e\n\u003cli\u003eWhen normal AC power is lost, the PLD10 Plus operates to provide emergency power at a rated output voltage of 20-56VDC for a \u003cspan style=\"background-color: initial;\"\u003eminimum of 90 minutes.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003eWhen used with emergency-only LED fixtures, no AC driver is needed.\u003c\/li\u003e\n\u003cli\u003eThe UL924 Listing allows for both field and factory installations of suitable LED loads including LED luminaires, DC voltage driven \u003cspan style=\"background-color: initial;\"\u003eLED replacements for fluorescent lamps and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eothers.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eCONSTRUCTION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eCompact case constructed of polycarbonate \u003c\/span\u003ethermoplastic.\u003c\/li\u003e\n\u003cli\u003eThe unit contains a solid-state charger with automatic transfer circuit, a 2-wire test switch, LED charging indicator light and a \u003cspan style=\"background-color: initial;\"\u003eLiFePO4 battery.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eINSTALLATION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eThe PLD10 Plus emergency battery pack \u003c\/span\u003edoes not affect normal LED fixture operation and may be used with either switched or unswitched fixtures.\u003c\/li\u003e\n\u003cli\u003eIf a switched fixture is used, an unswitched hot lead must be connected to the emergency battery.\u003c\/li\u003e\n\u003cli\u003eThe emergency battery pack must be fed from the same branch circuit as the AC LED driver.\u003c\/li\u003e\n\u003cli\u003eDue to its thermoplastic construction, the \u003cspan style=\"background-color: initial;\"\u003ePLD10 Plus must either be installed inside \u003c\/span\u003ethe fixture, or enclosed if remote mounted \u003cspan style=\"background-color: initial;\"\u003eoutside the fixture.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003eThe PLD10 Plus emergency battery pack is suitable for use in damp locations where the ambient temperature is between 0°C (32°F) and 55°C (131°F). It is not suitable for installation in heated air outlet fixtures and wet or hazardous location fixtures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eILLUMINATION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eThe PLD10 Plus will operate an LED load, \u003c\/span\u003ethat has a power rating of 10 watts or greater, for a minimum of 90 minutes.\u003c\/li\u003e\n\u003cli\u003eAdditionally, PLD10 Plus is compatible with GE Lamps Type C LED tubes providing up to 1800 lumens of emergency lighting.\u003c\/li\u003e\n\u003cli\u003eCurrent's Dual-Lite and GE Lamps brands provide complete portfolios of innovative products with a proven record of quality and \u003cspan style=\"background-color: initial;\"\u003eresults. Our award-winning family of brands \u003c\/span\u003eis dedicated to offering bold integrated \u003cspan style=\"background-color: initial;\"\u003esolutions to fulfill the needs of any spec. \u003c\/span\u003eLearn more about GE Lamps - Type C LED Tubes: \u003ca href=\"https:\/\/cdn.currentlighting.com\/site\/specsheet\/GEL193-LED-Tubes-Type-C-Spec-Sheet.pdf\" style=\"background-color: initial;\"\u003ehttps:\/\/cdn.currentlighting.com\/site\/\u003c\/a\u003especsheet\/GEL193-LED-Tubes-Type-C-Spec-Sheet.pdf\u003c\/li\u003e\n\u003cli\u003eDuring the initial 90 minutes of emergency operation, the PLD10 Plus will provide 10W of constant power. After the initial 90 minutes, the PLD10 Plus will provide 6.5W of constant power for an overall minimum of 120 minutes. See operating temperatures for \u003cspan style=\"background-color: initial;\"\u003edetails.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003eUsing the LED load’s efficacy in lm\/w, as published by the Design Lights Consortium website (http:\/\/www.designlights.org), Energy Star - Certified Products - product finder website (http:\/\/www.energystar.gov\/productfinder) or given by the luminaire manufacturer on product catalog \u003cspan style=\"background-color: initial;\"\u003especification sheets, lumen output can be \u003c\/span\u003ecalculated by multiplying by the PLD10 Plus \u003cspan style=\"background-color: initial;\"\u003eoutput power (10W).