{"product_id":"lutron-phpm-pa-120-wh","title":"Lutron PHPM-PA-120-WH Phase Adaptive Power Module, 16A 120V only","description":"\u003cp\u003e\u003cspan style=\"font-weight: bold;\"\u003eFeatures and Benefits\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProvides capability for a zone on a GRAFIK Eye control unit (or other product) to dim a fully loaded circuit of lighting.\u003c\/li\u003e\n\u003cli\u003eMay be used to control incandescent, electronic low-voltage, magnetic low-voltage, and neon\/ cold cathode lighting sources, as well as Lutron Tu-Wire fluorescent dimming ballasts.\u003c\/li\u003e\n\u003cli\u003eAutomatically selects leading-edge or trailing-edge dimming for low-voltage transformers.\u003c\/li\u003e\n\u003cli\u003eProvides power and dimming for one zone.\u003c\/li\u003e\n\u003cli\u003eUp to 3 power modules may be wired on a single GRAFIK Eye zone.\u003c\/li\u003e\n\u003cli\u003eModels available for 120 V~ control power.\u003c\/li\u003e\n\u003cli\u003eNot for use with non-dim loads.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-weight: bold;\"\u003eWorks with 120 V versions of:\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGRAFIK EyeR QS control units*\u003c\/li\u003e\n\u003cli\u003eGRAFIK EyeR 3000 Series control units**\u003c\/li\u003e\n\u003cli\u003eLP, LCP, and GP dimming panels**\u003c\/li\u003e\n\u003cli\u003eHomeWorks and HomeWorks QS remote power panels**\u003c\/li\u003e\n\u003cli\u003eLutron 3-wire fluorescent dimmers (consult Lutron for Vierti); see approved list in the dimmers \u0026amp; switches specification guide at www.lutron.com\u003cbr\u003e*Set to power module load type\u003cbr\u003e**Set to incandescent load type\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan style=\"font-weight: bold;\"\u003eSources\/ Load Types\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOperates these sources with a smooth continuous Square Law dimming curve:\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eIncandescent (tungsten)\u003c\/li\u003e\n\u003cli\u003eHalogen\u003c\/li\u003e\n\u003cli\u003eMagnetic low-voltage transformer (iron core)\u003c\/li\u003e\n\u003cli\u003eElectronic (solid-state) low-voltage transformer (must be manufacturer approved for reverse-phase control dimming)\u003c\/li\u003e\n\u003cli\u003eNeon\/Cold cathode\u003c\/li\u003e\n\u003cli\u003eLutronR Tu-Wire fluorescent dimming ballasts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eIncandescent and electronic low-voltage sources may be controlled on the same circuit\/control zone. Up to 30% of the unit’s capacity may be used for incandescent lighting.\u003c\/li\u003e\n\u003cli\u003eIncandescent and magnetic low-voltage sources may NOT be controlled on the same circuit\/control zone.\u003c\/li\u003e\n\u003cli\u003ePHPM-PA not for use with non-dim loads. Use switching power module (PHPM-SW-DV-WH) for\u003cbr\u003enon-dim loads.\u003c\/li\u003e\n\u003cli\u003eMinimum load on power module is 10 W.\u003c\/li\u003e\n\u003cli\u003eOutput must be directly connected to the load. Load side switching is not recommended.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable class=\"subpage_table\" cellpadding=\"5\" cellspacing=\"0\" width=\"100%\"\u003e\t\t\n\t\u003ctbody\u003e\n\u003ctr class=\"brown\"\u003e\t\t\t\n    \t\u003ctd valign=\"top\" width=\"30%\"\u003eModel #\u003c\/td\u003e\t\t\t\n        \u003ctd\u003ePHPM-PA-120-WH\u003c\/td\u003e\t\t\n     \u003c\/tr\u003e \n           \n     \u003ctr class=\"brown\"\u003e\t\t\t\n    \t\u003ctd valign=\"top\" width=\"30%\"\u003eType\u003c\/td\u003e\t\t\t\n        \u003ctd\u003ePower Modules\u003cbr\u003e\n\u003c\/td\u003e\t\t\n     \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eControl Power\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e120 V~\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eLoad Power\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e120 V ~\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eCapacity\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eFull 16 A, 1920 W\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eFrequency\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e50 \/ 60 Hz, phase-to-neutral\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eLoad (output) power:\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003ePhase independent of control device\/control voltage.\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eKey Design Features\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cul\u003e\n\u003cli\u003eAutomatically selects between forward phase\/leading edge (e.g., magnetic low-voltage) and reverse phase\/trailing edge (e.g., electronic low-voltage) dimming\/output based on connected load.\u003c\/li\u003e\n\u003cli\u003ePatented RTISS\u003csub\u003eTM\u003c\/sub\u003e circuitry compensates in real time for incoming line voltage variations: Compensates for +\/-2% change in RMS voltage\/cycle and +\/-2% Hz change in frequency\/second.\u003c\/li\u003e\n\u003cli\u003eProvides air-gap off.\u003c\/li\u003e\n\u003cli\u003eModule protects itself during most temporary over-current and over-voltage conditions.\u003c\/li\u003e\n\u003cli\u003eTwo LEDs on front of unit provide diagnostic information (visible when faceplate is removed).\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTerminals\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eEach terminal accepts up to two 12 AWG (2.5 mm2) wires.\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMounting\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cul\u003e\n\u003cli\u003eSurface or recess mount.\u003c\/li\u003e\n\u003cli\u003ePower module is UL tested and approved for use in spaces designed for environmental air handling.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e   \n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46795623629107,"sku":"Lutron-PHPM-PA-120-WH","price":313.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Lutron-PHPM-PA-120-WH-2.jpg?v=1737774573","url":"https:\/\/electricbargainstores.com\/products\/lutron-phpm-pa-120-wh","provider":"Electric Bargain Store","version":"1.0","type":"link"}