{"title":"SCR-15-GFST","description":"","products":[{"product_id":"lutron-scr-15-gfst-bg","title":"Lutron SCR-15-GFST-BG Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle, in Blue Stone","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\n\u003cul\u003e\n\t\u003cli\u003e\u003ca href=\"\/Lutron-Satin-Color-Claro-Wallplates-s\/4073.htm\" style=\"outline: 0px none;\"\u003eMatching Wallplate Sold Separately\u003c\/a\u003e\u003c\/li\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" style=\"font-size: 14px;\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd width=\"30%\" valign=\"top\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tSCR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tMatte Finish\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799413903667,"sku":"Lutron-SCR-15-GFST-BG","price":82.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-BG-2.jpg?v=1737826250"},{"product_id":"lutron-scr-15-gfst-bi","title":"Lutron SCR-15-GFST-BI Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle, in Biscuit","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\n\u003cul\u003e\n\t\u003cli\u003e\u003ca href=\"\/Lutron-Satin-Color-Claro-Wallplates-s\/4073.htm\" style=\"outline: 0px none;\"\u003eMatching Wallplate Sold Separately\u003c\/a\u003e\u003c\/li\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" style=\"font-size: 14px;\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd width=\"30%\" valign=\"top\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tSCR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tMatte Finish\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799414100275,"sku":"Lutron-SCR-15-GFST-BI","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-BI-2.jpg?v=1737826265"},{"product_id":"lutron-scr-15-gfst-bw","title":"Lutron SCR-15-GFST-BW  Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle in Brilliant White","description":"","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799414329651,"sku":"Lutron-SCR-15-GFST-BW","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-BW-2.jpg?v=1737826282"},{"product_id":"lutron-scr-15-gfst-cs","title":"Lutron SCR-15-GFST-CS  Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle in Cobblestone","description":"","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799414362419,"sku":"Lutron-SCR-15-GFST-CS","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-CS-2.jpg?v=1737826298"},{"product_id":"lutron-scr-15-gfst-cy","title":"Lutron SCR-15-GFST-CY  Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle in Clay","description":"","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799414395187,"sku":"Lutron-SCR-15-GFST-CY","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-CY-2.jpg?v=1737826314"},{"product_id":"lutron-scr-15-gfst-de","title":"Lutron SCR-15-GFST-DE  Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle in Deep Sea","description":"","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799414427955,"sku":"Lutron-SCR-15-GFST-DE","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-DE-2.jpg?v=1737826330"},{"product_id":"lutron-scr-15-gfst-ep","title":"Lutron SCR-15-GFST-EP  Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle in Espresso","description":"","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799414722867,"sku":"Lutron-SCR-15-GFST-EP","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-EP-2.jpg?v=1737826362"},{"product_id":"lutron-scr-15-gfst-gl","title":"Lutron SCR-15-GFST-GL  Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle in Glacier White","description":"","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799414821171,"sku":"Lutron-SCR-15-GFST-GL","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-GL-2.jpg?v=1737826410"},{"product_id":"lutron-scr-15-gfst-ht","title":"Lutron SCR-15-GFST-HT Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle, in Hot","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\n\u003cul\u003e\n\t\u003cli\u003e\u003ca href=\"\/Lutron-Satin-Color-Claro-Wallplates-s\/4073.htm\" style=\"outline: 0px;\"\u003eMatching Wallplate Sold Separately\u003c\/a\u003e\u003c\/li\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" width=\"100%\" cellpadding=\"5\" cellspacing=\"0\" style=\"font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\" width=\"30%\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tSCR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tMatte Finish\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799414919475,"sku":"Lutron-SCR-15-GFST-HT","price":51.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-HT-2.jpg?v=1737826430"},{"product_id":"lutron-scr-15-gfst-lg","title":"Lutron SCR-15-GFST-LG  Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle in Lunar Gray","description":"","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799414985011,"sku":"Lutron-SCR-15-GFST-LG","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-LG-2.jpg?v=1737826447"},{"product_id":"lutron-scr-15-gfst-ls","title":"Lutron SCR-15-GFST-LS Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle, in Limestone","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\n\u003cul\u003e\n\t\u003cli\u003e\u003ca href=\"\/Lutron-Satin-Color-Claro-Wallplates-s\/4073.htm\" style=\"outline: 0px;\"\u003eMatching Wallplate Sold Separately\u003c\/a\u003e\u003c\/li\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" width=\"100%\" cellpadding=\"5\" cellspacing=\"0\" style=\"font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\" width=\"30%\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tSCR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tMatte Finish\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799415017779,"sku":"Lutron-SCR-15-GFST-LS","price":82.