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eCOMPLIANCES\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eUL 924 Listed and Damp Location Listed for \u003c\/span\u003efield installation\u003c\/li\u003e\n\u003cli\u003eUL 1310 Certified (Class 2 output)\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 141 (Canadian Life Safety Standard)\u003c\/li\u003e\n\u003cli\u003eNFPA 101 (Life Safety Code)\u003c\/li\u003e\n\u003cli\u003eNFPA 70 (National Electrical Code)\u003c\/li\u003e\n\u003cli\u003eCEC Title 20 Compliant (CEC Battery Charger Efficiency Standard)\u003c\/li\u003e\n\u003cli\u003eFCC Certified\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eWARRANTY\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003e5 Year Full\u003c\/span\u003e\u003c\/li\u003e\u003c\/ul\u003e \u003cbr\u003e\u003cimg src=\"\/v\/vspfiles\/assets\/images\/dual-lite-PLD10+-ordering-information.jpg\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":53377989247283,"sku":"Dual-Lite-PLD10+","price":214.5,"currency_code":"USD","in_stock":true}]},{"product_id":"dual-lite-pld10m-plus-10w-led-battery-pack-metal-housing","title":"Dual Lite PLD10M Plus 10W LED Battery Pack, Metal Housing","description":"\u003cb\u003ePRODUCT FAMILY SPECIFICATIONS\u003cbr\u003e\u003cspan style=\"background-color: initial;\"\u003eAPPLICATION\u003c\/span\u003e\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eThe Dual-Lite PLD10M PLUS is a 120\/277V \u003cspan style=\"background-color: initial;\"\u003eemergency LED battery pack that works with \u003c\/span\u003ean AC LED driver (Max. 1.2A) to allow an LED lighting load to be used in both normal and emergency operation.\u003c\/li\u003e\n\u003cli\u003eWhen normal AC power is lost, the PLD10M PLUS operates to provide emergency power at a rated output voltage of 20-56VDC for a minimum of 90 minutes.\u003c\/li\u003e\n\u003cli\u003eWhen used with emergency-only LED fixtures, no AC driver is needed.\u003c\/li\u003e\n\u003cli\u003eThe UL924 Listing allows for both field and factory installations of suitable LED loads including LED luminaires, DC voltage driven LED replacements for fluorescent lamps and others.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eCONSTRUCTION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eCompact case constructed of durable, \u003c\/span\u003egalvanized steel.\u003c\/li\u003e\n\u003cli\u003eThe unit contains a solid-state charger with automatic transfer circuit, a 2-wire test switch, LED charging indicator light and a LiFePO4 battery.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eINSTALLATION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eThe PLD10M PLUS emergency battery pack \u003c\/span\u003edoes not affect normal LED fixture operation and may be used with either switched or unswitched fixtures.\u003c\/li\u003e\n\u003cli\u003eIf a switched fixture is used, an unswitched hot lead must be connected to the emergency battery.\u003c\/li\u003e\n\u003cli\u003eThe emergency battery pack must be fed from the same branch circuit as the AC LED driver.\u003c\/li\u003e\n\u003cli\u003eDue to its steel construction, the PLD10M \u003cspan style=\"background-color: initial;\"\u003ePLUS is designed to be mounted outside the \u003c\/span\u003eLED fixture.\u003c\/li\u003e\n\u003cli\u003eThe PLD10M PLUS emergency battery pack \u003cspan style=\"background-color: initial;\"\u003eis suitable for use in damp locations where \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethe ambient temperature is between 0°C \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(32°F) and 55°C (131°F).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003eIt is not suitable for installation in heated air outlet fixtures and wet or hazardous location fixtures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eILLUMINATION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eThe PLD10M PLUS will operate an LED load, \u003c\/span\u003ethat has a power rating of 10 watts or greater, for a minimum of 90 minutes.\u003c\/li\u003e\n\u003cli\u003eAdditionally, PLD10M PLUS is compatible \u003cspan style=\"background-color: initial;\"\u003ewith GE Lamps Type C LED tubes providing \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eup to 1800 lumens of emergency lighting.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003eCurrent's Dual-Lite and GE Lamps brands provide complete portfolios of innovative products with a proven record of quality and \u003cspan style=\"background-color: initial;\"\u003eresults. Our award-winning family of brands \u003c\/span\u003eis dedicated to offering bold integrated solutions to fulfill the needs of any spec.\u003c\/li\u003e\n\u003cli\u003eLearn more about GE Lamps - Type C LED Tubes: \u003ca href=\"https:\/\/cdn.currentlighting.com\/site\/\" style=\"background-color: initial;\"\u003e https:\/\/cdn.currentlighting.com\/site\/\u003c\/a\u003especsheet\/GEL193-LED-Tubes-Type-C-Spec-Sheet.pdf\u003c\/li\u003e\n\u003cli\u003eDuring the initial 90 minutes of emergency operation, the PLD10M PLUS will provide 10W of constant power. After the initial 90 minutes, the PLD10M PLUS will provide 6.5W of constant power for an overall minimum of 120 minutes. See operating temperatures for details.