Technical Spec
The Firex 10000 carbon monoxide alarm shall be 5” in diameter (12.7 cm) and shall be powered by a 120 VAC, 60 Hz with a 9 volt battery back-up. 100% solid state circuits shall operate over an input range of 100-130 VAC. This alarm shall be rated at no greater than 0.05 amp in standby. Operating temperature shall be between 40°F to 100°F (4.4°C to 37.8°C) and relative humidity between 15%-95%. Item 10000 shall operate independently or is interconnectable with up to 12 smoke alarms and a combination of up to 6 carbon monoxide, or 6 heat alarms for a total of 18 units. Item 10000 can share the interconnect wire of smoke and heat alarms, but the 10000 will remain silent if smoke or heat is detected by the interconnected smoke and heat alarms. Both CO alarms and smoke alarms need to be installed in those areas to be protected. Quick connect pigtail wiring and separate mounting brackets are included with these units to allow surface, junction box or octagon box installation. - EXCLUSIVE Monox® Sensor with True-Test™ Sensor Diagnostics – Verifies that carbon monoxide sensor and electronics are working properly, and warns when the sensor is nearing the end of its service life.
- EXCLUSIVE Automatic Monthly Self-Test – Alarm performs a silent internal system test to verify CO sensor operation.
- EXCLUSIVE True End of Life Replacement Alert – End of service life is detected from the carbon monoxide sensor in the alarm and provides warning that the unit should be replaced.
- EXCLUSIVE Interconnect Test – In an interconnected system, this feature will alarm the local unit first, then quiet the local unit while the remote units alarm.
- Front Loading Battery Door – Eliminates battery handling during installation and allows for safe and convenient battery replacement.
- Battery Pull Tab – Makes installation faster and easier, reducing callbacks due to battery failure. Simply pull tab, close door and press test button.
- Latching LED Alarm Indicator – After a carbon monoxide alarm condition the single RED light on the triggering alarm blinks until reset.
- Smart Quiet™ Trigger Alarm Locator – Pushing test button quiets all alarms EXCEPT the one that triggered the alarm.
- Smart Quiet™ Low Battery Silencer – Silences low battery alert up to 10 hours.
- Quick Quiet™ False Alarm Control – Quiets unwanted carbon monoxide alarms for up to six minutes.
- Dust Cover – Protects from dust, dirt, fumes or other common contaminants during construction, reducing false alarms and callbacks.
- FireX® Compatible – Interconnects with most FireX smoke, heat and CO alarms. (See Technical Specifications section for interconnectable FireX units.)
- Ramp-up Horn – Protects your hearing when testing the alarm by building up the decibel level slowly, giving you time to move away from the horn before the full alarm sequence begins.
Item | 10000 | Model | COE | Weight | 8 oz. | Operating Temperature | 40° - 100°F(4.4°C to 37.8°C) | Interconnect Quantity | Up to 18 FireX devices maximum; FireX smoke alarm items 5000 and 4618 (model FADC), 4518 (model ADC), 4418 (model AD), 4580 (model FAPD), 4480 (model PAD), 4671 (model TPCI), 406 (model G) FireX heat alarm 5700 (model ADH), FireX CO alarm 10000 (model COE), 10400C (model COEA) (up to 6 heat and CO alarms maximum). Not compatable with 7000 (model FADCQ) and 6045 (model COQ8). | Electrical Rating | 120V AC, 60 Hz, 50mA max. | Horn Output | 85 decibels at 10 feet | Listings | UL 2034 | Detection Type | Electrochemical | Humidity Range | 15% to 95% relative humidity |
|