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-LS-2.jpg?v=1737826463"},{"product_id":"lutron-scr-15-gfst-mi","title":"Lutron SCR-15-GFST-MI  Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle in Mist","description":"","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799415050547,"sku":"Lutron-SCR-15-GFST-MI","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-MI-2.jpg?v=1737826479"},{"product_id":"lutron-scr-15-gfst-mn","title":"Lutron SCR-15-GFST-MN Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle, in Midnight","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\n\u003cul\u003e\n\t\u003cli\u003e\u003ca href=\"\/Lutron-Satin-Color-Claro-Wallplates-s\/4073.htm\" style=\"outline: 0px none;\"\u003eMatching Wallplate Sold Separately\u003c\/a\u003e\u003c\/li\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" style=\"font-size: 14px;\" cellpadding=\"5\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\" width=\"30%\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tSCR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tMatte Finish\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799415345459,"sku":"Lutron-SCR-15-GFST-MN","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-MN-2.jpg?v=1737826495"},{"product_id":"lutron-scr-15-gfst-pb","title":"Lutron SCR-15-GFST-PB  Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle in Pebble","description":"","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799415509299,"sku":"Lutron-SCR-15-GFST-PB","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-PB-2.jpg?v=1737826545"},{"product_id":"lutron-scr-15-gfst-pd","title":"Lutron SCR-15-GFST-PD Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle, in Palladium","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\n\u003cul\u003e\n\t\u003cli\u003e\u003ca href=\"\/Lutron-Satin-Color-Claro-Wallplates-s\/4073.htm\" style=\"outline: 0px;\"\u003eMatching Wallplate Sold Separately\u003c\/a\u003e\u003c\/li\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" style=\"font-size: 14px;\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd width=\"30%\" valign=\"top\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tSCR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tMatte Finish\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799415574835,"sku":"Lutron-SCR-15-GFST-PD","price":51.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-PD-2.jpg?v=1737826561"},{"product_id":"lutron-scr-15-gfst-pl","title":"Lutron SCR-15-GFST-PL Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle, in Plum","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\n\u003cul\u003e\n\t\u003cli\u003e\u003ca href=\"\/Lutron-Satin-Color-Claro-Wallplates-s\/4073.htm\" style=\"outline: 0px;\"\u003eMatching Wallplate Sold Separately\u003c\/a\u003e\u003c\/li\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" width=\"100%\" cellpadding=\"5\" cellspacing=\"0\" style=\"font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\" width=\"30%\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tSCR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tMatte Finish\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799415640371,"sku":"Lutron-SCR-15-GFST-PL","price":82.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-PL-2.jpg?v=1737826577"},{"product_id":"lutron-scr-15-gfst-pm","title":"Lutron SCR-15-GFST-PM  Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle in Pumice","description":"","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799415673139,"sku":"Lutron-SCR-15-GFST-PM","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-PM-2.jpg?v=1737826593"},{"product_id":"lutron-scr-15-gfst-rw","title":"Lutron SCR-15-GFST-RW  Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle in Architectural White","description":"","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799415705907,"sku":"Lutron-SCR-15-GFST-RW","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-RW-2.jpg?v=1737826608"},{"product_id":"lutron-scr-15-gfst-sa","title":"Lutron SCR-15-GFST-SA  Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle in Sage","description":"","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799415738675,"sku":"Lutron-SCR-15-GFST-SA","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-SA-2.jpg?v=1737826625"},{"product_id":"lutron-scr-15-gfst-sd","title":"Lutron SCR-15-GFST-SD  Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle in Sand","description":"","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799415804211,"sku":"Lutron-SCR-15-GFST-SD","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-SD-2.jpg?v=1737826641"},{"product_id":"lutron-scr-15-gfst-sl","title":"Lutron SCR-15-GFST-SL  Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle in Slate","description":"","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799415902515,"sku":"Lutron-SCR-15-GFST-SL","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-SL-2.jpg?v=1737826677"},{"product_id":"lutron-scr-15-gfst-sr","title":"Lutron SCR-15-GFST-SR  Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle in Signal Red","description":"","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799416066355,"sku":"Lutron-SCR-15-GFST-SR","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-SR-2.jpg?v=1737826692"},{"product_id":"lutron-scr-15-gfst-sw","title":"Lutron SCR-15-GFST-SW Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle, in Snow","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\n\u003cul\u003e\n\t\u003cli\u003e\u003ca href=\"\/Lutron-Satin-Color-Claro-Wallplates-s\/4073.htm\" style=\"outline: 0px none;\"\u003eMatching Wallplate Sold Separately\u003c\/a\u003e\u003c\/li\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" style=\"font-size: 14px;\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd width=\"30%\" valign=\"top\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tSCR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tMatte