\u003c\/li\u003e\n\u003cli\u003eUsing the LED load’s efficacy in lm\/w, as \u003cspan style=\"background-color: initial;\"\u003epublished by the Design Lights Consortium \u003c\/span\u003ewebsite (http:\/\/www.designlights.org), Energy Star - Certified Products - product finder website (http:\/\/www.energystar.gov\/productfinder) or given by the luminaire manufacturer on product catalog specification sheets, lumen output can be calculated by multiplying by the PLD10M PLUS output power (10w).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eCOMPLIANCES\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eUL 924 Listed and Damp Location Listed for \u003c\/span\u003efield installation\u003c\/li\u003e\n\u003cli\u003eUL 1310 Certified (Class 2 output)\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 141 (Canadian Life Safety Standard)\u003c\/li\u003e\n\u003cli\u003eNFPA 101 (Life Safety Code)\u003c\/li\u003e\n\u003cli\u003eNFPA 70 (National Electrical Code)\u003c\/li\u003e\n\u003cli\u003eCEC Title 20 Compliant (CEC Battery Charger Efficiency Standard)\u003c\/li\u003e\n\u003cli\u003eFCC Certified\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eWARRANTY\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003e5 Year Full\u003c\/span\u003e\u003c\/li\u003e\u003c\/ul\u003e \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/dual-lite-PLD10M-PLUS-ordering-information.jpg?v=1779332363\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":53377989935411,"sku":"Dual-Lite-PLD10M+","price":214.5,"currency_code":"USD","in_stock":true}]},{"product_id":"dual-lite-pld9m-2h","title":"Dual Lite PLD9M-2H 9W LED Battery Pack, 2 Hours, 120-277V, Galvanized Steel","description":"","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":53377990394163,"sku":"Dual-Lite-PLD9M-2H","price":147.42,"currency_code":"USD","in_stock":true}]},{"product_id":"dual-lite-pld10mplus","title":"Dual Lite PLD10M+ 10W LED Battery Pack, Metal Housing","description":"\u003cb\u003ePRODUCT FAMILY SPECIFICATIONS\u003cbr\u003e\u003cspan style=\"background-color: initial;\"\u003eAPPLICATION\u003c\/span\u003e\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eThe Dual-Lite PLD10M PLUS is a 120\/277V \u003cspan style=\"background-color: initial;\"\u003eemergency LED battery pack that works with \u003c\/span\u003ean AC LED driver (Max. 1.2A) to allow an LED lighting load to be used in both normal and emergency operation.\u003c\/li\u003e\n\u003cli\u003eWhen normal AC power is lost, the PLD10M PLUS operates to provide emergency power at a rated output voltage of 20-56VDC for a minimum of 90 minutes.\u003c\/li\u003e\n\u003cli\u003eWhen used with emergency-only LED fixtures, no AC driver is needed.\u003c\/li\u003e\n\u003cli\u003eThe UL924 Listing allows for both field and factory installations of suitable LED loads including LED luminaires, DC voltage driven LED replacements for fluorescent lamps and others.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eCONSTRUCTION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eCompact case constructed of durable, \u003c\/span\u003egalvanized steel.\u003c\/li\u003e\n\u003cli\u003eThe unit contains a solid-state charger with automatic transfer circuit, a 2-wire test switch, LED charging indicator light and a LiFePO4 battery.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eINSTALLATION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eThe PLD10M PLUS emergency battery pack \u003c\/span\u003edoes not affect normal LED fixture operation and may be used with either switched or unswitched fixtures.\u003c\/li\u003e\n\u003cli\u003eIf a switched fixture is used, an unswitched hot lead must be connected to the emergency battery.\u003c\/li\u003e\n\u003cli\u003eThe emergency battery pack must be fed from the same branch circuit as the AC LED driver.\u003c\/li\u003e\n\u003cli\u003eDue to its steel construction, the PLD10M \u003cspan style=\"background-color: initial;\"\u003ePLUS is designed to be mounted outside the \u003c\/span\u003eLED fixture.\u003c\/li\u003e\n\u003cli\u003eThe PLD10M PLUS emergency battery pack \u003cspan style=\"background-color: initial;\"\u003eis suitable for use in damp locations where \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethe ambient temperature is between 0°C \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(32°F) and 55°C (131°F).