Juno Aculux INIT3 D 08LM WDIM HALR 90CRI 35D FPC 120 ICAT Recessed Lighting 3" Non IC New Construction Housing, 800 Lumens, Warm Dim, 90 CRI, 35 Degree Beam, Phase Cut Dimming, 120V
Juno Aculux INIT3 D 08LM WDIM HALR 90CRI 35D FPC 120 ICAT Recessed Lighting 3" Non IC New Construction Housing, 800 Lumens, Warm Dim, 90 CRI, 35 Degree Beam, Phase Cut Dimming, 120V
 
Alternative Views:


Our Price: $169.59
Request Large Quantity Quote


Usually Ships in 3-5 business days. Urgent Project? Contact Us.




Model: JUNO-INIT3-D-33749
Qty:

Technical Spec Downloads
 
Technical Spec
PRODUCT FAMILY SPECIFICATIONS
FIELD INTERCHANGEABLE LED LIGHT ENGINE
  • <2SDCM Binning
  • 2700K | 3000K | 3500K | 4000K CCT
  • 80+ CRI available for all CCTs
  • 90+ CRI available for 2700K, 3000K, 3500K
  • WarmDim mimics halogen, with CCT shifting from 3000K to 1800K when dimmed.
  • Future proof and easy to maintain - serviceable from below the ceiling
OPTICAL SYSTEM
  • 45 degrees visual cutoff to source and source image
  • Field interchangeable TIR optics from 18 degrees FWHM to 50 degrees FWHM provide smooth, striation-free beams
  • Accommodates 1 beam control lens or filter
  • UGR is zero for fixtures aimed at nadir with a cut-off equal to or less than 60deg, per CIE 117-1996 Discomfort Glare in Interior Lighting.
FIELD REPLACEABLE DRIVER
  • Accommodates 120-277V input and multiple control protocols
  • Dims without perceived flicker to <1% depending on driver specified
  • Field replaceable from below the ceiling
  • >0.9 Power Factor
BUY AMERICAN ACT
  • This product is assembled in the USA and meets the Buy America(n) government procurement requirements under FAR, DFARS and DOT regulations.
WARRANTY & RATED LIFE
  • LED is rated for >50,000 hours at 70% lumen maintenance
  • 5- year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed.
EMERGENCY BATTERY (ADD-ON OPTION)
  • Provides a minimum of 400 lumens (3000K, 80CRI) for minimum duration of 90 minutes.
  • Above ceiling access required.
  • Supplied with remote test switch
  • E5WT20R option is CEC T20 Compliant
CEILING THICKNESS
  • Accommodates 1/2" to 1 1/2" ceiling thickness
INSTALLATION
  • New construction or remodel (install from below) are available.
  • Residential style bar hanger provided with all new construction housings except when specified with emergency battery.
  • Vertically adjustable mounting brackets (butterfly brackets) are provided on non-ICAT new construction housings.
JUNCTION BOX
  • New construction housings are rated for (4) No. 12 AWG 90°C through branch circuit conductors (excludes ECOD drivers)
  • New Construction housings include (6) 1/2", (1) 3/4", (4) Nonmetallic sheathed cable knock-outs.
  • Remodel housings feature (8) 1/2" knockouts suitable for daisy chain wiring.
  • Push-in electrical connectors for field connections.
CODES & LABELS
  • UL & cUL listed for through branch wiring (excludes ECOD), damp location. Listed for wet location with WSOL option. NT3SHDBV option is IP65 rated and can be used to comply with dead front and/or non-conductive lighting electrical code requirements.
  • ICAT meets energy code air leakage requirements per ASTM E283
  • ENERGY STAR certified with NT3DP and NT3DBV (excluding 50D beam) trims for static white @ 80CRI and NT3DP trims (excluding: BS finish, ECOD driver) for warmdim.
  • Title 24, Part 6: JA-8 Compliant with 90CRI and ICAT. Refer to CEC T24 website for compatible trims.
  • ICAT housings are rated for direct contact with insulation
  • 04LM ICAT & 08LM ICAT housings* are rated for direct contact with insulation, including open and closed cell spray foam with a maximum R-value of 7.2R/in. This allows use in ceiling cavities insulated up to R60.
  • 12LM ICAT housings* are rated for direct contact with insulation, including open cell spray foam with a maximum R-value of 3.8R/in. They are not suitable for use with closed cell spray foam.
  • NT3SHDBV option can be used to comply with dead front and/ or non-conductive lighting electrical code requirements. Flanged (SF) version is certified to IP65
  • Note: Options: "ECOS2", "ECOD" & "WDIM HALR" are excluded and not suitable for use with spray foam insulation. 12LM ICAT housings are only suitable for use with open cell spray foam, and not suitable for use with closed cell.


Share your knowledge of this product. Be the first to write a review »

Browse for more products in the same category as this item:

BRANDS > Juno Lighting > Juno Recessed Lighting > Juno Aculux Recessed Lighting 3 inch Aperture > Juno Aculux Recessed Lighting 3 inch LED Housings > Juno Aculux INIT3 D New Construction Housing
We Our Customers!

Thanks for shopping with us today

Click here to get a promo code for 10% off your next order

How can we help you?
Live Chat