Finish\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799416230195,"sku":"Lutron-SCR-15-GFST-SW","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-SW-2.jpg?v=1737826725"},{"product_id":"lutron-scr-15-gfst-tf","title":"Lutron SCR-15-GFST-TF  Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle in Truffle","description":"","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799416328499,"sku":"Lutron-SCR-15-GFST-TF","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-TF-2.jpg?v=1737826757"},{"product_id":"lutron-scr-15-gfst-tp","title":"Lutron SCR-15-GFST-TP Claro Satin Self-Testing Tamper Resistant 15A GFCI Receptacle, in Taupe","description":"\u003cb\u003eFeatures and Benefits\u003c\/b\u003e\n\u003cul\u003e\n\t\u003cli\u003e\u003ca href=\"\/Lutron-Satin-Color-Claro-Wallplates-s\/4073.htm\" style=\"outline: 0px none;\"\u003eMatching Wallplate Sold Separately\u003c\/a\u003e\u003c\/li\u003e\n\t\u003cli\u003eContinuous self-test functionality – disconnects power to \u003cspan style=\"background-color: initial;\"\u003ereceptacle if critical components are damaged and GFCI \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eprotection is lost – providing “continuous self-testing” \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ethat initiates within 2.5 seconds and is a continuous \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecycle every 30 seconds or less.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThree provisions for providing protection:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eContinuous electronic sensing, testing and evaluation \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eutilizing diagnostic software located on the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eTraditional testing mode by manually operating the \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e“test and reset” buttons utilizing a supervisory circuit as \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003especified in UL 943 section 5.15.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eAuto-sensing mode for immediate interruption for a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eground fault condition for Class A protection \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e(4 – 6 mA).\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003eManual Test – this design incorporates a full system test \u003cspan style=\"background-color: initial;\"\u003efunction. The GFCI, when manually tested, induces a \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esimulated ground fault leakage current to the printed \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003ecircuit board. This in turn causes the mechanical system \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eto react based on the action of the solenoid. The entire \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003emechanical and electronic GFCI system is reviewed for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efunctionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eReverse wire safety feature – if wired incorrectly there will \u003cspan style=\"background-color: initial;\"\u003ebe no power to the face or to downstream receptacles \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003efor added safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eClear visual indication of GFCI status — \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eLED indicating lights:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003eGreen LED (power to the device)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eRed LED (trip condition\/ground fault condition)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eFlashing Red LED (end of life)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003ePermanently installed internal tamper-resistant shutter \u003cspan style=\"background-color: initial;\"\u003emechanism capable of resisting insertion of foreign \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eelements into the device.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eInternal back wiring clamp and guide pocket — quick \u003cspan style=\"background-color: initial;\"\u003eand dependable termination.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eReceptacle face compatible with NEMA designer and \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eNovaT* designer-opening wallplates.\u003c\/span\u003e\n\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eCompliant with NEC 406.12 and NEC 517-18(c).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003ctable class=\"subpage_table\" style=\"font-size: 14px;\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd width=\"30%\" valign=\"top\"\u003e\n\t\tModel #\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tSCR-15-GFST\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tType\n\t\u003c\/td\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tSelf-Testing Tamper Resistant GFCI Receptacles\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tColor\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tMatte Finish\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tAmpere\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t15A\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"light_brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tVoltage\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\t125V\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"brown\"\u003e\n\t\u003ctd valign=\"top\"\u003e\n\t\tStandards and Certifications\n\t\u003c\/td\u003e\n\t\u003ctd\u003e\n\t\tUL\/CSA\/NOM\/UL 943 Dust Test\n\t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46799416361267,"sku":"Lutron-SCR-15-GFST-TP","price":70.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-SCR-15-GFST-TP-2.jpg?v=1737826773"}],"url":"https:\/\/electricbargainstores.com\/collections\/scr-15-gfst.oembed","provider":"Electric Bargain Store","version":"1.0","type":"link"}