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003eIt is not suitable for installation in heated air outlet fixtures and wet or hazardous location fixtures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eILLUMINATION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eThe PLD10M PLUS will operate an LED load, \u003c\/span\u003ethat has a power rating of 10 watts or greater, for a minimum of 90 minutes.\u003c\/li\u003e\n\u003cli\u003eAdditionally, PLD10M PLUS is compatible \u003cspan style=\"background-color: initial;\"\u003ewith GE Lamps Type C LED tubes providing \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eup to 1800 lumens of emergency lighting.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003eCurrent's Dual-Lite and GE Lamps brands provide complete portfolios of innovative products with a proven record of quality and \u003cspan style=\"background-color: initial;\"\u003eresults. Our award-winning family of brands \u003c\/span\u003eis dedicated to offering bold integrated solutions to fulfill the needs of any spec.\u003c\/li\u003e\n\u003cli\u003eLearn more about GE Lamps - Type C LED Tubes: \u003ca href=\"https:\/\/cdn.currentlighting.com\/site\/\" style=\"background-color: initial;\"\u003e https:\/\/cdn.currentlighting.com\/site\/\u003c\/a\u003especsheet\/GEL193-LED-Tubes-Type-C-Spec-Sheet.pdf\u003c\/li\u003e\n\u003cli\u003eDuring the initial 90 minutes of emergency operation, the PLD10M PLUS will provide 10W of constant power. After the initial 90 minutes, the PLD10M PLUS will provide 6.5W of constant power for an overall minimum of 120 minutes. See operating temperatures for details.\u003c\/li\u003e\n\u003cli\u003eUsing the LED load’s efficacy in lm\/w, as \u003cspan style=\"background-color: initial;\"\u003epublished by the Design Lights Consortium \u003c\/span\u003ewebsite (http:\/\/www.designlights.org), Energy Star - Certified Products - product finder website (http:\/\/www.energystar.gov\/productfinder) or given by the luminaire manufacturer on product catalog specification sheets, lumen output can be calculated by multiplying by the PLD10M PLUS output power (10w).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eCOMPLIANCES\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eUL 924 Listed and Damp Location Listed for \u003c\/span\u003efield installation\u003c\/li\u003e\n\u003cli\u003eUL 1310 Certified (Class 2 output)\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 141 (Canadian Life Safety Standard)\u003c\/li\u003e\n\u003cli\u003eNFPA 101 (Life Safety Code)\u003c\/li\u003e\n\u003cli\u003eNFPA 70 (National Electrical Code)\u003c\/li\u003e\n\u003cli\u003eCEC Title 20 Compliant (CEC Battery Charger Efficiency Standard)\u003c\/li\u003e\n\u003cli\u003eFCC Certified\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eWARRANTY\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003e5 Year Full\u003c\/span\u003e\u003c\/li\u003e\u003c\/ul\u003e \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/dual-lite-PLD10M-PLUS-ordering-information_5b59b931-08a1-4c04-bbf5-b134519b46fe.jpg?v=1781690469\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":53507438838067,"sku":"Dual-Lite-PLD10MPlus","price":214.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-PLD10MPlus-2.jpg?v=1781690471"},{"product_id":"dual-lite-pld10plus","title":"Dual Lite PLD10+ 10W LED Battery Pack","description":"\u003cb\u003ePRODUCT SPECIFICATIONS\u003cbr\u003e\u003cspan style=\"background-color: initial;\"\u003eAPPLICATION\u003c\/span\u003e\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eThe Dual-Lite PLD10 Plus is an intelligent 2-wire (120\/277V) emergency LED battery pack that works with an AC LED driver (Max. 1.2A) to allow an LED lighting load to be used in both normal and emergency operation.\u003c\/li\u003e\n\u003cli\u003eWhen normal AC power is lost, the PLD10 Plus operates to provide emergency power at a rated output voltage of 20-56VDC for a \u003cspan style=\"background-color: initial;\"\u003eminimum of 90 minutes.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003eWhen used with emergency-only LED fixtures, no AC driver is needed.\u003c\/li\u003e\n\u003cli\u003eThe UL924 Listing allows for both field and factory installations of suitable LED loads including LED luminaires, DC voltage driven \u003cspan style=\"background-color: initial;\"\u003eLED replacements for fluorescent lamps and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eothers.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eCONSTRUCTION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eCompact case constructed of polycarbonate \u003c\/span\u003ethermoplastic.\u003c\/li\u003e\n\u003cli\u003eThe unit contains a solid-state charger with automatic transfer circuit, a 2-wire test switch, LED charging indicator light and a \u003cspan style=\"background-color: initial;\"\u003eLiFePO4 battery.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eINSTALLATION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eThe PLD10 Plus emergency battery pack \u003c\/span\u003edoes not affect normal LED fixture operation and may be used with either switched or unswitched fixtures.\u003c\/li\u003e\n\u003cli\u003eIf a switched fixture is used, an unswitched hot lead must be connected to the emergency battery.\u003c\/li\u003e\n\u003cli\u003eThe emergency battery pack must be fed from the same branch circuit as the AC LED driver.\u003c\/li\u003e\n\u003cli\u003eDue to its thermoplastic construction, the \u003cspan style=\"background-color: initial;\"\u003ePLD10 Plus must either be installed inside \u003c\/span\u003ethe fixture, or enclosed if remote mounted \u003cspan style=\"background-color: initial;\"\u003eoutside the fixture.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003eThe PLD10 Plus emergency battery pack is suitable for use in damp locations where the ambient temperature is between 0°C (32°F) and 55°C (131°F). It is not suitable for installation in heated air outlet fixtures and wet or hazardous location fixtures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eILLUMINATION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eThe PLD10 Plus will operate an LED load, \u003c\/span\u003ethat has a power rating of 10 watts or greater, for a minimum of 90 minutes.\u003c\/li\u003e\n\u003cli\u003eAdditionally, PLD10 Plus is compatible with GE Lamps Type C LED tubes providing up to 1800 lumens of emergency lighting.\u003c\/li\u003e\n\u003cli\u003eCurrent's Dual-Lite and GE Lamps brands provide complete portfolios of innovative products with a proven record of quality and \u003cspan style=\"background-color: initial;\"\u003eresults. Our award-winning family of brands \u003c\/span\u003eis dedicated to offering bold integrated \u003cspan style=\"background-color: initial;\"\u003esolutions to fulfill the needs of any spec. \u003c\/span\u003eLearn more about GE Lamps - Type C LED Tubes: \u003ca href=\"https:\/\/cdn.currentlighting.com\/site\/specsheet\/GEL193-LED-Tubes-Type-C-Spec-Sheet.pdf\" style=\"background-color: initial;\"\u003ehttps:\/\/cdn.currentlighting.com\/site\/\u003c\/a\u003especsheet\/GEL193-LED-Tubes-Type-C-Spec-Sheet.pdf\u003c\/li\u003e\n\u003cli\u003eDuring the initial 90 minutes of emergency operation, the PLD10 Plus will provide 10W of constant power. After the initial 90 minutes, the PLD10 Plus will provide 6.5W of constant power for an overall minimum of 120 minutes. See operating temperatures for \u003cspan style=\"background-color: initial;\"\u003edetails.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003eUsing the LED load’s efficacy in lm\/w, as published by the Design Lights Consortium website (http:\/\/www.designlights.org), Energy Star - Certified Products - product finder website (http:\/\/www.energystar.gov\/productfinder) or given by the luminaire manufacturer on product catalog \u003cspan style=\"background-color: initial;\"\u003especification sheets, lumen output can be \u003c\/span\u003ecalculated by multiplying by the PLD10 Plus \u003cspan style=\"background-color: initial;\"\u003eoutput power (10W).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eCOMPLIANCES\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eUL 924 Listed and Damp Location Listed for \u003c\/span\u003efield installation\u003c\/li\u003e\n\u003cli\u003eUL 1310 Certified (Class 2 output)\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 141 (Canadian Life Safety Standard)\u003c\/li\u003e\n\u003cli\u003eNFPA 101 (Life Safety Code)\u003c\/li\u003e\n\u003cli\u003eNFPA 70 (National Electrical Code)\u003c\/li\u003e\n\u003cli\u003eCEC Title 20 Compliant (CEC Battery Charger Efficiency Standard)\u003c\/li\u003e\n\u003cli\u003eFCC Certified\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eWARRANTY\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003e5 Year Full\u003c\/span\u003e\u003c\/li\u003e\u003c\/ul\u003e \u003cbr\u003e\u003cimg src=\"\/v\/vspfiles\/assets\/images\/dual-lite-PLD10+-ordering-information.jpg\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":53507441328435,"sku":"Dual-Lite-PLD10Plus","price":214.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-PLD10Plus-2.jpg?v=1781690532"}],"url":"https:\/\/electricbargainstores.com\/collections\/pld-led-emergency-battery-pack.oembed","provider":"Electric Bargain Store","version":"1.0","type":"link"}